Innovating Flexor Tendon Repair Training with a Three-dimensional Printed Model

被引:0
|
作者
Boyajian, Michael K. [1 ]
Davidson, Amelia L. [1 ]
Molair, Will [1 ]
Woo, Albert S. [2 ]
Crozier, Joseph W. [2 ]
Johnson, James E. [3 ]
Bhatt, Reena [2 ]
Danelson, Kerry A. [4 ]
Argenta, Anne [1 ]
机构
[1] Atrium Hlth Wake Forest Baptist, Dept Plast & Reconstruct Surg, Winston Salem, NC USA
[2] Brown Univ, Dept Plast & Reconstruct Surg, Providence, RI USA
[3] Atrium Hlth Wake Forest Baptist, Dept Gen Surg, Winston Salem, NC USA
[4] Atrium Hlth Wake Forest Baptist, Dept Orthoped Surg, Winston Salem, NC USA
关键词
SURGERY;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Flexor tendon repair is a technically demanding procedure, with functional outcome directly proportional to skillful execution. A repair must be strong to manage early mobilization and precise to allow for gliding through the tendon sheath. As a result, junior residents face a steep learning curve that may be mitigated by exposure to surgical simulators. Methods: To facilitate flexor tendon repair training, a surgical training device and accompanying instructional video were developed. Simulation workshops were held for junior orthopedic and plastic surgery residents (n = 11). To objectively assess validity of the curriculum, study participants performed cadaveric flexor tendon repairs before and after the workshop. Anonymous recordings of these repairs were graded by two certified hand surgeons. Additionally, a tensometer was used to measure strength of repair. Results: Model realism, educational utility, and overall usefulness rated high: 4.6 +/- 0.52 95% confidence interval (CI) for realism, 4.9 +/- 0.42 95% CI for device, 4.7 +/- 0.96 95% CI for video, and 4.9 +/- 0.66 95% CI overall. Subjective confidence increased after the training session (73% ranked "moderately" or "extremely"). Likewise, scores given by the surgeons grading the repairs improved for overall quality and time of repair (pre: 2.77 +/- 0.61, post: 4.22 +/- 0.56, P= 0.0002). Strength of repair did not change (P = 0.87). Conclusions: The proposed three-dimensional surgical simulator for flexor tendon repair is realistic and useful, with improved surgical technique and improved confidence demonstrated after use. This design can be three-dimensionally printed en masse and provide value to hand surgery training curriculum.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Establishment of an in vivo turkey model for the study of flexor tendon repair
    Kadar, Assaf
    Liu, Haoyu
    Vrieze, Alyssa M.
    Meier, Thomas R.
    Thoreson, Andrew R.
    Amadio, Peter C.
    Moran, Steven L.
    Zhao, Chunfeng
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (09) : 2497 - 2505
  • [32] Three-dimensional reconstruction of magnetic resonance images of a displaced flexor hallucis longus tendon in hallux valgus
    Sanders, AP
    Weijers, RE
    Snijders, CJ
    Schon, LC
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2005, 95 (04) : 401 - 404
  • [33] Novel use of a three-dimensional in vitro environment; does flexor and extensor tendon cell behavior differ?
    Stanley, Rachael Louise
    Carolin, Amy Miriam
    Agabalyan, Natasha Anahid
    Evans, Darrell John Rhys
    FASEB JOURNAL, 2013, 27
  • [34] Tendon fibroblasts in three-dimensional culture
    Fish, RS
    Ralphs, JR
    INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, 2005, 86 (03) : A35 - A36
  • [35] The utilization of three-dimensional imaging and three-dimensional-printed model in autologous microtia reconstruction
    Koento, Trimartani
    Damara, Fachreza Aryo
    Reksodiputro, Mirta Hediyati
    Safitri, Eka Dian
    Anatriera, Raden Ayu
    Widodo, Dini Widiarni
    Dewi, Dwi Juliana
    ANNALS OF MEDICINE AND SURGERY, 2024, 86 (05): : 2926 - 2934
  • [36] The Role of Three-Dimensional Printing in the Nuss Procedure: Three-Dimensional Printed Model-Assisted Nuss Procedure
    Lin, Kuan-Hsun
    Huang, Yi-Jhih
    Hsu, Hsiang-He
    Lee, Shih-Chun
    Huang, Hsu-Kai
    Chen, Ying-Yi
    Chang, Hung
    Chen, Jia-En
    Huang, Tsai-Wang
    ANNALS OF THORACIC SURGERY, 2018, 105 (02): : 413 - 417
  • [37] Superior sealing effect of a three-dimensional printed modified supraglottic airway compared with the i-gel in a three-dimensional printed airway model
    Kimijima, Tomohiko
    Edanaga, Mitsutaka
    Yamakage, Michiaki
    JOURNAL OF ANESTHESIA, 2018, 32 (05) : 655 - 662
  • [38] Superior sealing effect of a three-dimensional printed modified supraglottic airway compared with the i-gel in a three-dimensional printed airway model
    Tomohiko Kimijima
    Mitsutaka Edanaga
    Michiaki Yamakage
    Journal of Anesthesia, 2018, 32 : 655 - 662
  • [39] Stent grafting simulation using a three-dimensional printed model for extensive aortic arch repair combined with coarctation
    Shijo, Takayuki
    Shirakawa, Takashi
    Yoshitatsu, Masao
    Iwata, Keiji
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (03) : 593 - 595
  • [40] Three-Dimensional Printed Skull Base Simulation for Transnasal Endoscopic Surgical Training
    Zheng, Jia-Ping
    Li, Chu-Zhong
    Chen, Guo-Qiang
    Song, Gui-Dong
    Zhang, Ya-Zhuo
    WORLD NEUROSURGERY, 2018, 111 : E773 - E782