Impact of scatter radiation on spectral quantification performance of first- and second-generation dual-layer spectral computed tomography

被引:0
|
作者
Salazar, Edgar [1 ,2 ]
Liu, Leening P. [1 ,2 ]
Perkins, Amy E. [3 ]
Halliburton, Sandra S. [3 ]
Shapira, Nadav [1 ]
Litt, Harold I. [1 ]
Noel, Peter B. [1 ]
机构
[1] Univ Penn, Dept Radiol, 3620 Hamilton Walk, Philadelphia, PA 19104 USA
[2] Univ Privada Boliviana, Dept Engn & Architecture, La Paz, Bolivia
[3] Philips Healthcare, Orange Village, OH USA
来源
基金
美国国家卫生研究院;
关键词
Compton scattering artifacts; dual-layer spectral CT; quantitative CT; spectral computed tomography;
D O I
10.1002/acm2.14383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems.MethodA phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50 versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported.ResultsAn experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45 and 0.33 mg/mL for the first and second-generation DLCT, respectively).ConclusionThe implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Bone mineral density measurements in vertebral specimens and phantoms using dual-layer spectral computed tomography
    Mei, Kai
    Schwaiger, Benedikt J.
    Kopp, Felix K.
    Ehn, Sebastian
    Gersing, Alexandra S.
    Kirschke, Jan S.
    Muenzel, Daniela
    Fingerle, Alexander A.
    Rummeny, Ernst J.
    Pfeiffer, Franz
    Baum, Thomas
    Noel, Peter B.
    SCIENTIFIC REPORTS, 2017, 7
  • [22] Detection of axillary lymph node metastasis in breast cancer using dual-layer spectral computed tomography
    Li, Huijun
    Wang, Huan
    Chen, Fangfang
    Gao, Lei
    Zhou, Yurong
    Zhou, Zhou
    Huang, Jinbai
    Xu, Liying
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [23] Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing
    Taguchi, Narumi
    Oda, Seitaro
    Imuta, Masanori
    Yamamura, Sadahiro
    Yokota, Yasuhiro
    Nakaura, Takeshi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Baba, Hideo
    Yamashita, Yasuyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 7 - 12
  • [24] Dual-layer spectral detector computed tomography multiparameter machine learning model for prediction of invasive lung adenocarcinoma
    Wan, Jiayu
    Lin, Xue
    Wang, Zhaokai
    Sun, Peng
    Gui, Shen
    Ye, Tianhe
    Fan, Qianqian
    Liu, Weiwei
    Pan, Feng
    Yang, Bo
    Geng, Xiaotong
    Quan, Zhen
    Yang, Lian
    TRANSLATIONAL LUNG CANCER RESEARCH, 2025, 14 (02)
  • [25] Usefulness and limitations of dual-layer spectral detector computed tomography for diagnosing biliary stones not detected by conventional computed tomography: a report of three cases
    Saito H.
    Noda K.
    Ogasawara K.
    Atsuji S.
    Takaoka H.
    Kajihara H.
    Nasu J.
    Morishita S.
    Matsushita I.
    Katahira K.
    Clinical Journal of Gastroenterology, 2018, 11 (2) : 172 - 177
  • [26] Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading
    Mu, Ronghua
    Meng, Zhuoni
    Guo, Zixuan
    Qin, Xiaoyan
    Huang, Guangyi
    Yang, Xuri
    Jin, Hui
    Yang, Peng
    Zhang, Xiaodi
    Zhu, Xiqi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, : 4601 - 4611
  • [27] Application of dual-layer spectral detector computed tomography to evaluate the expression of Ki-67 in colorectal cancer
    Wang, Yu-Li
    Zhang, Han-Wen
    Mo, Yong-Qian
    Zhong, Hua
    Liu, Wei-Ming
    Lei, Yi
    Lin, Fan
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2022, 85 (05) : 610 - 616
  • [28] Calcium decomposition and phantomless bone mineral density measurements using dual-layer based spectral computed tomography
    Mei, Kai
    Schwaiger, Benedikt J.
    Kopp, Felix K.
    Ehn, Sebastian
    Gersing, Alexandra S.
    Kirschke, Jan S.
    Muenzel, Daniela
    Fingerle, Alexander A.
    Rummeny, Ernst J.
    Pfeiffer, Franz
    Baum, Thomas
    Noel, Peter B.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [29] Non-Invasive Imaging in Pulmonary Hypertension - Comprehensive Assessment Using Dual-Layer Spectral Computed Tomography -
    Oda, Seitaro
    Kidoh, Masafumi
    Nagayama, Yasunori
    Nakaura, Takeshi
    Hirakawa, Kyoko
    Yamamoto, Eiichiro
    Tsujita, Kenichi
    Hirai, Toshinori
    CIRCULATION JOURNAL, 2021, 85 (03) : 316 - +
  • [30] A Retrospectively Study: Diagnosis of Pathological Types of Malignant Lung Tumors by Dual-layer Detector Spectral Computed Tomography
    Ma, Xia
    Xu, Ming
    Tian, Xiao-Juan
    Liu, Yong-Li
    Zhang, Xin-Ri
    Qiao, Ying
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21