Aspects of Occlusal Recordings Performed with the T-Scan System and with the Medit Intraoral Scanner

被引:2
|
作者
Popa, Angelica Diana [1 ]
Vladutu, Diana Elena [1 ]
Turcu, Adina Andreea [2 ]
Tartea, Daniel Adrian [3 ]
Ionescu, Mihaela [4 ]
Paunescu, Catalin [5 ]
Stan, Razvan Sabin [5 ]
Mercut, Veronica [1 ]
机构
[1] Univ Med & Pharm Craiova, Dept Prosthet Dent, Craiova 200349, Romania
[2] Univ Med & Pharm Craiova, Dept Orodent Prevent, Craiova 200349, Romania
[3] Univ Med & Pharm Craiova, Dept Oral Rehabil, Craiova 200349, Romania
[4] Univ Med & Pharm Craiova, Dept Med Informat & Biostat, Craiova 200349, Romania
[5] Univ Med & Pharm Craiova, Dept IT, Craiova 200349, Romania
关键词
occlusal analysis; T-Scan III system; Medit I600 intraoral scanner; CONTACT POINTS; MAJOR PART; IN-VIVO; ACCURACY; PRECISION; DENTISTRY; FORCES; ARCH;
D O I
10.3390/diagnostics14131457
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Dental occlusion refers to the static and dynamic relationships that are established between the teeth of the two arches and is an important factor in the homeostasis of the dento-maxillary system. The objective of the present study was to compare two digital occlusal analysis systems: the T-Scan III system and the Medit I600 intraoral scanner. Materials and Methods: The study was carried out on 20 students from the Faculty of Dental Medicine Craiova, whose dental occlusion was assessed with the T-Scan III system and with the Medit I600 intraoral scanner. Dental occlusion was assessed in the maximum intercuspation position, the edge-to-edge protrusion position, and the edge-to-edge position in right and left laterotrusion. The images of the 2D occlusal contact areas obtained by both methods were converted to .jpeg format and then transferred to Adobe Photoshop CS6 2021 (Adobe Systems, San Jose, CA, USA) for comparison. The recorded data were statistically processed. Results: Analyzing the data provided by the two digital occlusal analysis systems, it was found that the T-Scan III system provided data related to the amplitude of the occlusal forces, the surface on which they were distributed (the contact surface), the dynamics of the occlusal contacts, and the proportion in which they were distributed at the level of the two hemiarches, and the Medit I600 intraoral scanner performed an evaluation of the occlusal interface of the two arches, highlighting the extent of the contact areas with the degree of overlapping of the occlusal components. Although both methods of occlusal analysis recorded the highest values for the maximum intercuspation position, the results could not be compared. Conclusions: The two digital systems provide different data in occlusal analysis. As the T-Scan III system is considered the gold standard for occlusal analysis, more studies are needed to understand the data provided by the Medit I600 intraoral scanner and their significance.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] T-Scan Novus System in the Management of Splints-Pilot Study
    Bozhkova, Tanya
    Shopova, Dobromira
    EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (02) : 454 - 457
  • [42] Assessment of occlusion with the T-Scan system in patients undergoing orthognathic surgery
    Jimoh Olubanwo Agbaje
    Elke Van de Casteele
    Ahmed S. Salem
    Dickson Anumendem
    Eman Shaheen
    Yi Sun
    Constantinus Politis
    Scientific Reports, 7
  • [43] Assessment of occlusion with the T-Scan system in patients undergoing orthognathic surgery
    Agbaje, Jimoh Olubanwo
    Van de Casteele, Elke
    Salem, Ahmed S.
    Anumendem, Dickson
    Shaheen, Eman
    Sun, Yi
    Politis, Constantinus
    SCIENTIFIC REPORTS, 2017, 7
  • [44] Application in the analysis of the occlusal force of free-end missing tooth implant restoration with T-SCAN III
    Wu, Ming-Le
    Lai, Peng-Yu
    Cheong, Fan
    Zhou, Wen-Cheng
    Xu, Sang-Hui
    Li, Hui
    Shen, Shan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [45] =T-Scan Guided Occlusal Equilibration as an Effective Treatment in the Management of Symptomatic Temporomandibular Disorders: An Open Clinical Trial
    Ignatius, Ancy, V
    Garlapati, Komali
    Chaitanya, Nallan C. S. K.
    Saba, Asra
    Kandi, Pallavi
    Reddy, Chelluri Shreya
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (01) : 53 - 59
  • [46] Association between Occlusal Forces and Periodontal Conditions in Untreated Chronic Periodontitis Using T-Scan: A Retrospective Study
    Soundarajan, Subasree
    Gajendran, Priyalochana
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (01):
  • [47] Effectiveness of T-Scan Technology in Identifying Occlusal Interferences and its Role in the Management of Temporomandibular Disorders: A Systematic Review
    Uchale, Pooja
    Deogade, Suryakant
    Khalikar, Arun
    Wankhade, Sattyam
    Taneja, Sukrit
    Lalsare, Samiksha
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (06) : ZC9 - ZC15
  • [48] Computerized dynamic occlusal analysis and its correlation with static characters in post-orthodontic patients using the T-Scan system and the ABO objective grading system
    Menglin Wang
    Le Liu
    Xihua Ma
    Xiang Jin
    Zhenbao Zhang
    Xiangmin Jia
    Jiadong Fan
    Haoning Tang
    Yanfeng Li
    BMC Oral Health, 23
  • [49] Comparison of Postorthodontic Occlusal Force Distributions between Nonextraction and Extraction Treatment Approaches of Premolars for Orthodontic Treatment by Using T-Scan III System
    Tansalarak, Ratchawan
    Khamnuengsitthi, Nattapat
    Pipatphatsakorn, Mayurach
    EUROPEAN JOURNAL OF DENTISTRY, 2024,
  • [50] Computerized dynamic occlusal analysis and its correlation with static characters in post-orthodontic patients using the T-Scan system and the ABO objective grading system
    Wang, Menglin
    Liu, Le
    Ma, Xihua
    Jin, Xiang
    Zhang, Zhenbao
    Jia, Xiangmin
    Fan, Jiadong
    Tang, Haoning
    Li, Yanfeng
    BMC ORAL HEALTH, 2023, 23 (01)