Experimental and numerical study on the behavior of high strength Q960 steel columns after fire exposure

被引:4
|
作者
Wang, Weiyong [1 ,2 ]
Li, Yameng [1 ]
Wang, Zhiruoyu [3 ]
Pang, Shiyun [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Key Lab New Technol Construction Cities Mt Area, Minist Educ, Chongqing 400045, Peoples R China
[3] Univ Queensland, Adv Engn Bldg, St Lucia, Qld 4072, Australia
关键词
High strength q960 steel; Post to high temperature; Axial compression load capacity; Test and finite element analysis; DESIGN;
D O I
10.1016/j.tws.2024.111748
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-strength steel exhibits extensive potential in large-span buildings and bridges. Therefore, it is of great significance to clarify its mechanical properties particularly in the realm of post -fire building repair and reconstruction, making it imperative to elucidate its bearing capacity after exposure to elevated temperatures. To comprehensively investigate the overall stability of high-strength Q960 steel columns under high-temperature conditions, a series of axial compression bearing capacity tests are conducted on eight Q960 steel columns-four of which featured H-shaped sections and the remaining four being box-shaped sections. The design of these members considered the effects of slenderness ratio and temperature. At the same time, the residual stress and geometric initial defects of the steel column were measured. Furthermore, the axial compression model for Q960 steel columns, encompassing both room and high-temperature scenarios, was established using the ABAQUS finite element software. This model duly accounted for the influence of residual stress and geometric initial defects. Subsequently, the test outcomes, encompassing horizontal and vertical displacements, ultimate bearing capacity, and failure mode, were compared with the results obtained from finite element analysis. This comparison serves to validate the accuracy of the model while facilitating parameter analysis. The results based on both the finite element analysis and experimental findings, indicate that when employing the Chinese code GB 50,017-2017, the stability coefficient calculation for Q960 steel columns following high-temperature exposure yields satisfactory safety margins. In light of these findings, a calculation method is proposed to accurately predict the stability coefficient of Q960 steel columns in the aftermath of high-temperature conditions, thus offering a reliable approach for assessing the stability bearing capacity of such columns in such scenarios. By comparing with EN 1993-1-12 and ANSI/AISC 360-22, it is found that EN 1993-1-12 has a better prediction effect, while ANSI/AISC 360-22 is conservative when the slenderness ratio is small.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] An Experimental and Numerical Study on the Behavior of High Strength Concrete Columns in Fire Subjected to High Restraint
    Ali, Faris
    Nadjai, Ali
    Choi, S.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2010, 1 (01) : 1 - 16
  • [22] Numerical and experimental investigation of the behavior of high strength concrete columns in fire
    Ali, Faris
    Nadjai, Ali
    Choi, S.
    ENGINEERING STRUCTURES, 2010, 32 (05) : 1236 - 1243
  • [23] Experimental and numerical study on behaviour of extended end-plate connections with Q960 steel at elevated temperature
    Wang, Weiyong
    Qian, Zhenghao
    Zhang, Yifa
    Wang, Zhiruoyu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 213
  • [24] Experimental and numerical investigation of S700 high strength steel CHS beam-columns after exposure to fire
    Zhong, Yukai
    Zhao, Ou
    Gardner, Leroy
    THIN-WALLED STRUCTURES, 2022, 175
  • [25] Experimental study on the post-fire cyclic behavior of Q960E ultra-high-strength structural steel
    Ding, Miao
    Shen, Le
    Ge, Yi-Qing
    Yang, Bo
    Zhao, Ming-Shan
    Ran, Chun-Hua
    Chiew, Sing-Ping
    THIN-WALLED STRUCTURES, 2023, 191
  • [26] Experimental and Numerical Study on High Strength Steel Endplate Connections after Fire
    Qiang, Xuhong
    Jiang, Xu
    Bijlaard, Frans S. K.
    Kolstein, Henk
    STRUCTURES IN FIRE, 2016, : 443 - 451
  • [27] Experimental study on fire resistance of axially restrained high strength Q460 steel columns
    Wang, Weiyong
    Ge, Yong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (08): : 116 - 122
  • [28] Characterization of the stress-state dependent ductile fracture behavior for Q960 ultra-high-strength structural steel
    Shang, Mingxu
    Yang, Hua
    Muenstermann, Sebastian
    THIN-WALLED STRUCTURES, 2024, 205
  • [29] Experimental study on residual capacities of axially restrained high strength steel columns after fire
    Li G.
    Song L.
    Miao J.
    Miao, Jiarong (jiarongmiao@tongji.edu.cn), 1600, Science Press (41): : 79 - 86
  • [30] Study of fire resistance of high strength Q460 steel columns
    Liu, Bing
    Wang, Weiyong
    Li, Guoqiang
    Dai, Guoxin
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2012, 45 (09): : 19 - 26