Robot-assisted surgery for dental implant placement: A narrative review

被引:4
|
作者
Wang, Miaozhen [1 ,2 ,3 ,4 ]
Liu, Feng [1 ,2 ,3 ,4 ,6 ]
Zhao, Xu [1 ,2 ,3 ,4 ]
Wu, Yuwei [2 ,3 ,4 ,5 ]
机构
[1] Peking Univ Sch &N Hosp Stomatol, Clin Div 1, Beijing, Peoples R China
[2] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[3] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[4] Beijing Key Lab Digital Stomatol, Beijing, Peoples R China
[5] Peking Univ Sch & Hosp Stomatol, Clin Div 2, Beijing, Peoples R China
[6] 37 Xishiku St, Beijing 100034, Peoples R China
关键词
Accuracy; Computer-assisted surgery; Robot-assisted surgery; Implant placement; Digital dentistry; Robotic surgical procedure; BEAM COMPUTED-TOMOGRAPHY; ACCURACY; NAVIGATION; COMPLICATIONS; TECHNOLOGY; DENTISTRY;
D O I
10.1016/j.jdent.2024.105034
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To determine the current status and accuracy of robotic computer-assisted implant surgery (CAIS) applications by examining the associated clinical and experimental outcomes. Data and sources: PubMed, Medline, and Cochrane Library databases were searched for relevant studies published between January 2000 and November 2023, and focusing on robotic CAIS in dental implant surgery. All search results were then manually reviewed to identify only the pertinent articles. Only in vitro and clinical studies were included in this narrative review, with implant placement accuracy considered the main outcome. Result: Based on our inclusion and exclusion criteria, we included 21 studies (with 1085 implant sites); of them, 8 were clinical studies, 12 were in vitro studies, and 1 included both an in vitro study and a case series. The ranges of the mean implant shoulder, apical, and angular deviations were respectively 0.43-1.04 mm, 0.53-1.06 mm, and 0.77 degrees-3.77 degrees in the clinical studies and 0.23-1.04 mm, 0.24-2.13 mm, and 0.43 degrees-3.78 degrees in the in vitro studies, respectively. Conclusion: The accuracy of robotic CAIS in dental implant procedures appears to be within the clinically acceptable ranges. However, further relevant clinical trials validating the existing evidence are needed. Clinical significance: Robotic CAIS can achieve clinically acceptable implant placement accuracy. This innovative technology may improve the precision and success rates of dental implant procedures, with benefit for surgeons and patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Robot-assisted dental implant surgery procedure: A literature review
    Bahrami, Rashin
    Pourhajibagher, Maryam
    Nikparto, Nariman
    Bahador, Abbas
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (03) : 1359 - 1368
  • [2] MOPRP: Multiobjective optimization on preoperative robot placement for robot-assisted dental implant surgery
    Wang, Yan
    Wang, Wei
    Cai, Yueri
    ADVANCES IN MECHANICAL ENGINEERING, 2025, 17 (04)
  • [3] Guided innovations: Robot-assisted dental implant surgery
    Rawal, Sundeep
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (05): : 673 - 674
  • [4] Current Status and Future Perspectives of Robot-Assisted Dental Implant Surgery
    Huang, Shuang
    Wang, Zhongli
    Li, Miaomiao
    Song, Yingli
    Li, Yuezhi
    INTERNATIONAL DENTAL JOURNAL, 2025, 75 (03) : 1608 - 1620
  • [5] Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies
    Jain, Saurabh
    Sayed, Mohammed E.
    Ibraheem, Wael I.
    Ageeli, Abrar A.
    Gandhi, Sumir
    Jokhadar, Hossam F.
    Alresayes, Saad Saleh
    Alqarni, Hatem
    Alshehri, Abdullah Hasan
    Huthan, Halah Mohammed
    Alami, Atheer
    Al Wadei, Mohammed Hussain Dafer
    Aljabri, Yahya
    MEDICINA-LITHUANIA, 2024, 60 (01):
  • [6] Influence of dental implant clinical experience on the accuracy of robot-assisted immediate implant placement: an in vitro study
    Wang, Yunxiao
    Wang, Yulan
    Yu, Shimin
    Han, Litian
    Feng, Yi
    Miron, Richard J.
    Yan, Qi
    Zhang, Yufeng
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (09)
  • [7] Technologic advances in robot-assisted nephron sparing surgery: a narrative review
    Thakker, Parth Udayan
    O'Rourke Jr, Timothy Kirk
    Hemal, Ashok Kumar
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2023, 12 (07) : 1184 - 1198
  • [8] Accuracy of robot-assisted implant surgery versus freehand placement: a retrospective clinical study
    Younis, Hamza
    Xu, Boya
    Acharya, Kiran
    He, Longlong
    Du, Liangzhi
    Elayah, Sadam Ahmed
    Chang, Xiaofeng
    Lv, Chengpeng
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)
  • [9] Preoperative Planning Framework for Robot-Assisted Dental Implant Surgery: Finite-Parameter Surrogate Model and Optimization of Instrument Placement
    Wang, Yan
    Wang, Wei
    Cai, Yueri
    Zhao, Qiming
    Wang, Yuyang
    BIOENGINEERING-BASEL, 2023, 10 (08):
  • [10] Ergonomics in robot-assisted surgery in comparison to open or conventional laparoendoscopic surgery: A narrative review
    Mueller, Dolores T.
    Ahn, Juliane
    Brunner, Stefanie
    Poggemeier, Julia
    Storms, Christian
    Reisewitz, Alissa
    Schmidt, Thomas
    Bruns, Christiane J.
    Fuchs, Hans F.
    INTERNATIONAL JOURNAL OF ABDOMINAL WALL AND HERNIA SURGERY, 2023, 6 (02) : 61 - 66