Aspects of Occlusal Recordings Performed with the T-Scan System and with the Medit Intraoral Scanner

被引:2
|
作者
Popa, Angelica Diana [1 ]
Vladutu, Diana Elena [1 ]
Turcu, Adina Andreea [2 ]
Tartea, Daniel Adrian [3 ]
Ionescu, Mihaela [4 ]
Paunescu, Catalin [5 ]
Stan, Razvan Sabin [5 ]
Mercut, Veronica [1 ]
机构
[1] Univ Med & Pharm Craiova, Dept Prosthet Dent, Craiova 200349, Romania
[2] Univ Med & Pharm Craiova, Dept Orodent Prevent, Craiova 200349, Romania
[3] Univ Med & Pharm Craiova, Dept Oral Rehabil, Craiova 200349, Romania
[4] Univ Med & Pharm Craiova, Dept Med Informat & Biostat, Craiova 200349, Romania
[5] Univ Med & Pharm Craiova, Dept IT, Craiova 200349, Romania
关键词
occlusal analysis; T-Scan III system; Medit I600 intraoral scanner; CONTACT POINTS; MAJOR PART; IN-VIVO; ACCURACY; PRECISION; DENTISTRY; FORCES; ARCH;
D O I
10.3390/diagnostics14131457
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Dental occlusion refers to the static and dynamic relationships that are established between the teeth of the two arches and is an important factor in the homeostasis of the dento-maxillary system. The objective of the present study was to compare two digital occlusal analysis systems: the T-Scan III system and the Medit I600 intraoral scanner. Materials and Methods: The study was carried out on 20 students from the Faculty of Dental Medicine Craiova, whose dental occlusion was assessed with the T-Scan III system and with the Medit I600 intraoral scanner. Dental occlusion was assessed in the maximum intercuspation position, the edge-to-edge protrusion position, and the edge-to-edge position in right and left laterotrusion. The images of the 2D occlusal contact areas obtained by both methods were converted to .jpeg format and then transferred to Adobe Photoshop CS6 2021 (Adobe Systems, San Jose, CA, USA) for comparison. The recorded data were statistically processed. Results: Analyzing the data provided by the two digital occlusal analysis systems, it was found that the T-Scan III system provided data related to the amplitude of the occlusal forces, the surface on which they were distributed (the contact surface), the dynamics of the occlusal contacts, and the proportion in which they were distributed at the level of the two hemiarches, and the Medit I600 intraoral scanner performed an evaluation of the occlusal interface of the two arches, highlighting the extent of the contact areas with the degree of overlapping of the occlusal components. Although both methods of occlusal analysis recorded the highest values for the maximum intercuspation position, the results could not be compared. Conclusions: The two digital systems provide different data in occlusal analysis. As the T-Scan III system is considered the gold standard for occlusal analysis, more studies are needed to understand the data provided by the Medit I600 intraoral scanner and their significance.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Digital Occlusion Analysis after Orthodontic Treatment: Capabilities of the Intraoral Scanner and T-Scan Novus System
    Shopova, Dobromira
    Bakova, Desislava
    Yordanova, Svetlana
    Yordanova, Miroslava
    Uzunov, Todor
    APPLIED SCIENCES-BASEL, 2023, 13 (07):
  • [2] T-Scan: Streamlining Occlusal Verification
    Venugopalan, Suresh
    Maiti, Subhabrata
    Nallaswamy, Deepak
    Nesappan, Thiyaneswaran
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2023, 35 (04) : 614 - 616
  • [3] The reproducibility of occlusal contacts by T-scan
    Wang, JC
    Hong, JM
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 2359 - 2359
  • [4] Digital Occlusal Analyser T-Scan: A Review
    Gade, Jaykumar R.
    Agrawal, Megha J.
    Dandekar, Sayali G.
    Soni, Minal N.
    Jaiswal, Karan, V
    Ingole, Anil
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (11): : 187 - 193
  • [5] T-SCAN OCCLUSAL ANALYSIS OF REMOUNT DENTURES
    KENG, SB
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 483 - 483
  • [6] SENSITIVITY AND RELIABILITY OF THE T-SCAN FOR OCCLUSAL ANALYSIS
    HSU, ML
    GALLO, LM
    PALLA, S
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 335 - 335
  • [7] Evaluation of occlusal contacts in TMD using the T-scan system.
    Panti, F
    Ciaranella, A
    De Luca, S
    Paolo, CD
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B250 - B250
  • [8] Analysis of two methods for occlusal contact registration with the T-Scan system
    Cartagena, AG
    Sequeros, OG
    Garcia, VCG
    JOURNAL OF ORAL REHABILITATION, 1997, 24 (06) : 426 - 432
  • [9] Evaluation of occlusal contacts in maximum intercuspation using the T-Scan system
    Garcia, VCG
    Cartagena, AG
    Sequeros, OG
    JOURNAL OF ORAL REHABILITATION, 1997, 24 (12): : 899 - 903
  • [10] The occlusal imaging and analysis system by T-scan III in tinnitus patients
    Di Berardino, Federica
    Filipponi, Eliana
    Schiappadori, Massimo
    Forti, Stella
    Zanetti, Diego
    Cesarani, Antonio
    BIOMEDICAL JOURNAL, 2016, 39 (02) : 139 - 144