Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners

被引:11
|
作者
Azevedo, Luis [1 ,6 ]
Marques, Tiago [2 ]
Karasan, Duygu [3 ]
Fehmer, Vincent [4 ]
Sailer, Irena [3 ]
Correia, Andre [2 ]
Gomez-Polo, Miguel [5 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[2] Univ Catolica Portuguesa UCP, Fac Dent Med, Viseu, Portugal
[3] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[4] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[5] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[6] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, S-N Plaza Ramon y Cajal, Madrid 28040, Spain
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 01期
关键词
IMPRESSION TECHNIQUES; ACCURACY; PROSTHESES; PRECISION;
D O I
10.1016/j.prosdent.2023.06.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The absence of fixed reference points can affect the trueness of complete arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete arch digital implant scans is still unclear. Purpose. The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete arch digital implant scans with 5 intraoral scanners (IOSs). Material and methods. Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (alpha=.05). Results. The mean +/- standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 +/- 8 pm, 53 +/- 7 pm, and 49 +/- 11 pm, respectively, with no statistically significant differences ( P=.06). Significant differences were found for the IOSs used with each technique ( P<.001). Primescan (27 +/- 4 pm cIOSs; 28 +/- 3 pm sIOSs; 31 +/- 3 pm AL-IOSs) showed significantly higher trueness than iTero 5D (47 +/- 5 pm cIOSs; 47 +/- 4 pm sIOSs; 50 +/- 6 pm AL-IOSs) ( P=.002) and TRIOS 4 (93 +/- 18 pm cIOSs; 76 +/- 18 pm sIOSs; 107 +/- 13 pm AL-IOSs) ( P=.001) for all techniques. In addition, no significant differences were found between the techniques by using iTero 5D or Primescan ( P=.348 and P=.059, respectively). Conclusions. The cIOSs, sIOSs, and AL-IOSs techniques showed similar trueness. The IOS used influenced the trueness of complete arch digital implant scans. (J Prosthet Dent 2024;132:204-210)
引用
收藏
页码:204 / 210
页数:7
相关论文
共 50 条
  • [1] Effect of splinting scan bodies on trueness of complete-arch implant impression using different intraoral scanners: an in vitro study
    Retana, Luciano
    Nejat, Amir H.
    Pozzi, Alessandro
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2023, 26 (01) : 19 - 28
  • [2] Evaluating the effects of splinting implant scan bodies intraorally on the trueness of complete arch digital scans: A clinical study
    Ali, Kawther
    Alzaid, Abdulaziz A.
    Suprono, Montry S.
    Garbacea, Antoanela
    Savignano, Roberto
    Kattadiyil, Mathew T.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04): : 781e1 - 781e7
  • [3] Influence of splinting scan bodies or incorporating three- dimensionally printed scan aids on the trueness of complete arch digital scans
    Eddin, Motasem Bellah Bader
    Onoral, Ozay
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04): : 828e1 - 828e12
  • [4] Effect of implant scan body geometric modi fi cations on the trueness and scanning time of complete arch intraoral implant digital scans: An in vitro study
    Lawand, Ghida
    Ismail, Yara
    Revilla-Leon, Marta
    Tohme, Hani
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1189 - 1197
  • [5] Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
    Ryan Jin Young Kim
    Goran I. Benic
    Ji-Man Park
    Scientific Reports, 11
  • [6] Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
    Kim, Ryan Jin Young
    Benic, Goran, I
    Park, Ji-Man
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [7] Effect of Scan Pattern on the Accuracy of Complete-Arch Digital Implant Impressions with Two Intraoral Scanners
    Li, Zhipeng
    Huang, Ruoxuan
    Wu, Xiayi
    Chen, Zetao
    Huang, Baoxin
    Chen, Zhuofan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 731 - 739
  • [8] TRUENESS EVALUATION OF LATEST GENERATION OF INTRAORAL SCANNERS ON COMPLETE-ARCH IMPLANT IMPRESSIONS
    Issever, Dilara Seyma Alpkilic
    Deger, Sabire isler
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (04) : e1 - e12
  • [9] Effect of different surface locking patterns on the trueness of complete arch digital implant scans: An in vitro study
    Kondakji, Elissa
    Lawand, Ghida
    Yaacoub, Wassim
    Tohme, Hani
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03): : 601e1 - 601e9
  • [10] Improving the accuracy of complete arch implant digital scans by using auxiliary clips for intraoral scan bodies: A dental technique
    Etxaniz, Olatz
    Amezua, Xabier
    Jauregi, Mikel
    Solaberrieta, Eneko
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (01): : 43 - 47