Prompt gamma timing for proton range verification with TlBr and TlCl as pure Cherenkov emitters

被引:3
|
作者
Ellin, Justin [1 ]
Rebolo, Leonor [1 ]
Backfish, Michael [2 ]
Prebys, Eric [2 ,3 ]
Arino-Estrada, Gerard [1 ,4 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, Crocker Nucl Lab, Davis, CA USA
[3] Univ Calif Davis, Dept Phys, Davis, CA USA
[4] Barcelona Inst Sci & Technol, Inst Fis Altes Energies, Barcelona, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 11期
关键词
prompt gamma timing; TlBr; TlCl; Proton therapy range verification;
D O I
10.1088/1361-6560/ad4304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Prompt gamma timing (PGT) uses the detection time of prompt gammas emitted along the range of protons in proton radiotherapy to verify the position of the Bragg peak (BP). Cherenkov detectors offer the possibility of enhanced signal-to-noise ratio (SNR) due to the inherent physics of Cherenkov emission which enhances detection of high energy prompt gamma rays relative to other induced uncorrelated signals. In this work, the PGT technique was applied to 3 semiconductor material slabs that emit only Cherenkov light for use in a full scale system: a 3 x 3 x 20 mm3 TlBr, a 12 x 12 x 12 mm3 TlBr, and a 5 x 5 x 5 mm3 TlCl. Approach. A polymethyl methacrylate (PMMA) target was exposed to a 67.5 MeV, 0.5 nA proton beam and shifted in 3 mm increments at the Crocker nuclear laboratory (CNL) in Davis, CA, USA. A fast plastic scintillator coupled to a photomultiplier tube (PMT) provided the start reference for the proton time of flight. Time of flight (TOF) distributions were generated using this reference and the gamma-ray timestamp in the Cherenkov detector. Main results. The SNR of the proton correlated peaks relative to the background was 20, 29, and 30 for each of the three samples, respectively. The upper limit of the position resolutions with the TlCl sample were 2 mm, 3 mm, and 5 mm for 30k, 10k, and 5k detected events, respectively. The time distribution of events with respect to the reference reproduced with clarity the periodicity of the beam, implying a very high SNR of the Cherenkov crystals to detect prompt gammas. Background presence from the neutron-induced continuum, prompt gammas from deuterium, or positron activation were not observed. Material choice and crystal dimensions did not seem to affect significantly the outcome of the results. Significance. These results show the high SNR of the pure Cherenkov emitters TlBr and TlCl for the detection of prompt gammas in a proton beam with current of clinical significance and their potential for verifying the proton range. The accuracy in determining shifts of the BP was highly dependent on the number of events acquired, therefore, the performance of these detectors are expected to vary with different beam conditions such as current, pulse repetition, and proton bunch width.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Processing of prompt gamma-ray timing data for proton range measurements at a clinical beam delivery
    Werner, Theresa
    Berthold, Jonathan
    Hueso-Gonzalez, Fernando
    Koegler, Toni
    Petzoldt, Johannes
    Roemer, Katja
    Richter, Christian
    Rinscheid, Andreas
    Straessner, Arno
    Enghardt, Wolfgang
    Pausch, Guntram
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (10):
  • [42] Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    Lee, Se Byeong
    MEDICAL PHYSICS, 2012, 39 (04) : 2100 - 2107
  • [43] A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning
    Jiang, Zhuoran
    Polf, Jerimy C.
    Barajas, Carlos A.
    Gobbert, Matthias K.
    Ren, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (07):
  • [44] Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification
    Nenoff, Lena
    Priegnitz, Marlen
    Janssens, Guillaume
    Petzoldt, Johannes
    Wohlfahrt, Patrick
    Trezza, Anna
    Smeets, Julien
    Pausch, Guntram
    Richter, Christian
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) : 534 - 540
  • [45] Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1063 - 1082
  • [46] Energy- and time-resolved detection of prompt gamma-rays for proton range verification
    Verburg, Joost M.
    Riley, Kent
    Bortfeld, Thomas
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20): : L37 - L49
  • [47] In-Vivo Range Verification and Tissue Response to Proton Radiotherapy Using Prompt Gamma Volume Histograms
    Polf, J.
    Lin, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3199 - 3199
  • [48] Compton Camera and Prompt Gamma Ray Timing: Two Methods for In Vivo Range Assessment in Proton Therapy
    Hueso-Gonzalez, Fernando
    Fiedler, Fine
    Golnik, Christian
    Kormoll, Thomas
    Pausch, Guntram
    Petzoldt, Johannes
    Roemer, Katja E.
    Enghardt, Wolfgang
    FRONTIERS IN ONCOLOGY, 2016, 6
  • [49] Development of a Clinical Prototype for Range Verification in Proton Therapy based on Prompt Gamma-Ray Spectroscopy
    Hueso-Gonzalez, F.
    Rabe, M.
    Ruggieri, T. A.
    Bortfeld, T.
    Verburg, J. M.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [50] Optimization of Collimator Designs for Real-Time Proton Range Verification by Measuring Prompt Gamma Rays
    Cambraia Lopes, P.
    Pinto, M.
    Simoes, H.
    Biegun, A. K.
    Dendooven, P.
    Oxley, D. C.
    Parodi, K.
    Schaart, D. R.
    Crespo, P.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3864 - 3870