Experimental and numerical study on the behavior of high strength Q960 steel columns after fire exposure

被引:4
|
作者
Wang, Weiyong [1 ,2 ]
Li, Yameng [1 ]
Wang, Zhiruoyu [3 ]
Pang, Shiyun [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Key Lab New Technol Construction Cities Mt Area, Minist Educ, Chongqing 400045, Peoples R China
[3] Univ Queensland, Adv Engn Bldg, St Lucia, Qld 4072, Australia
关键词
High strength q960 steel; Post to high temperature; Axial compression load capacity; Test and finite element analysis; DESIGN;
D O I
10.1016/j.tws.2024.111748
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-strength steel exhibits extensive potential in large-span buildings and bridges. Therefore, it is of great significance to clarify its mechanical properties particularly in the realm of post -fire building repair and reconstruction, making it imperative to elucidate its bearing capacity after exposure to elevated temperatures. To comprehensively investigate the overall stability of high-strength Q960 steel columns under high-temperature conditions, a series of axial compression bearing capacity tests are conducted on eight Q960 steel columns-four of which featured H-shaped sections and the remaining four being box-shaped sections. The design of these members considered the effects of slenderness ratio and temperature. At the same time, the residual stress and geometric initial defects of the steel column were measured. Furthermore, the axial compression model for Q960 steel columns, encompassing both room and high-temperature scenarios, was established using the ABAQUS finite element software. This model duly accounted for the influence of residual stress and geometric initial defects. Subsequently, the test outcomes, encompassing horizontal and vertical displacements, ultimate bearing capacity, and failure mode, were compared with the results obtained from finite element analysis. This comparison serves to validate the accuracy of the model while facilitating parameter analysis. The results based on both the finite element analysis and experimental findings, indicate that when employing the Chinese code GB 50,017-2017, the stability coefficient calculation for Q960 steel columns following high-temperature exposure yields satisfactory safety margins. In light of these findings, a calculation method is proposed to accurately predict the stability coefficient of Q960 steel columns in the aftermath of high-temperature conditions, thus offering a reliable approach for assessing the stability bearing capacity of such columns in such scenarios. By comparing with EN 1993-1-12 and ANSI/AISC 360-22, it is found that EN 1993-1-12 has a better prediction effect, while ANSI/AISC 360-22 is conservative when the slenderness ratio is small.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Experimental Investigation on the Local Buckling Behavior of 960 MPa High Strength Steel Welded Section Stub Columns
    Shi, Gang
    Zhou, Wenjing
    Lin, Cuocuo
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (03) : 423 - 437
  • [42] Experimental study on behavior of restrained high strength Q690 steel beams exposed to fire
    Al-azzani, Hisham
    Wang, Weiyong
    Zhang, Yanhong
    Ding, Yong
    Xu, Jinyong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 197
  • [43] Experimental study on local buckling of 960 MPa high strength steel columns under axial compression
    Shi, Gang
    Lin, Cuocuo
    Zhou, Wenjing
    Wang, Yuanqing
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2014, 35 (01): : 126 - 135
  • [44] Experimental study on seismic performance of steel reinforced concrete columns after exposure to fire
    Li, Junhua
    Chen, Jianhua
    Sun, Bin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (05): : 124 - 132
  • [45] Concrete-filled high strength steel tube stub columns after exposure to fire: Testing, numerical modelling and design
    Zhong, Yukai
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2022, 177
  • [46] Experimental investigation of the overall buckling behaviour of 960 MPa high strength steel columns
    Ban, Huiyong
    Shi, Gang
    Shi, Yongjiu
    Bradford, Mark A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 88 : 256 - 266
  • [47] Experimental and numerical study on behaviour of square steel tube confined reinforced concrete stub columns after fire exposure
    Liu, Faqi
    Yang, Hua
    Yan, Rui
    Wang, Wei
    THIN-WALLED STRUCTURES, 2019, 139 : 105 - 125
  • [48] Behaviors of UHPC-filled Q960 high strength steel tubes under low- temperature compression
    Yan, Jia-Bao
    Hu, Shunnia
    Luo, Yan-Li
    Lin, Xuchua
    Zhang, Lingxin
    STEEL AND COMPOSITE STRUCTURES, 2022, 43 (02): : 201 - 219
  • [49] RESIDUAL STRESS STUDY ON WELDED SECTION OF HIGH STRENGTH Q460 STEEL AFTER FIRE EXPOSURE
    Wang, W. Y.
    Li, G. Q.
    Ge, Y.
    ADVANCED STEEL CONSTRUCTION, 2015, 11 (02): : 150 - 164
  • [50] Experimental study on seismic behavior of steel reinforced high strength concrete columns
    Zhu, Weiqing
    Jia, Jinqing
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (04): : 57 - 67