Development and optimization of a backscatter X-ray detection system based on pencil beam scanning

被引:0
|
作者
Park, Jaehyun [1 ]
An, Geunyoung [2 ]
Song, Gyohyeok [1 ]
Kim, Wonku [1 ]
Kim, Junhyeok [1 ]
Lim, Kyung Taek [3 ]
Hwang, Jisung [1 ]
Cho, Gyuseong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, 291 Daehak Ro, Daejeon 34141, South Korea
[2] Jeonbuk Natl Univ, Dept Appl Plasma & Quantum Beam Engn, 567 Baekje Do, Jeonju, South Korea
[3] Sejong Univ, Dept Quantum & Nucl Engn, Seoul 05006, South Korea
基金
新加坡国家研究基金会;
关键词
Backscatter X-ray; Backscatter X-ray image; PVT; Compton scattering; DAQ board; DETECTION EFFICIENCY;
D O I
10.1016/j.nima.2024.169277
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The backscatter X-ray system makes an image by detecting scattered particles from an object in the opposite direction by Compton scattering. This system has the advantage of detecting drugs or explosives composed of organic substances. In this study, we developed a backscatter X-ray detection system. The 6-ch DAQ system is able to store acquired data for 50 mu s as 8 bytes and the 6-ch high voltage power supply board provides adjustable power from 0 to 1600 V. Using this detection system, we varied the tube voltage from 80 to 160 kV and observed backscatter X-ray images of two plastic phantoms at 160 kV. The results indicate a need to optimize the speed of the collimator and data acquisition time of the DAQ system to improve image quality. The backscatter X-ray imaging technology exhibits high scalability, making it applicable not only to security screening but also for medical and industrial purposes.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Development and field testing of a mobile backscatter X-ray lateral migration radiography land mine detection system
    Dugan, ET
    Jacobs, AM
    Zhong, S
    Houssay, L
    Ekdahl, D
    Brygoo, S
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS VII, PTS 1 AND 2, 2002, 4742 : 120 - 131
  • [32] Optimization of ripple filter for pencil beam scanning
    YANG Zhaoxia
    ZHANG Manzhou
    LI Deming
    NuclearScienceandTechniques, 2013, 24 (06) : 97 - 101
  • [33] Optimization of ripple filter for pencil beam scanning
    Yang Zhaoxia
    Zhang Manzhou
    Li Deming
    NUCLEAR SCIENCE AND TECHNIQUES, 2013, 24 (06)
  • [34] Ground-based X-ray Calibration of the Astro-E2 X-ray Telescope I. with Pencil Beam
    Itoh, Akiharu
    Haba, Yoshito
    Hayakawa, Akira
    Iizuka, Ryo
    Inoue, Chiaki
    Inoue, Hirohiko
    Ishida, Manabu
    Itoh, Kei
    Kunieda, Hideyo
    Maeda, Yoshitomo
    Misaki, Kazutami
    Mori, Hideyuki
    Naitou, Masataka
    Okada, Shunsaku
    Shibata, Ryo
    Shimizu, Tomoo
    Yokoyama, Yuushi
    Proc SPIE Int Soc Opt Eng, 1600, PART 1 (93-102):
  • [35] Development and assessment of an x-ray tube-based multi-beam x-ray scatter projection imaging system
    Dydula, Christopher
    Johns, Paul C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (11):
  • [36] Ground-based X-ray calibration of the Astro-E2 X-ray telescope - I. With pencil beam
    Itoh, A
    Haba, Y
    Hayakawa, A
    Iizuka, R
    Inoue, C
    Inoue, H
    Ishida, M
    Itoh, K
    Kunieda, H
    Maeda, Y
    Misaki, K
    Mori, H
    Naitou, M
    Okada, S
    Shibata, R
    Shimizu, T
    Yokoyama, Y
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 93 - 102
  • [37] Performance assessment of the scanning-beam digital x-ray (SBDX) system
    VanLysel, MS
    Solomon, EG
    Wilfley, BP
    Dutta, A
    Speidel, MA
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 161 - 170
  • [38] Scanning-beam digital x-ray (SBDX) system for cardiac angiography
    Solomon, EG
    Wilfley, BP
    Van Lysel, MS
    Joseph, AW
    Heanue, JA
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 246 - 257
  • [39] IMPROVED ELECTRON BEAM SCANNING SYSTEM FOR ELECTRON MICROPROBE X-RAY ANALYZERS
    KNISELEY, RN
    LAABS, FC
    VANZUUK, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (12): : 1804 - &
  • [40] Low-exposure scanning-beam x-ray fluoroscopy system
    Solomon, EG
    VanLysel, MS
    Melen, RE
    Moorman, JW
    Skillicorn, B
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 140 - 149