Innovating Flexor Tendon Repair Training with a Three-dimensional Printed Model

被引:0
|
作者
Boyajian, Michael K. [1 ]
Davidson, Amelia L. [1 ]
Molair, Will [1 ]
Woo, Albert S. [2 ]
Crozier, Joseph W. [2 ]
Johnson, James E. [3 ]
Bhatt, Reena [2 ]
Danelson, Kerry A. [4 ]
Argenta, Anne [1 ]
机构
[1] Atrium Hlth Wake Forest Baptist, Dept Plast & Reconstruct Surg, Winston Salem, NC USA
[2] Brown Univ, Dept Plast & Reconstruct Surg, Providence, RI USA
[3] Atrium Hlth Wake Forest Baptist, Dept Gen Surg, Winston Salem, NC USA
[4] Atrium Hlth Wake Forest Baptist, Dept Orthoped Surg, Winston Salem, NC USA
关键词
SURGERY;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Flexor tendon repair is a technically demanding procedure, with functional outcome directly proportional to skillful execution. A repair must be strong to manage early mobilization and precise to allow for gliding through the tendon sheath. As a result, junior residents face a steep learning curve that may be mitigated by exposure to surgical simulators. Methods: To facilitate flexor tendon repair training, a surgical training device and accompanying instructional video were developed. Simulation workshops were held for junior orthopedic and plastic surgery residents (n = 11). To objectively assess validity of the curriculum, study participants performed cadaveric flexor tendon repairs before and after the workshop. Anonymous recordings of these repairs were graded by two certified hand surgeons. Additionally, a tensometer was used to measure strength of repair. Results: Model realism, educational utility, and overall usefulness rated high: 4.6 +/- 0.52 95% confidence interval (CI) for realism, 4.9 +/- 0.42 95% CI for device, 4.7 +/- 0.96 95% CI for video, and 4.9 +/- 0.66 95% CI overall. Subjective confidence increased after the training session (73% ranked "moderately" or "extremely"). Likewise, scores given by the surgeons grading the repairs improved for overall quality and time of repair (pre: 2.77 +/- 0.61, post: 4.22 +/- 0.56, P= 0.0002). Strength of repair did not change (P = 0.87). Conclusions: The proposed three-dimensional surgical simulator for flexor tendon repair is realistic and useful, with improved surgical technique and improved confidence demonstrated after use. This design can be three-dimensionally printed en masse and provide value to hand surgery training curriculum.
引用
收藏
页数:8
相关论文
共 50 条
  • [22] Three-dimensional printed ultrasound and photoacoustic training phantoms for vasculature access
    Nikitichev, Daniil I.
    Xia, Wenfeng
    West, Simeon J.
    Desjardins, Adrien E.
    Ourselin, Sebastien
    Vercauteren, Tom
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [23] Comment Re: 'The use of a silicone flexor tendon as a teaching model for flexor tendon repair: A clear view.'
    Zetlitz, E.
    Strandenes, E.
    Hart, A. M.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2013, 66 (07): : 1021 - 1022
  • [24] Three-dimensional training
    Peile, Ed
    EDUCATION FOR PRIMARY CARE, 2010, 21 (02) : 67 - 67
  • [25] Investigations into flexor tendon repair: a research journey over three decades
    Tang, Jin Bo
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (06) : 568 - 579
  • [26] Three-dimensional printed hydrogel model vs cadaver: comparing inflatable penile prosthesis training and evaluation
    Saba, Patrick
    Cook, Andrew
    Melnyk, Rachel
    Schuler, Nathan
    Holler, Tyler
    Witthaus, Michael
    Ralph, David
    Collins, Justin
    Bettocchi, Carlo
    Van Renterghem, Koenraad
    Ghazi, Ahmed
    JOURNAL OF SEXUAL MEDICINE, 2023, : 1126 - 1132
  • [27] FLEXOR TENDON REPAIR IN PERFECT SAFETY - A MODEL FOR STUDENT PRACTICE
    HOEYBERGHS, JL
    FLEMMING, AFS
    EUROPEAN JOURNAL OF PLASTIC SURGERY, 1994, 17 (04) : 215 - 217
  • [28] The use of amniotic membrane in flexor tendon repair: an experimental model
    Fahir Demirkan
    Nagehan Colakoglu
    Ozkan Herek
    Gürkan Erkula
    Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 396 - 399
  • [29] The use of amniotic membrane in flexor tendon repair: an experimental model
    Demirkan, F
    Colakoglu, N
    Herek, O
    Erkula, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (07) : 396 - 399
  • [30] Three-Dimensional Printed Tooth Model with Root Canal Ledge: A Novel Educational Tool for Endodontic Training
    Zhang, Rui
    Tang, Renjie
    Spintzyk, Sebastian
    Tian, Yuting
    Xiang, Yong
    Xu, Yichen
    Hu, Tao
    DENTISTRY JOURNAL, 2023, 11 (09)