Silicon PIN array-based charge measurement detector for HERD beam test

被引:0
|
作者
Gong, Ke [1 ,2 ]
Qiao, Rui [1 ]
Peng, Wenxi [1 ,2 ]
Lu, Bin [1 ]
Liu, Yaqing [1 ]
Guo, Dongya [1 ]
Lu, Ruosi [1 ]
Liu, Xuan [1 ,3 ]
Zhang, Zhen [1 ,3 ]
Zhang, Jiahe [1 ,3 ]
Bao, Tianwei [1 ]
Dong, Yongwei [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, 19B Yuquan Rd, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, 1 Yanqihu East Rd, Beijing 101408, Peoples R China
[3] North China Univ Technol, 5 Jinyuanzhuang Rd, Beijing 100144, Peoples R China
基金
中国国家自然科学基金;
关键词
Cosmic ray; PID; HERD; Charge measurement; PLASTIC SCINTILLATOR DETECTOR;
D O I
10.1007/s41605-024-00465-w
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
PurposeThe high-energy cosmic radiation detection (HERD) is a dedicated space cosmic ray detector, planned to be launched and installed on the China Space Station (CSS) around 2027. One of the main goals of HERD is to measure the composition and energy spectra of cosmic rays (CR) with energies as high as several PeV by using silicon charge detectors (SCD) (Altomare et al. in The silicon charge detector of the high energy cosmic radiation detection facility, 2023), plastic scintillator detectors (PSD) (Kyratzis et al. in Proceedings of Sc. (ICRC2021), vol. 651, 2021), and 3D calorimeters (CALO) (Liu et al. in J Instrum 18(09):09002, 2023). To assess HERD's charge measurement capability during the beam test, a particle identification detector (PID) with a large dynamic range is required.MethodsA Si-PIN-based PID detector is conceptualized and manufactured. It is composed of four layers, each containing 30 Si-PIN sensors. In four IDE1160 ASICs, the signals from the Si-PIN arrays are preamplified, shaped, peak-held, and serially read out by four IDE1160 ASICs. A DAQ system is created to digitize the analog signals from ASICs, organize the data package, and transfer it to the host computer.Results and conclusionBefore going to the beam test, the dynamic range, linearity, pedestal, and noise level of each channel in PID were studied at home. The dynamic range is 0 to +5 pC, the linearity is better than 2%, and the RMSE (Root Mean Square Error) of the pedestal is about 1 fC. The preliminary beam test results show that PID is capable of detecting heavy ions from Z=4\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$Z=4$$\end{document} (Be) to Z=31\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$Z=31$$\end{document} (Ga), and the charge resolution is better than 0.3 charge units (c.u.).
引用
收藏
页码:1480 / 1485
页数:6
相关论文
共 50 条
  • [31] Scintillation fiber array detector for measurement of neutron beam profile
    Kim, Chong
    Hong, Byungsik
    Jo, Mihee
    Lee, Kyong Sei
    Sim, Kwang-Souk
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 276 - 280
  • [32] OPTICAL TRANSFER-FUNCTION MEASUREMENT WITH A SILICON ARRAY DETECTOR
    MEHL, CR
    FISHER, JJ
    ROBERTS, DE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1982, 72 (12) : 1781 - 1781
  • [33] Uncertainty of array-based measurement of radiated and absorbed sound intensity
    Moschioni, Giovanni
    Saggin, Bortolino
    Tarabini, Marco
    Hald, Jorgen
    Morkholt, Jakob
    APPLIED ACOUSTICS, 2014, 78 : 51 - 58
  • [34] Laser measurement of absolute charge collection efficiency of a silicon detector
    Bazant, Pavel
    Broz, Jan
    Dolezal, Zdenek
    Drasal, Zbynek
    Kodys, Peter
    Kvasnicka, Peter
    Reznicek, Pavel
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 306 - 309
  • [35] A 16-CHANNEL CHARGE SENSITIVE AMPLIFIER IC FOR A PIN PHOTODIODE-ARRAY BASED PET DETECTOR MODULE
    MOSES, WW
    KIPNIS, I
    HO, MH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1469 - 1472
  • [36] Silicon detector array for radioactive beam experiments at HIRFL-RIBLL
    Fang-Fang Duan
    Yan-Yun Yang
    Bi-Tao Hu
    Jian-Song Wang
    Zhi-Hao Gao
    Xing-Quan Liu
    Dipikap Patel
    Peng Ma
    Jun-Bing Ma
    Shu-Ya Jin
    Zhen Bai
    Qiang Hu
    Guo Yang
    Xin-Xin Sun
    Nan-Ru Ma
    Li-Jie Sun
    Hui-Ming Jia
    Xin-Xing Xu
    Cheng-Jian Lin
    Nuclear Science and Techniques, 2018, 29
  • [37] Silicon detector array for radioactive beam experiments at HIRFL-RIBLL
    Fang-Fang Duan
    Yan-Yun Yang
    Bi-Tao Hu
    Jian-Song Wang
    Zhi-Hao Gao
    Xing-Quan Liu
    Dipikap Patel
    Peng Ma
    Jun-Bing Ma
    Shu-Ya Jin
    Zhen Bai
    Qiang Hu
    Guo Yang
    Xin-Xin Sun
    Nan-Ru Ma
    Li-Jie Sun
    Hui-Ming Jia
    Xin-Xing Xu
    Cheng-Jian Lin
    NuclearScienceandTechniques, 2018, 29 (11) : 76 - 83
  • [38] Silicon detector array for radioactive beam experiments at HIRFL-RIBLL
    Duan, Fang-Fang
    Yang, Yan-Yun
    Hu, Bi-Tao
    Wang, Jian-Song
    Gao, Zhi-Hao
    Liu, Xing-Quan
    Patel, Dipikap
    Ma, Peng
    Ma, Jun-Bing
    Jin, Shu-Ya
    Bai, Zhen
    Hu, Qiang
    Yang, Guo
    Sun, Xin-Xin
    Ma, Nan-Ru
    Sun, Li-Jie
    Jia, Hui-Ming
    Xu, Xin-Xing
    Lin, Cheng-Jian
    NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (11)
  • [39] TEST BEAM STUDIES OF A SILICON MICROSTRIP VERTEX DETECTOR.
    Karchin, P.E.
    Hale, D.L.
    Morrison, R.J.
    Witherell, M.S.
    Sokoloff, M.D.
    Kiang, A.
    Kumar, B.R.
    Martin, J.F.
    Sarabura, M.
    1600, (NS-32):
  • [40] Beam test results of the irradiated silicon drift detector for ALICE
    Kushpil, S.
    Crescio, E.
    Glubellino, P.
    Idzik, M.
    Kolozhvari, A.
    Kushpil, V.
    Martinez, M. I.
    Mazza, G.
    Mazzoni, A.
    Meddi, F.
    Nouais, D.
    Petracek, V.
    Piemonte, C.
    Rashevsky, A.
    Riccati, L.
    Rivetti, A.
    Tosello, F.
    Vacchi, A.
    Wheadon, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (01): : 94 - 99