Innovating Flexor Tendon Repair Training with a Three-dimensional Printed Model

被引:0
|
作者
Boyajian, Michael K. [1 ]
Davidson, Amelia L. [1 ]
Molair, Will [1 ]
Woo, Albert S. [2 ]
Crozier, Joseph W. [2 ]
Johnson, James E. [3 ]
Bhatt, Reena [2 ]
Danelson, Kerry A. [4 ]
Argenta, Anne [1 ]
机构
[1] Atrium Hlth Wake Forest Baptist, Dept Plast & Reconstruct Surg, Winston Salem, NC USA
[2] Brown Univ, Dept Plast & Reconstruct Surg, Providence, RI USA
[3] Atrium Hlth Wake Forest Baptist, Dept Gen Surg, Winston Salem, NC USA
[4] Atrium Hlth Wake Forest Baptist, Dept Orthoped Surg, Winston Salem, NC USA
关键词
SURGERY;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Flexor tendon repair is a technically demanding procedure, with functional outcome directly proportional to skillful execution. A repair must be strong to manage early mobilization and precise to allow for gliding through the tendon sheath. As a result, junior residents face a steep learning curve that may be mitigated by exposure to surgical simulators. Methods: To facilitate flexor tendon repair training, a surgical training device and accompanying instructional video were developed. Simulation workshops were held for junior orthopedic and plastic surgery residents (n = 11). To objectively assess validity of the curriculum, study participants performed cadaveric flexor tendon repairs before and after the workshop. Anonymous recordings of these repairs were graded by two certified hand surgeons. Additionally, a tensometer was used to measure strength of repair. Results: Model realism, educational utility, and overall usefulness rated high: 4.6 +/- 0.52 95% confidence interval (CI) for realism, 4.9 +/- 0.42 95% CI for device, 4.7 +/- 0.96 95% CI for video, and 4.9 +/- 0.66 95% CI overall. Subjective confidence increased after the training session (73% ranked "moderately" or "extremely"). Likewise, scores given by the surgeons grading the repairs improved for overall quality and time of repair (pre: 2.77 +/- 0.61, post: 4.22 +/- 0.56, P= 0.0002). Strength of repair did not change (P = 0.87). Conclusions: The proposed three-dimensional surgical simulator for flexor tendon repair is realistic and useful, with improved surgical technique and improved confidence demonstrated after use. This design can be three-dimensionally printed en masse and provide value to hand surgery training curriculum.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Three-dimensional printed dry lab training models to simulate roboticassisted pancreaticojejunostomy
    Wei, Fangqiang
    Xu, Mingen
    Lai, Xuecong
    Zhang, Jiye
    Yiengpruksawan, Anusak
    Lu, Yi
    Liu, Junwei
    Wang, Zhifei
    ANZ JOURNAL OF SURGERY, 2019, 89 (12) : 1631 - 1635
  • [42] Evaluation of a Three-Dimensional Printed Interventional Simulator for Cardiac Ablation Therapy Training
    Saija, Carlo
    Sabu, Sachin
    Leung, Lisa
    Lowe, Ellie
    Al-Bahrani, Noor
    Pinto, Marco Antonio Coutinho
    Herridge, Mark
    Chowdhury, Nadia M.
    Gibson, Gregory
    Byrne, Calum
    Gabbeta, Adharvan
    Marion, Ewen
    Chavan, Rashi
    Behar, Jonathan
    Pontiki, Antonia Agapi
    Berthet-Rayne, Pierre
    Housden, Richard James
    Rhode, Kawal
    APPLIED SCIENCES-BASEL, 2024, 14 (18):
  • [43] A cost effective training tool for flexor tendon repair: Pig's trotters
    Pabari, Amit
    Lim, P.
    Linford, A.
    Gilbert, P. M.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2006, 59 (11): : 1248 - 1248
  • [44] Creation and validation of three-dimensional printed models for basic nasal endoscopic training
    Chen Zhuo
    Lyu Lei
    Zhao Yulin
    Liu Wentao
    Wu Shuangxia
    Wang Chao
    Zhang Yaqian
    Huang Shuman
    Dong Dong
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2019, 9 (06) : 695 - 701
  • [45] Three-dimensional metrology for printed electronics
    Bromberg, Vadim
    Harding, Kevin
    DIMENSIONAL OPTICAL METROLOGY AND INSPECTION FOR PRACTICAL APPLICATIONS VI, 2017, 10220
  • [46] Three-Dimensional Printed Graphene Foams
    Sha, Junwei
    Li, Yilun
    Salvatierra, Rodrigo Villegas
    Wang, Tuo
    Dong, Pei
    Ji, Yongsung
    Lee, Seoung-Ki
    Zhang, Chenhao
    Zhang, Jibo
    Smith, Robert H.
    Ajayan, Pulickel M.
    Lou, Jun
    Zhao, Naiqin
    Tour, James M.
    ACS NANO, 2017, 11 (07) : 6860 - 6867
  • [47] The effectiveness of a three-dimensional printed model for training novice healthcare professionals in central venous catheter insertion: Comment
    Daungsupawong, Hinpetch
    Wiwanitkit, Viroj
    AUSTRALIAN CRITICAL CARE, 2025, 38 (03)
  • [48] A 3-Dimensional Suture Technique for Flexor Tendon Repair: A Biomechanical Study
    Castoldi, Marie
    Solla, Federico
    Camuzard, Olivier
    Pithioux, Martine
    Rampal, Virginie
    Rosello, Olivier
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (02): : 194e1 - 194e9
  • [49] Low-cost three-dimensional printed phantom for neuraxial anesthesia training: Development and comparison to a commercial model
    Mashari, Azad
    Montealegre-Gallegos, Mario
    Jeganathan, Jelliffe
    Yeh, Lu
    Hiansen, Joshua Qua
    Meineri, Massimiliano
    Mahmood, Feroze
    Matyal, Robina
    PLOS ONE, 2018, 13 (06):
  • [50] VARIATIONS DURING AGEING IN THE THREE-DIMENSIONAL ANATOMICAL ARRANGEMENT OF FASCICLES WITHIN THE EQUINE SUPERFICIAL DIGITAL FLEXOR TENDON
    Ali, O. J.
    Comerford, E. J.
    Clegg, P. D.
    Canty-Laird, E. G.
    EUROPEAN CELLS & MATERIALS, 2018, 35 : 87 - 102