Prompt gamma timing for proton range verification with TlBr and TlCl as pure Cherenkov emitters

被引:3
|
作者
Ellin, Justin [1 ]
Rebolo, Leonor [1 ]
Backfish, Michael [2 ]
Prebys, Eric [2 ,3 ]
Arino-Estrada, Gerard [1 ,4 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, Crocker Nucl Lab, Davis, CA USA
[3] Univ Calif Davis, Dept Phys, Davis, CA USA
[4] Barcelona Inst Sci & Technol, Inst Fis Altes Energies, Barcelona, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 11期
关键词
prompt gamma timing; TlBr; TlCl; Proton therapy range verification;
D O I
10.1088/1361-6560/ad4304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Prompt gamma timing (PGT) uses the detection time of prompt gammas emitted along the range of protons in proton radiotherapy to verify the position of the Bragg peak (BP). Cherenkov detectors offer the possibility of enhanced signal-to-noise ratio (SNR) due to the inherent physics of Cherenkov emission which enhances detection of high energy prompt gamma rays relative to other induced uncorrelated signals. In this work, the PGT technique was applied to 3 semiconductor material slabs that emit only Cherenkov light for use in a full scale system: a 3 x 3 x 20 mm3 TlBr, a 12 x 12 x 12 mm3 TlBr, and a 5 x 5 x 5 mm3 TlCl. Approach. A polymethyl methacrylate (PMMA) target was exposed to a 67.5 MeV, 0.5 nA proton beam and shifted in 3 mm increments at the Crocker nuclear laboratory (CNL) in Davis, CA, USA. A fast plastic scintillator coupled to a photomultiplier tube (PMT) provided the start reference for the proton time of flight. Time of flight (TOF) distributions were generated using this reference and the gamma-ray timestamp in the Cherenkov detector. Main results. The SNR of the proton correlated peaks relative to the background was 20, 29, and 30 for each of the three samples, respectively. The upper limit of the position resolutions with the TlCl sample were 2 mm, 3 mm, and 5 mm for 30k, 10k, and 5k detected events, respectively. The time distribution of events with respect to the reference reproduced with clarity the periodicity of the beam, implying a very high SNR of the Cherenkov crystals to detect prompt gammas. Background presence from the neutron-induced continuum, prompt gammas from deuterium, or positron activation were not observed. Material choice and crystal dimensions did not seem to affect significantly the outcome of the results. Significance. These results show the high SNR of the pure Cherenkov emitters TlBr and TlCl for the detection of prompt gammas in a proton beam with current of clinical significance and their potential for verifying the proton range. The accuracy in determining shifts of the BP was highly dependent on the number of events acquired, therefore, the performance of these detectors are expected to vary with different beam conditions such as current, pulse repetition, and proton bunch width.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Analytical computation of prompt gamma ray emission and detection for proton range verification
    Sterpin, E.
    Janssens, G.
    Smeets, J.
    Stappen, Francois Vander
    Prieels, D.
    Priegnitz, Marlen
    Perali, Irene
    Vynckier, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12): : 4915 - 4946
  • [12] Proton Beam Range Verification with a Single Prompt Gamma-Ray Detector
    Verburg, J.
    Testa, M.
    Cascio, E.
    Bortfeld, T.
    Lu, H.
    Seco, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 495 - 495
  • [13] A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy
    Draeger, E.
    Chen, H.
    Mackin, D.
    Peterson, S.
    Avery, S.
    Beddar, S.
    Polf, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3757 - 3757
  • [14] 3D prompt gamma imaging for proton beam range verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Avery, S.
    Beddar, S.
    Polf, J. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [15] Spectroscopic study of prompt-gamma emission for range verification in proton therapy
    Kelleter, Laurent
    Wronska, Aleksandra
    Besuglow, Judith
    Konefal, Adam
    Laihem, Karim
    Leidner, Johannes
    Magiera, Andrzej
    Parodi, Katia
    Rusiecka, Katarzyna
    Stahl, Achim
    Tessonnier, Thomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 7 - 17
  • [16] Proton Range Verification of Scanned Pencil Beams Using Prompt Gamma Imaging
    Xie, Y.
    Bentefour, E.
    Janssens, G.
    Smeets, J.
    Dolney, D.
    Yin, L.
    Hotoiu, L.
    Vander Stappen, F.
    Avery, S.
    O'Grady, F.
    Prieels, D.
    McDonough, J.
    Solberg, T.
    Lin, A.
    Teo, B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3717 - 3717
  • [17] Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams
    Verburg, J.
    Bortfeld, T.
    Seco, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3548 - 3548
  • [18] Analytical Computation of Prompt Gamma Ray Emission and Detection for Proton Range Verification
    Sterpin, E.
    Janssens, G.
    Smeets, J.
    Prieels, D.
    Vynckier, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 550 - 550
  • [19] Translation of a prompt gamma based proton range verification system to first clinical application
    Richter, C.
    Pausch, G.
    Barczyk, S.
    Priegnitz, M.
    Golnik, C.
    Bombelli, L.
    Enghardt, W.
    Fiedler, F.
    Fiorini, C.
    Hotoiu, L.
    Janssens, G.
    Keitz, I.
    Mein, S.
    Perali, I.
    Prieels, D.
    Smeets, J.
    Thiele, J.
    Vander Stappen, F.
    Werner, T.
    Baumann, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S214 - S214
  • [20] Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning
    Tian, Liheng
    Huang, Ze
    Janssens, Guillaume
    Landry, Guillaume
    Dedes, George
    Kamp, Florian
    Belka, Claus
    Pinto, Marco
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):