Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners

被引:11
|
作者
Azevedo, Luis [1 ,6 ]
Marques, Tiago [2 ]
Karasan, Duygu [3 ]
Fehmer, Vincent [4 ]
Sailer, Irena [3 ]
Correia, Andre [2 ]
Gomez-Polo, Miguel [5 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[2] Univ Catolica Portuguesa UCP, Fac Dent Med, Viseu, Portugal
[3] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[4] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[5] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[6] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, S-N Plaza Ramon y Cajal, Madrid 28040, Spain
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 01期
关键词
IMPRESSION TECHNIQUES; ACCURACY; PROSTHESES; PRECISION;
D O I
10.1016/j.prosdent.2023.06.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The absence of fixed reference points can affect the trueness of complete arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete arch digital implant scans is still unclear. Purpose. The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete arch digital implant scans with 5 intraoral scanners (IOSs). Material and methods. Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (alpha=.05). Results. The mean +/- standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 +/- 8 pm, 53 +/- 7 pm, and 49 +/- 11 pm, respectively, with no statistically significant differences ( P=.06). Significant differences were found for the IOSs used with each technique ( P<.001). Primescan (27 +/- 4 pm cIOSs; 28 +/- 3 pm sIOSs; 31 +/- 3 pm AL-IOSs) showed significantly higher trueness than iTero 5D (47 +/- 5 pm cIOSs; 47 +/- 4 pm sIOSs; 50 +/- 6 pm AL-IOSs) ( P=.002) and TRIOS 4 (93 +/- 18 pm cIOSs; 76 +/- 18 pm sIOSs; 107 +/- 13 pm AL-IOSs) ( P=.001) for all techniques. In addition, no significant differences were found between the techniques by using iTero 5D or Primescan ( P=.348 and P=.059, respectively). Conclusions. The cIOSs, sIOSs, and AL-IOSs techniques showed similar trueness. The IOS used influenced the trueness of complete arch digital implant scans. (J Prosthet Dent 2024;132:204-210)
引用
收藏
页码:204 / 210
页数:7
相关论文
共 50 条
  • [21] Comparison of different artificial landmarks and scanning patterns on the complete-arch implant intraoral digital scans
    Kanjanasavitree, Primprapa
    Thammajaruk, Putsadeeporn
    Guazzato, Massimiliano
    JOURNAL OF DENTISTRY, 2022, 125
  • [22] Effect of coded healing abutment height and position on the trueness of digital intraoral implant scans
    Batak, Burcu
    Yilmaz, Burak
    Shah, Karnik
    Rathi, Rajat
    Schimmel, Martin
    Lang, Lisa
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (03): : 466 - 472
  • [23] Influence of Implant ScanBody Material and Intraoral Scanners on the Accuracy of Complete-Arch Digital Implant Impressions
    Azevedo, Luis
    Marques, Tiago
    Karasan, Duygu
    Fehmer, Vincent
    Sailer, Irena
    Correia, Andre
    Polo, Miguel Gomez
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (05)
  • [24] Calibrated splinting framework for complete arch intraoral implant digital scans manufactured by combining milled and additively manufacturing technologies: A dental technique
    Llansana, Ferran
    Guirao, Sergi
    Kois, John C.
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04): : 680 - 686
  • [25] In vitro comparison of trueness of 10 intraoral scanners for implant-supported complete-arch fixed dental prostheses
    Bilmenoglu, Caglar
    Cilingir, Altug
    Geckili, Onur
    Bilhan, Hakan
    Bilgin, Tayfun
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 755 - 760
  • [26] Techniques to improve the accuracy of complete arch implant intraoral digital scans: A systematic review
    Paratelli, Andrea
    Vania, Stefano
    Gomez-Polo, Cristina
    Ortega, Rocio
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06): : 844 - 854
  • [27] Trueness of IntraoralScanners in Different Scan Patterns for Full-Arch Digital Implant Impressions
    Sezer, Taygun
    Esim, Emir
    Yilmaz, Erkan
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (04) : 426 - 430
  • [28] Effect of different intraoral scanners and post-space depths on the trueness of digital impressions
    Emam, Marwa
    Ghanem, Lomaya
    Sadek, Hoda M. Abdel
    DENTAL AND MEDICAL PROBLEMS, 2024, 61 (04) : 577 - 584
  • [29] Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study
    Meneghetti, Priscila Ceolin
    Li, Junying
    Borella, Paulo Sergio
    Mendonca, Gustavo
    Burnett Jr, Luiz Henrique
    PLOS ONE, 2023, 18 (12):
  • [30] Influence of the color of 3D-printed scan aids on the trueness of complete arch digital scans
    Onoral, Ozay
    Cakir, Selin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,