Impact of scatter radiation on spectral quantification performance of first- and second-generation dual-layer spectral computed tomography

被引:0
|
作者
Salazar, Edgar [1 ,2 ]
Liu, Leening P. [1 ,2 ]
Perkins, Amy E. [3 ]
Halliburton, Sandra S. [3 ]
Shapira, Nadav [1 ]
Litt, Harold I. [1 ]
Noel, Peter B. [1 ]
机构
[1] Univ Penn, Dept Radiol, 3620 Hamilton Walk, Philadelphia, PA 19104 USA
[2] Univ Privada Boliviana, Dept Engn & Architecture, La Paz, Bolivia
[3] Philips Healthcare, Orange Village, OH USA
来源
基金
美国国家卫生研究院;
关键词
Compton scattering artifacts; dual-layer spectral CT; quantitative CT; spectral computed tomography;
D O I
10.1002/acm2.14383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems.MethodA phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50 versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported.ResultsAn experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45 and 0.33 mg/mL for the first and second-generation DLCT, respectively).ConclusionThe implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Dual-layer spectral computed tomography aortography using a seventy-five-percent-reduced iodine dose protocol and multiparameter spectral imaging: comparison with conventional computed tomography imaging
    Wang, Aijie
    Li, Wanjiang
    Huang, Wenyu
    Luo, Mao
    Xiao, Wendan
    Qin, Chaoyi
    Dong, Shushan
    Liu, Haiwei
    Li, Zhenlin
    Diao, Kaiyue
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (10) : 6456 - +
  • [32] Phantom-based quantification of the spectral accuracy in dual-layer spectral CT for pediatric imaging at 100 kVp
    Meyer, Sebastian
    Liu, Leening P.
    Litt, Harold, I
    Halliburton, Sandra S.
    Shapira, Nadav
    Noel, Peter B.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (02) : 924 - 934
  • [33] Diagnostic Performance of Dual-Layer Computed Tomography for Deep Vein Thrombosis in Indirect Computed Tomography Venography
    Tanoue, Shota
    Nakaura, Takeshi
    Iyama, Yuji
    Iyama, Ayumi
    Nagayama, Yasunori
    Yoshida, Morikatsu
    Yamashita, Yasuyuki
    CIRCULATION JOURNAL, 2020, 84 (04) : 636 - 641
  • [34] Iodine concentration, HU accuracy, and metal artifacts evaluation on second-generation dual-layer spectral detector CT images with metal implants: a phantom study
    Zhang, Xinming
    Li, Hanwei
    Wang, Haowen
    Liu, Xiaomin
    Deng, Weiwei
    Zhong, Jianqiu
    Fan, Litian
    Ling, Qingqing
    Hu, Debin
    Qi, Hongliang
    Chen, Hongwen
    ACTA RADIOLOGICA, 2024, 65 (09) : 1030 - 1038
  • [35] Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography
    Ghandour, Abed
    Sher, Andrew
    Rassouli, Negin
    Dhanantwari, Amar
    Rajiah, Prabhakar
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 858 - 865
  • [36] Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images
    Sauter, Andreas P.
    Muenzel, Daniela
    Dangelmaier, Julia
    Braren, Rickmer
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Noel, Peter B.
    Fingerle, Alexander A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 104 : 108 - 114
  • [37] Evaluation of colorectal liver metastases using virtual monoenergetic images obtained from dual-layer spectral computed tomography
    Bae, Jae Seok
    Yoon, Jeong Hee
    Kim, Jae Hyun
    Han, Seungchul
    Park, Sungeun
    Kim, Se Woo
    ABDOMINAL RADIOLOGY, 2024, : 1624 - 1632
  • [38] The preoperative prediction of lymph node metastasis of resectable pancreatic ductal adenocarcinoma using dual-layer spectral computed tomography
    Chen, Yi
    Xie, Tiansong
    Chen, Lei
    Zhang, Zehua
    Wang, Yu
    Zhou, Zhengrong
    Liu, Wei
    EUROPEAN RADIOLOGY, 2024, : 2692 - 2701
  • [39] Clinical Usefulness of Dual-Energy Cardiac Computed Tomography in Acute Coronary Syndrome Using a Dual-Layer Spectral Detector Scanner
    Nishihara, Taiki
    Oda, Seitaro
    Sueta, Daisuke
    Izumiya, Yasuhiro
    Kaikita, Koichi
    Tsujita, Kenichi
    Utsunomiya, Daisuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (02)
  • [40] SNR performance comparison of dual-layer detector and dual-kVp spectral CT
    Heismann, B. J.
    Wirth, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3820 - 3822