Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners

被引:11
|
作者
Azevedo, Luis [1 ,6 ]
Marques, Tiago [2 ]
Karasan, Duygu [3 ]
Fehmer, Vincent [4 ]
Sailer, Irena [3 ]
Correia, Andre [2 ]
Gomez-Polo, Miguel [5 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[2] Univ Catolica Portuguesa UCP, Fac Dent Med, Viseu, Portugal
[3] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[4] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[5] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[6] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, S-N Plaza Ramon y Cajal, Madrid 28040, Spain
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 01期
关键词
IMPRESSION TECHNIQUES; ACCURACY; PROSTHESES; PRECISION;
D O I
10.1016/j.prosdent.2023.06.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The absence of fixed reference points can affect the trueness of complete arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete arch digital implant scans is still unclear. Purpose. The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete arch digital implant scans with 5 intraoral scanners (IOSs). Material and methods. Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (alpha=.05). Results. The mean +/- standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 +/- 8 pm, 53 +/- 7 pm, and 49 +/- 11 pm, respectively, with no statistically significant differences ( P=.06). Significant differences were found for the IOSs used with each technique ( P<.001). Primescan (27 +/- 4 pm cIOSs; 28 +/- 3 pm sIOSs; 31 +/- 3 pm AL-IOSs) showed significantly higher trueness than iTero 5D (47 +/- 5 pm cIOSs; 47 +/- 4 pm sIOSs; 50 +/- 6 pm AL-IOSs) ( P=.002) and TRIOS 4 (93 +/- 18 pm cIOSs; 76 +/- 18 pm sIOSs; 107 +/- 13 pm AL-IOSs) ( P=.001) for all techniques. In addition, no significant differences were found between the techniques by using iTero 5D or Primescan ( P=.348 and P=.059, respectively). Conclusions. The cIOSs, sIOSs, and AL-IOSs techniques showed similar trueness. The IOS used influenced the trueness of complete arch digital implant scans. (J Prosthet Dent 2024;132:204-210)
引用
收藏
页码:204 / 210
页数:7
相关论文
共 50 条
  • [41] An additively manufactured intraoral scan body for aiding complete-arch intraoral implant digital scans with guided integration of 3D virtual representation
    Gabriel Perez-Giugovaz, Marcelo
    Mosier, Meredith
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 38 - 43
  • [42] Evaluating the impact of scan body angulation and geometric attachments on the accuracy of complete-arch digital implant impressions: A comparison of two intraoral scanners
    Farah, Ra'fat I.
    Alresheedi, Bandar
    Alazmi, Saad
    Al-Haj Ali, Sanaa N.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (02): : 174 - 181
  • [43] Influence of ambient light conditions on the accuracy and scanning time of seven intraoral scanners in complete-arch implant scans
    Ochoa-Lopez, Gaston
    Cascos, Rocio
    Antonaya-Martin, Jose Luis
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    JOURNAL OF DENTISTRY, 2022, 121
  • [44] Comparison of the accuracy of intraoral scans between complete-arch scan and quadrant scan
    Moon, Youn-Gyeong
    Lee, Kyung-Min
    PROGRESS IN ORTHODONTICS, 2020, 21 (01)
  • [45] Comparison of the accuracy of intraoral scans between complete-arch scan and quadrant scan
    Youn-Gyeong Moon
    Kyung-Min Lee
    Progress in Orthodontics, 21
  • [46] Effect of scan powder and scanning technology on measured deviations of complete-arch implant supported frameworks digitized with industrial and intraoral scanners
    Donmez, Mustafa Borga
    Cakmak, Gulce
    Dede, Dogu Omur
    Kucukekenci, Ahmet Serkan
    Lu, Wei-En
    Schumacher, Fernanda Lang
    Revilla-Leon, Marta
    Yilmaz, Burak
    JOURNAL OF DENTISTRY, 2023, 138
  • [47] Effect of scan path on accuracy of complete arch intraoral scan
    Choi, Eui-Jun
    Ko, Kyung-Ho
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (06): : 319 - 327
  • [48] Effect of substrate adjacent to the scan region on the trueness of four intraoral scanners: An in vitro study
    Elter, Bahar
    Tak, Onjen
    JOURNAL OF DENTISTRY, 2023, 138
  • [49] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 96 - 104
  • [50] Trueness and precision of mandibular complete-arch implant scans when different data acquisition methods are used
    Demirel, Munir
    Donmez, Mustafa Borga
    Sahmali, Sevil Meral
    JOURNAL OF DENTISTRY, 2023, 138