Impact of scatter radiation on spectral quantification performance of first- and second-generation dual-layer spectral computed tomography

被引:0
|
作者
Salazar, Edgar [1 ,2 ]
Liu, Leening P. [1 ,2 ]
Perkins, Amy E. [3 ]
Halliburton, Sandra S. [3 ]
Shapira, Nadav [1 ]
Litt, Harold I. [1 ]
Noel, Peter B. [1 ]
机构
[1] Univ Penn, Dept Radiol, 3620 Hamilton Walk, Philadelphia, PA 19104 USA
[2] Univ Privada Boliviana, Dept Engn & Architecture, La Paz, Bolivia
[3] Philips Healthcare, Orange Village, OH USA
来源
基金
美国国家卫生研究院;
关键词
Compton scattering artifacts; dual-layer spectral CT; quantitative CT; spectral computed tomography;
D O I
10.1002/acm2.14383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems.MethodA phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50 versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported.ResultsAn experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45 and 0.33 mg/mL for the first and second-generation DLCT, respectively).ConclusionThe implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Late iodine enhancement and myocardial extracellular volume quantification in cardiac amyloidosis by using dual-energy cardiac computed tomography performed on a dual-layer spectral detector scanner
    Oda, Seitaro
    Nakaura, Takeshi
    Utsunomiya, Daisuke
    Hirakawa, Kyoko
    Takashio, Seiji
    Izumiya, Yasuhiro
    Tsujita, Kenichi
    Hata, Hiroyuki
    Ando, Yukio
    Yamashita, Yasuyuki
    AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2018, 25 (02): : 137 - 138
  • [42] On-Chip Comparison of the Performance of First- and Second-Generation Micropillar Array Columns
    Vankeerberghen, Bert
    Op de Beeck, Jeff
    Desmet, Gert
    ANALYTICAL CHEMISTRY, 2023, 95 (37) : 13822 - 13828
  • [43] The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media
    Huang, Xin
    Gao, Sizhe
    Ma, Yue
    Lu, Xiaomei
    Jia, Zheng
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (03) : 592 - 603
  • [44] Application of Dual-Layer Spectral-Detector Computed Tomography Angiography in Identifying Symptomatic Carotid Atherosclerosis: A Prospective Observational Study
    Zhang, Jia
    Li, Sijia
    Wu, Lei
    Wang, Haoyuan
    Wang, Chuanying
    Zhou, Yinan
    Sui, Binbin
    Zhao, Xingquan
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (06): : e032665
  • [45] A prediction model based on dual-layer spectral detector computed tomography for distinguishing nonluminal from luminal invasive breast cancer
    Liu, Jun
    Wang, Lanlan
    Ai, Zhaodong
    Jian, Lian
    Yang, Ming
    Liu, Siye
    Yu, Xiaoping
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 8672 - 8685
  • [46] Individual trabecula segmentation validation in first- and second-generation high-resolution peripheral computed tomography compared to micro-computed tomography in the distal radius and tibia
    Dinescu, Andreea Teodora
    Zhou, Bin
    Hu, Yizhong Jenny
    Agarwal, Sanchita
    Shane, Elizabeth
    Guo, Xiang-Dong Edward
    JBMR PLUS, 2024, 8 (03)
  • [47] Dual-Layer Spectral Detector Computed Tomography Quantitative Parameters: A Potential Tool for Lymph Node Activity Determination in Lymphoma Patients
    Chen, Hebing
    Fang, Yuxiang
    Gu, Jin
    Sun, Peng
    Yang, Lian
    Pan, Feng
    Wu, Hongying
    Ye, Tianhe
    DIAGNOSTICS, 2024, 14 (02)
  • [48] Quantitative parameters of dual-layer spectral detector computed tomography for evaluating differentiation grade and lymphovascular and perineural invasion in colorectal adenocarcinoma
    Chen, Jinghua
    Ni, Lei
    Gong, Jingjing
    Wu, Jie
    Qian, Tingting
    Wang, Mengjia
    Huang, Jian
    Liu, Kefu
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 178
  • [49] Quantitative analysis of late iodine enhancement using dual-layer spectral detector computed tomography: comparison with magnetic resonance imaging
    Liu, Peijun
    Lin, Lu
    Xu, Cheng
    Han, Yechen
    Lin, Xue
    Hou, Yang
    Lu, Xiaomei
    Vembar, Mani
    Jin, Zhengyu
    Wang, Yining
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 310 - 320
  • [50] Low Dose Iodinated Contrast Material and Radiation for Virtual Monochromatic Imaging in Craniocervical Dual-Layer Spectral Detector Computed Tomography Angiography: A Prospective and Randomized Study
    Zhou, Xiuzhi
    Cui, Manman
    Liu, Yan
    Wu, Yuanyuan
    Hu, Dongliang
    Zhai, Duchang
    Qin, Mingyu
    Shen, Junkang
    Ju, Shenghong
    Fan, Guohua
    Cai, Wu
    ACADEMIC RADIOLOGY, 2024, 31 (06) : 2501 - 2510