Aspects of Occlusal Recordings Performed with the T-Scan System and with the Medit Intraoral Scanner

被引:2
|
作者
Popa, Angelica Diana [1 ]
Vladutu, Diana Elena [1 ]
Turcu, Adina Andreea [2 ]
Tartea, Daniel Adrian [3 ]
Ionescu, Mihaela [4 ]
Paunescu, Catalin [5 ]
Stan, Razvan Sabin [5 ]
Mercut, Veronica [1 ]
机构
[1] Univ Med & Pharm Craiova, Dept Prosthet Dent, Craiova 200349, Romania
[2] Univ Med & Pharm Craiova, Dept Orodent Prevent, Craiova 200349, Romania
[3] Univ Med & Pharm Craiova, Dept Oral Rehabil, Craiova 200349, Romania
[4] Univ Med & Pharm Craiova, Dept Med Informat & Biostat, Craiova 200349, Romania
[5] Univ Med & Pharm Craiova, Dept IT, Craiova 200349, Romania
关键词
occlusal analysis; T-Scan III system; Medit I600 intraoral scanner; CONTACT POINTS; MAJOR PART; IN-VIVO; ACCURACY; PRECISION; DENTISTRY; FORCES; ARCH;
D O I
10.3390/diagnostics14131457
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Dental occlusion refers to the static and dynamic relationships that are established between the teeth of the two arches and is an important factor in the homeostasis of the dento-maxillary system. The objective of the present study was to compare two digital occlusal analysis systems: the T-Scan III system and the Medit I600 intraoral scanner. Materials and Methods: The study was carried out on 20 students from the Faculty of Dental Medicine Craiova, whose dental occlusion was assessed with the T-Scan III system and with the Medit I600 intraoral scanner. Dental occlusion was assessed in the maximum intercuspation position, the edge-to-edge protrusion position, and the edge-to-edge position in right and left laterotrusion. The images of the 2D occlusal contact areas obtained by both methods were converted to .jpeg format and then transferred to Adobe Photoshop CS6 2021 (Adobe Systems, San Jose, CA, USA) for comparison. The recorded data were statistically processed. Results: Analyzing the data provided by the two digital occlusal analysis systems, it was found that the T-Scan III system provided data related to the amplitude of the occlusal forces, the surface on which they were distributed (the contact surface), the dynamics of the occlusal contacts, and the proportion in which they were distributed at the level of the two hemiarches, and the Medit I600 intraoral scanner performed an evaluation of the occlusal interface of the two arches, highlighting the extent of the contact areas with the degree of overlapping of the occlusal components. Although both methods of occlusal analysis recorded the highest values for the maximum intercuspation position, the results could not be compared. Conclusions: The two digital systems provide different data in occlusal analysis. As the T-Scan III system is considered the gold standard for occlusal analysis, more studies are needed to understand the data provided by the Medit I600 intraoral scanner and their significance.
引用
收藏
页数:19
相关论文
共 50 条
  • [11] Reliability and Validity of T-scan and 3D Intraoral Scanning for Measuring the Occlusal Contact Area
    Ayuso-Montero, Raul
    Mariano-Hernandez, Yumaysla
    Khoury-Ribas, Laura
    Rovira-Lastra, Bernat
    Willaert, Eva
    Martinez-Gomis, Jordi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (01): : 19 - 25
  • [12] In vivo evaluation of T-Scan in quantifying occlusal contact
    Wang, Qing
    Zhao, Zhe
    Li, Jiale
    Zhao, Ruifeng
    Zhou, Ming
    Tang, Kai
    Bai, Shizhu
    Ma, Chufan
    Wang, Fu
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (09) : 1675 - 1683
  • [13] Customized procedure to display T-Scan occlusal contacts
    Solaberrieta, Eneko
    Etxaniz, Olatz
    Ramon Otegi, Jose
    Brizuela, Aritza
    Pradies, Guillermo
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (01): : 18 - 21
  • [14] Evaluation of the accuracy of T-scan system and Cerec Omnicam system used in occlusal contact assessment
    Cao, Rongkai
    Xu, Hui
    Lin, Jing
    Liu, Weicai
    HELIYON, 2023, 9 (02)
  • [15] Reference values and reliability of occlusal force distribution and occlusal time measured by the T-Scan system in adults with healthy dentition
    Rubio-Ferrer, Gemma
    Rovira-Lastra, Bernat
    Khoury-Ribas, Laura
    Flores-Orozco, Elan Ignacio
    Ayuso-Montero, Raul
    Martinez-Gomis, Jordi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (06): : 558 - 564
  • [16] Evaluation of occlusal pattern in periodontitis patients using T-scan analysis
    Deepika, B. A.
    Ramamurthy, Jaiganesh
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S265 - S271
  • [17] THE EFFECT OF HEAD POSTURE ON MUSCLE CONTACT POSITION USING THE T-SCAN SYSTEM OF OCCLUSAL ANALYSIS
    MAKOFSKY, HW
    SEXTON, TR
    DIAMOND, DZ
    SEXTON, MT
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 1991, 9 (04): : 316 - 321
  • [18] Effect of mandibular complete dentures relining on occlusal force distribution using T-scan system
    Eman M. Ibraheem
    Hisham S. ElGabry
    Bulletin of the National Research Centre, 45 (1)
  • [19] Study of occlusal contact variability within individuals in a position of maximum intercuspation using the T-SCAN system
    Sequeros, OG
    Garcia, VCG
    Cartagena, AG
    JOURNAL OF ORAL REHABILITATION, 1997, 24 (04) : 287 - 290
  • [20] Using the T-scan III System to Analyze Occlusal Function in Mandibular Reconstruction Patients: A Pilot Study
    Liu, Chao-Wei
    Chang, Yang-Ming
    Shen, Yu-Fu
    Hong, Hsiang-Hsi
    BIOMEDICAL JOURNAL, 2015, 38 (01) : 52 - 57