Objective. Prompt gamma timing (PGT) uses the detection time of prompt gammas emitted along the range of protons in proton radiotherapy to verify the position of the Bragg peak (BP). Cherenkov detectors offer the possibility of enhanced signal-to-noise ratio (SNR) due to the inherent physics of Cherenkov emission which enhances detection of high energy prompt gamma rays relative to other induced uncorrelated signals. In this work, the PGT technique was applied to 3 semiconductor material slabs that emit only Cherenkov light for use in a full scale system: a 3 x 3 x 20 mm3 TlBr, a 12 x 12 x 12 mm3 TlBr, and a 5 x 5 x 5 mm3 TlCl. Approach. A polymethyl methacrylate (PMMA) target was exposed to a 67.5 MeV, 0.5 nA proton beam and shifted in 3 mm increments at the Crocker nuclear laboratory (CNL) in Davis, CA, USA. A fast plastic scintillator coupled to a photomultiplier tube (PMT) provided the start reference for the proton time of flight. Time of flight (TOF) distributions were generated using this reference and the gamma-ray timestamp in the Cherenkov detector. Main results. The SNR of the proton correlated peaks relative to the background was 20, 29, and 30 for each of the three samples, respectively. The upper limit of the position resolutions with the TlCl sample were 2 mm, 3 mm, and 5 mm for 30k, 10k, and 5k detected events, respectively. The time distribution of events with respect to the reference reproduced with clarity the periodicity of the beam, implying a very high SNR of the Cherenkov crystals to detect prompt gammas. Background presence from the neutron-induced continuum, prompt gammas from deuterium, or positron activation were not observed. Material choice and crystal dimensions did not seem to affect significantly the outcome of the results. Significance. These results show the high SNR of the pure Cherenkov emitters TlBr and TlCl for the detection of prompt gammas in a proton beam with current of clinical significance and their potential for verifying the proton range. The accuracy in determining shifts of the BP was highly dependent on the number of events acquired, therefore, the performance of these detectors are expected to vary with different beam conditions such as current, pulse repetition, and proton bunch width.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Experimental Study of Discrete Prompt Gamma Lines for In-Vivo Proton Range Verification
    Verburg, J.
    Riley, K.
    Seco, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [22] Range verification of passively scattered proton beams based on prompt gamma time patterns
    Testa, Mauro
    Min, Chul Hee
    Verburg, Joost M.
    Schuemann, Jan
    Lu, Hsiao-Ming
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (15): : 4181 - 4195
  • [23] A Fast Analytical Approach for Prompt Gamma and PET Predictions in a TPS for Proton Range Verification
    Kroniger, K.
    Herzog, M.
    Landry, G.
    Traneus, E.
    Dedes, G.
    Parodi, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3199 - 3199
  • [24] Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy
    Xie, Yunhe
    Bentefour, El Hassane
    Janssens, Guillaume
    Smeets, Julien
    Vander Stappen, Francois
    Hotoiu, Lucian
    Yin, Lingshu
    Dolney, Derek
    Avery, Stephen
    O'Grady, Fionnbarr
    Prieels, Damien
    McDonough, James
    Solberg, Timothy D.
    Lustig, Robert A.
    Lin, Alexander
    Teo, Boon-Keng K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (01): : 210 - 218
  • [25] First clinical application of a prompt gamma based in vivo proton range verification system
    Richter, Christian
    Pausch, Guntram
    Barczyk, Steffen
    Priegnitz, Marlen
    Keitz, Isabell
    Thiele, Julia
    Smeets, Julien
    Stappen, Francois Vander
    Bombelli, Luca
    Fiorini, Carlo
    Hotoiu, Lucian
    Perali, Irene
    Prieels, Damien
    Enghardt, Wolfgang
    Baumann, Michael
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 (02) : 232 - 237
  • [26] Clinical Translation of Prompt Gamma-Ray Spectroscopy for In Vivo Proton Range Verification
    Verburg, J.
    Ruggieri, T.
    Botas, P.
    Cascio, E.
    Hueso-Gonzalez, F.
    Rabe, M.
    BortfeId, T.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [27] Can Prompt Gamma Emission During Proton Therapy Provide in Situ Range Verification?
    Styczynski, J.
    Riley, K.
    Binns, P.
    Bortfeld, T.
    Paganetti, H.
    MEDICAL PHYSICS, 2009, 36 (06) : 2425 - +
  • [28] A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
    Maxime Jacquet
    Saba Ansari
    Marie-Laure Gallin-Martel
    Adélie André
    Yannick Boursier
    Mathieu Dupont
    Jilali Es-smimih
    Laurent Gallin-Martel
    Joël Hérault
    Christophe Hoarau
    Johan-Petter Hofverberg
    Daniel Maneval
    Christian Morel
    Jean-François Muraz
    Fabrice Salicis
    Sara Marcatili
    Scientific Reports, 13
  • [29] A high sensitivity Cherenkov detector for prompt gamma timing and time imaging
    Jacquet, Maxime
    Ansari, Saba
    Gallin-Martel, Marie-Laure
    Andre, Adelie
    Boursier, Yannick
    Dupont, Mathieu
    Es-smimih, Jilali
    Gallin-Martel, Laurent
    Herault, Joel
    Hoarau, Christophe
    Hofverberg, Johan-Petter
    Maneval, Daniel
    Morel, Christian
    Muraz, Jean-Francois
    Salicis, Fabrice
    Marcatili, Sara
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [30] A Method to Improve the Spatial Resolution of Prompt Gamma Based Compton Imaging for Proton Range Verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Beddar, S.
    Polf, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3451 - 3451