Calibrated intraoral scan protocol (CISP) for full-arch implant impressions: An in vitro comparison to conventional impression, intraoral scan, and intraoral scan with scan-aid

被引:2
|
作者
Li, Junying [1 ]
Chen, Zhaozhao [2 ]
Nava, Paolo [2 ]
Yang, Shengtao [1 ,3 ]
Calatrava, Javier [2 ,4 ]
Wang, Hom-Lay [2 ]
机构
[1] Univ Michigan, Sch Dent, Dept Biol & Mat Sci, Div Prosthodont, 1011 North Univ Ave, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI USA
[3] Sichuan Univ, West China Hosp Stomatol, Natl Ctr Stomatol,Dept Dent Technol, Natl Clin Res Ctr Oral Dis,State Key Lab Oral Dis, Chengdu, Peoples R China
[4] Univ Complutense, Fac Odontol, Sect Grad Periodontol, Madrid, Spain
关键词
accuracy; dental implant; dental impression; full-arch; intraoral scanner; ACCURACY; PROSTHESES; FIT;
D O I
10.1111/cid.13338
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To assess a newly developed intraoral scan protocol in enhancing the accuracy of complete-arch implant impressions. Materials and Methods Four impression approaches were applied to the same maxillary edentulous model with 6 implants: (1) intraoral scan (IOS), (2) intraoral scan with scan aid (IOS-SA), (3) calibrated intraoral scan protocol (CISP), and (4) conventional splinted open-tray impression (CONV). Each approach was repeated 10 times, and a direct scan of the model with a desktop scanner was used as a reference model. The alignment of scans and the reference model was conducted by two methods: (a) aligning all scan bodies to evaluate the overall fit, and (b) aligning the first and second scan bodies to simulate the Sheffield fit test for passive fitting of multiple implant-supported prostheses. Linear deviations from the reference model (trueness) and within each group (precision) were analyzed using Python scripts. Results When aligned by all scan bodies, the CISP group exhibited comparable mean trueness (38.33 mu m) and precision (45.97 mu m) to the CONV group (44.30 and 47.92 mu m respectively), both of which significantly outperformed the IOS group (86.82 and 83.17 mu m, respectively). Furthermore, in the virtual Sheffield fit test, the CISP group achieved the highest levels of mean trueness at the end span (121.7 mu m), making a linear deviation reduction of 36.7%, 60%, and 41.4% when compared to the CONV, the IOS, and the IOS-SA groups, respectively. Moreover, the CISP group (104.3 mu m) displayed a remarkable 65, 182, and 86 mu m advantage in precision over the CONV, IOS, and IOS-SA groups, respectively. Conclusion CISP demonstrated comparable accuracy to the gold standard, the conventional splinted open-tray impression. Furthermore, it excelled in the virtual passive fitting test.
引用
收藏
页码:879 / 888
页数:10
相关论文
共 50 条
  • [31] Comparison of Intraoral Scanning Modes in Three Distinct Full-Arch Digital Implant Impression Scenarios: An In Vitro Study
    Sezer, Taygun
    Yilmaz, Erkan
    Esim, Emir
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : e217 - e222
  • [32] THE ACCURACY OF INTRAORAL SCAN IN OBTAINING DIGITAL IMPRESSIONS OF EDENTULOUS ARCHES: A SYSTEMATIC REVIEW
    Wang, Yiyang
    Li, Yaning
    Liang, Shanshan
    Yuan, Fusong
    Liu, Yunsong
    Ye, Hongqiang
    Zhou, Yongsheng
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2024, 24 (01)
  • [33] Patients' preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (Intraoral Scan) of dental implants
    Wismeijer, Daniel
    Mans, Ronny
    van Genuchten, Michiel
    Reijers, Hajo A.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (10) : 1113 - 1118
  • [34] Accuracy of the digital implant impression with splinted and non-splinted intraoral scan bodies: A systematic review
    Shetty, Pratiksha Shankar
    Gangurde, Arti P.
    Chauhan, Manish R.
    Jaiswal, Niraja V.
    Salian, Pradnya R.
    Singh, Vikram
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01): : 3 - 12
  • [35] Evaluating the impact of scan body angulation and geometric attachments on the accuracy of complete-arch digital implant impressions: A comparison of two intraoral scanners
    Farah, Ra'fat I.
    Alresheedi, Bandar
    Alazmi, Saad
    Al-Haj Ali, Sanaa N.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (02): : 174 - 181
  • [36] Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scans
    Gomez-Polo, Miguel
    Sallorenzo, Alessandro
    Ortega, Rocio
    Gomez-Polo, Cristina
    Barmak, Abdul B.
    Att, Wael
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 119 - 127
  • [37] Effect of supramucosal height of a scan body and implant angulation on the accuracy of intraoral scanning: An in vitro study
    Sicilia, Elena
    Lagreca, Gabriela
    Papaspyridakos, Panos
    Finkelman, Matthew
    Cobo, Juan
    Att, Wael
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1126 - 1134
  • [38] Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study
    Kernen, Florian
    Braendle, Dominik
    Wagendorf, Oliver
    Recca, Mario
    Mehrhof, Juergen
    Vach, Kirstin
    Nahles, Susanne
    Nelson, Katja
    Fluegge, Tabea
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (08) : 793 - 801
  • [39] Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
    Ryan Jin Young Kim
    Goran I. Benic
    Ji-Man Park
    Scientific Reports, 11
  • [40] Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
    Kim, Ryan Jin Young
    Benic, Goran, I
    Park, Ji-Man
    SCIENTIFIC REPORTS, 2021, 11 (01)