Calibrated intraoral scan protocol (CISP) for full-arch implant impressions: An in vitro comparison to conventional impression, intraoral scan, and intraoral scan with scan-aid

被引:2
|
作者
Li, Junying [1 ]
Chen, Zhaozhao [2 ]
Nava, Paolo [2 ]
Yang, Shengtao [1 ,3 ]
Calatrava, Javier [2 ,4 ]
Wang, Hom-Lay [2 ]
机构
[1] Univ Michigan, Sch Dent, Dept Biol & Mat Sci, Div Prosthodont, 1011 North Univ Ave, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI USA
[3] Sichuan Univ, West China Hosp Stomatol, Natl Ctr Stomatol,Dept Dent Technol, Natl Clin Res Ctr Oral Dis,State Key Lab Oral Dis, Chengdu, Peoples R China
[4] Univ Complutense, Fac Odontol, Sect Grad Periodontol, Madrid, Spain
关键词
accuracy; dental implant; dental impression; full-arch; intraoral scanner; ACCURACY; PROSTHESES; FIT;
D O I
10.1111/cid.13338
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To assess a newly developed intraoral scan protocol in enhancing the accuracy of complete-arch implant impressions. Materials and Methods Four impression approaches were applied to the same maxillary edentulous model with 6 implants: (1) intraoral scan (IOS), (2) intraoral scan with scan aid (IOS-SA), (3) calibrated intraoral scan protocol (CISP), and (4) conventional splinted open-tray impression (CONV). Each approach was repeated 10 times, and a direct scan of the model with a desktop scanner was used as a reference model. The alignment of scans and the reference model was conducted by two methods: (a) aligning all scan bodies to evaluate the overall fit, and (b) aligning the first and second scan bodies to simulate the Sheffield fit test for passive fitting of multiple implant-supported prostheses. Linear deviations from the reference model (trueness) and within each group (precision) were analyzed using Python scripts. Results When aligned by all scan bodies, the CISP group exhibited comparable mean trueness (38.33 mu m) and precision (45.97 mu m) to the CONV group (44.30 and 47.92 mu m respectively), both of which significantly outperformed the IOS group (86.82 and 83.17 mu m, respectively). Furthermore, in the virtual Sheffield fit test, the CISP group achieved the highest levels of mean trueness at the end span (121.7 mu m), making a linear deviation reduction of 36.7%, 60%, and 41.4% when compared to the CONV, the IOS, and the IOS-SA groups, respectively. Moreover, the CISP group (104.3 mu m) displayed a remarkable 65, 182, and 86 mu m advantage in precision over the CONV, IOS, and IOS-SA groups, respectively. Conclusion CISP demonstrated comparable accuracy to the gold standard, the conventional splinted open-tray impression. Furthermore, it excelled in the virtual passive fitting test.
引用
收藏
页码:879 / 888
页数:10
相关论文
共 50 条
  • [41] Three-dimensional positional accuracy of intraoral and laboratory implant scan bodies
    Tan, Janice Zhi Hui
    Tan, Ming Yi
    Toh, Yoong Liang See
    Wong, Kuan Yee
    Tan, Keson Beng Choon
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 735 - 744
  • [42] Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner
    Mueller, Philipp
    Ender, Andreas
    Joda, Tim
    Katsoulis, Joannis
    QUINTESSENCE INTERNATIONAL, 2016, 47 (04): : 343 - 349
  • [43] Continuous Scan Strategy (CSS): A Novel Technique to Improve the Accuracy of Intraoral Digital Impressions
    Imburgia, Mario
    Kois, John
    Marino, Elio
    Lerner, Henriette
    Mangano, Francesco G.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2020, 28 (03): : 128 - 141
  • [44] Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: An in vitro study
    Jamjoom, Faris Z.
    Aldghim, Adhwaa
    Aldibasi, Omar
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1218 - 1225
  • [45] In vitro evaluation of the impact of intraoral scanner, scanning aids, and the scanned arch on the scan accuracy of edentulous arches
    Jamjoom, Faris Z.
    Aldghim, Adhwaa
    Aldibasi, Omar
    Yilmaz, Burak
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [46] Effect of preparation design and scan pattern on the accuracy of intraoral scans for complete arch laminate veneers under simulated intraoral variables
    Sen, Nazmiye
    Eroglu, Hatice
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (10) : 1437 - 1443
  • [47] Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study
    Gomez-Polo, Miguel
    Alvarez, Francisco
    Ortega, Rocio
    Gomez-Polo, Cristina
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    JOURNAL OF DENTISTRY, 2022, 121
  • [48] Maxillomandibular relationship and virtual facebow integration in complete-arch intraoral implant scan: A novel clinical technique
    Nuytens, Philippe
    Grande, Francesco
    Li, Junying
    Lepidi, Luca
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [49] Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners
    Azevedo, Luis
    Marques, Tiago
    Karasan, Duygu
    Fehmer, Vincent
    Sailer, Irena
    Correia, Andre
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 204 - 210
  • [50] Accuracy of intraoral scanning using modified scan bodies for complete arch implant-supported fixed prostheses
    Li, Yanxi
    Fang, He
    Yan, Yuwei
    Geng, Wei
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 994e1 - 994e8