Development and optimization of a backscatter X-ray detection system based on pencil beam scanning

被引:0
|
作者
Park, Jaehyun [1 ]
An, Geunyoung [2 ]
Song, Gyohyeok [1 ]
Kim, Wonku [1 ]
Kim, Junhyeok [1 ]
Lim, Kyung Taek [3 ]
Hwang, Jisung [1 ]
Cho, Gyuseong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, 291 Daehak Ro, Daejeon 34141, South Korea
[2] Jeonbuk Natl Univ, Dept Appl Plasma & Quantum Beam Engn, 567 Baekje Do, Jeonju, South Korea
[3] Sejong Univ, Dept Quantum & Nucl Engn, Seoul 05006, South Korea
基金
新加坡国家研究基金会;
关键词
Backscatter X-ray; Backscatter X-ray image; PVT; Compton scattering; DAQ board; DETECTION EFFICIENCY;
D O I
10.1016/j.nima.2024.169277
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The backscatter X-ray system makes an image by detecting scattered particles from an object in the opposite direction by Compton scattering. This system has the advantage of detecting drugs or explosives composed of organic substances. In this study, we developed a backscatter X-ray detection system. The 6-ch DAQ system is able to store acquired data for 50 mu s as 8 bytes and the 6-ch high voltage power supply board provides adjustable power from 0 to 1600 V. Using this detection system, we varied the tube voltage from 80 to 160 kV and observed backscatter X-ray images of two plastic phantoms at 160 kV. The results indicate a need to optimize the speed of the collimator and data acquisition time of the DAQ system to improve image quality. The backscatter X-ray imaging technology exhibits high scalability, making it applicable not only to security screening but also for medical and industrial purposes.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Pilot study with a scanning-beam digital X-ray system.
    Wolff, MR
    Keevil, JG
    Speidel, MA
    Wilfley, M
    Star-Lack, JM
    Heanue, JA
    Van Lysel, MS
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 95E - 96E
  • [42] Registration of pencil beam proton radiography data with X-ray CT
    Deffet, Sylvain
    Macq, Benoit
    Righetto, Roberto
    Stappen, Francois Vander
    Farace, Paolo
    MEDICAL PHYSICS, 2017, 44 (10) : 5393 - 5401
  • [43] X-ray backscatter imaging
    Dinca, Dan-Cristian
    Schubert, Jeffrey R.
    Callerame, J.
    OPTICS AND PHOTONICS IN GLOBAL HOMELAND SECURITY IV, 2008, 6945
  • [44] X-RAY BACKSCATTER IMAGING
    TOWE, BC
    JACOBS, AM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (09) : 646 - 654
  • [45] Development of online cable eccentricity detection system based on X-ray CCD
    Chen, Jian-Zhen
    Li, Bin
    Wei, Kai-Xia
    Guo, Lan-Ying
    Qu, Guo-Pu
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (02): : 230 - 233
  • [46] Estimation and Detection Information Tradeoff for X-ray System Optimization
    Cushing, Johnathan B.
    Clarkson, Eric W.
    Mandava, Sagar
    Bilgin, Ali
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX), 2016, 9847
  • [47] OPTIMIZATION OF A SYNCHROTRON BASED X-RAY LITHOGRAPHIC SYSTEM
    BERNIERI, E
    BALERNA, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2137 - 2139
  • [48] Cross calibration of fan beam and pencil beam dual energy X-ray absorptiometers
    Evans, WD
    Martin, JC
    Rajan, KT
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : S71 - S72
  • [49] Detection of explosive devices using X-ray backscatter radiation
    Faust, AA
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS IV, 2002, 4786 : 17 - 28
  • [50] X-RAY PRINTS BY SCANNING-BEAM EXPOSURE
    WEBSTER, AC
    INDUSTRIAL PHOTOGRAPHY, 1969, 18 (09): : 42 - &