THE EFFECT OF HEAD POSTURE ON MUSCLE CONTACT POSITION USING THE T-SCAN SYSTEM OF OCCLUSAL ANALYSIS

被引:41
|
作者
MAKOFSKY, HW
SEXTON, TR
DIAMOND, DZ
SEXTON, MT
机构
关键词
D O I
10.1080/08869634.1991.11678378
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study is to investigate the effect of sagittal plane head-neck posture on initial tooth contacts (muscle contact position) using the T-Scan system of occlusal analysis. Thirty-five subjects from 14 to 72 years old were selected. Computerized T-Scan occlusal printouts were obtained on each subject with the head-neck in 45-degrees dorsiflexion and 30-degrees ventroflexion. To quantify the location of the contacts on the upper arch, the dotted lines appearing on the printout were assigned numerical values. Low numbers represent distal contacts and the higher the number, the more mesial the contact. Wilcoxon's Rank Sum Test was used to analyze the data. Results indicated that below the age of 30 years no significant relationship was demonstrated between head posture and muscle contact position. However, over the age of 30 there was an increasingly significant relationship between sagittal plane head-neck posture and initial occlusal contacts. Based on these findings, the authors recommend that management of occlusally related problems, i.e., temporomandibular disorders include an assessment of the craniovertebral region especially in patients over the age of 30 years.
引用
收藏
页码:316 / 321
页数:6
相关论文
共 50 条
  • [1] Analysis of two methods for occlusal contact registration with the T-Scan system
    Cartagena, AG
    Sequeros, OG
    Garcia, VCG
    JOURNAL OF ORAL REHABILITATION, 1997, 24 (06) : 426 - 432
  • [2] Study of occlusal contact variability within individuals in a position of maximum intercuspation using the T-SCAN system
    Sequeros, OG
    Garcia, VCG
    Cartagena, AG
    JOURNAL OF ORAL REHABILITATION, 1997, 24 (04) : 287 - 290
  • [3] In vivo evaluation of T-Scan in quantifying occlusal contact
    Wang, Qing
    Zhao, Zhe
    Li, Jiale
    Zhao, Ruifeng
    Zhou, Ming
    Tang, Kai
    Bai, Shizhu
    Ma, Chufan
    Wang, Fu
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (09) : 1675 - 1683
  • [4] T-SCAN OCCLUSAL ANALYSIS OF REMOUNT DENTURES
    KENG, SB
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 483 - 483
  • [5] SENSITIVITY AND RELIABILITY OF THE T-SCAN FOR OCCLUSAL ANALYSIS
    HSU, ML
    GALLO, LM
    PALLA, S
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 335 - 335
  • [6] Evaluation of occlusal contacts in TMD using the T-scan system.
    Panti, F
    Ciaranella, A
    De Luca, S
    Paolo, CD
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B250 - B250
  • [7] Evaluation of occlusal contacts in maximum intercuspation using the T-Scan system
    Garcia, VCG
    Cartagena, AG
    Sequeros, OG
    JOURNAL OF ORAL REHABILITATION, 1997, 24 (12): : 899 - 903
  • [8] The occlusal imaging and analysis system by T-scan III in tinnitus patients
    Di Berardino, Federica
    Filipponi, Eliana
    Schiappadori, Massimo
    Forti, Stella
    Zanetti, Diego
    Cesarani, Antonio
    BIOMEDICAL JOURNAL, 2016, 39 (02) : 139 - 144
  • [9] Evaluation of occlusal pattern in periodontitis patients using T-scan analysis
    Deepika, B. A.
    Ramamurthy, Jaiganesh
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S265 - S271
  • [10] Evaluation of the accuracy of T-scan system and Cerec Omnicam system used in occlusal contact assessment
    Cao, Rongkai
    Xu, Hui
    Lin, Jing
    Liu, Weicai
    HELIYON, 2023, 9 (02)