Digital Occlusion Analysis after Orthodontic Treatment: Capabilities of the Intraoral Scanner and T-Scan Novus System

被引:4
|
作者
Shopova, Dobromira [1 ]
Bakova, Desislava [2 ]
Yordanova, Svetlana [3 ]
Yordanova, Miroslava [3 ]
Uzunov, Todor [4 ]
机构
[1] Med Univ Plovdiv, Fac Dent Med, Dept Prosthet Dent, Plovdiv 4000, Bulgaria
[2] Med Univ Plovdiv, Fac Publ Hlth, Dept Healthcare Management, Plovdiv 4000, Bulgaria
[3] Med Univ Plovdiv, Fac Dent Med, Dept Orthodont, Plovdiv 4000, Bulgaria
[4] Med Univ Sofia, Fac Dent Med, Dept Prosthet Dent, Sofia 1431, Bulgaria
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 07期
关键词
dentistry; digital impression; digital occlusion; intraoral scanning; 3Shape; T-Scan Novus; orthodontics; FUNCTIONAL OCCLUSION; RETENTION; ACCURACY; PARAMETERS; IMPRESSION; FORCE;
D O I
10.3390/app13074335
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Digital technology is becoming increasingly popular in dentistry. The aim of this article is to demonstrate and compare the capabilities of two different digital approaches, namely, intraoral scanning and digital examination of occlusion, in the final analysis of occlusion after orthodontic treatment. The capabilities and limitations of both systems are emphasized to help clinicians determine which system to use in specific cases. Materials and methods: The study included 32 patients (15 males and 17 females) in the retention phase after orthodontic treatment. Patients were aged 15 to 28 years with a mean age of 18.62 years (+/- 4.17), and 62.2% were aged under 18 years. At the beginning of the orthodontic treatment, 18 patients had Angle Class I and 14 had Angle Class II. Overall, 18 patients were treated without extractions and 14 with extractions, while 12 had impacted teeth. All patients wore an Essix retainer in the upper jaw and a fixed canine-to-canine retainer in the lower jaw. Intraoral scanning was performed using Trios color (3Shape, Copenhagen, Denmark, 2014), and digital occlusion imaging was performed using T-Scan Novus (Tekscan, Norwood, MA, USA, 2018). SPSS 23.0 was used to perform descriptive statistical analysis. Result and Conclusion: With the 3Shape system, the contacts are marked based on the proximity between dentitions. The T-Scan system measures the strength of the contacts, regardless of their area. Despite its many advantages, intraoral scanning is not a reliable method for recording occlusions. The results obtained are not incorrect, but they include limited parameters for analysis. The T-Scan system provides comprehensive results and allows analysis and treatment of occlusal dysfunctions. The T-Scan system can provide information on the first contact, strength of the contacts, contact distribution on each tooth, sequence of contacts, maximum bite force and maximum intercuspation, path of the lower jaw movement, and occlusion and disocclusion times as well as record videos with active sequences and distributions of the contacts. There is a good collaboration between intraoral scanning and digital occlusion determination.
引用
收藏
页数:13
相关论文
共 35 条
  • [1] T-Scan Novus System Application-Digital Occlusion Analysis of 3D Printed Orthodontics Retainers
    Shopova, Dobromira
    Yaneva, Antoniya
    Bakova, Desislava
    Mihaylova, Anna
    Yordanova, Miroslava
    Yordanova, Svetlana
    APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [2] Aspects of Occlusal Recordings Performed with the T-Scan System and with the Medit Intraoral Scanner
    Popa, Angelica Diana
    Vladutu, Diana Elena
    Turcu, Adina Andreea
    Tartea, Daniel Adrian
    Ionescu, Mihaela
    Paunescu, Catalin
    Stan, Razvan Sabin
    Mercut, Veronica
    DIAGNOSTICS, 2024, 14 (13)
  • [3] The Occlusion Time Evaluation of in Iraqi Patients with TMJ Internal Derangement Utilizing T-Scan (NOVUS) System
    Kadhem, Zena Kamel
    Aswad, Fawaz
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2020, 8 (06): : 77 - 82
  • [4] T-Scan Novus System in the Management of Splints-Pilot Study
    Bozhkova, Tanya
    Shopova, Dobromira
    EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (02) : 454 - 457
  • [5] Evaluation of occlusion parameters using T-scan III in patients receiving fixed orthodontic treatment
    Sadry, Sanaz
    Giray, Bilgin
    APOS TRENDS IN ORTHODONTICS, 2023, 13 (02) : 91 - 99
  • [6] Comparison of Occlusal Digital Analysis Using T-Scan in Orthognathic Surgery with Only Conventional Orthodontic Patients
    Manikandhan, R.
    Manikandan, S.
    Ponvel, Keerthana
    Parameswaran, Ratna
    Shankar, Sathya
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2023, 22 (02): : 397 - 409
  • [7] Comparison of Occlusal Digital Analysis Using T-Scan in Orthognathic Surgery with Only Conventional Orthodontic Patients
    R. Manikandhan
    S. Manikandan
    Keerthana Ponvel
    Ratna Parameswaran
    Sathya Shankar
    Journal of Maxillofacial and Oral Surgery, 2023, 22 : 397 - 409
  • [8] OCCLUSION AND ARTICULATION IN BRUXISM AND BRUXOMANIA INVESTIGATED WITH THE SYSTEM T-SCAN III
    Dimova, Mariana
    JOURNAL OF IMAB, 2014, 20 (05): : 655 - 660
  • [9] Assessment of occlusion with the T-Scan system in patients undergoing orthognathic surgery
    Jimoh Olubanwo Agbaje
    Elke Van de Casteele
    Ahmed S. Salem
    Dickson Anumendem
    Eman Shaheen
    Yi Sun
    Constantinus Politis
    Scientific Reports, 7
  • [10] Assessment of occlusion with the T-Scan system in patients undergoing orthognathic surgery
    Agbaje, Jimoh Olubanwo
    Van de Casteele, Elke
    Salem, Ahmed S.
    Anumendem, Dickson
    Shaheen, Eman
    Sun, Yi
    Politis, Constantinus
    SCIENTIFIC REPORTS, 2017, 7