Automated Test for Monthly Quality Assurance of Optical Surface Imaging Dynamic Localization Accuracy

被引:0
|
作者
Young, Kaleigh [1 ]
Wright, Eric A. [2 ]
机构
[1] Univ British Columbia, Fac Med, Okanagan Campus, Kelowna, BC, Canada
[2] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Med Phys, Toronto, ON, Canada
关键词
optical imaging; radiation therapy technology; optical surface imaging; surface-guided radiotherapy; general radiation oncology;
D O I
10.7759/cureus.56242
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The American Association of Physicists in Medicine (AAPM) recently published the report of Task Group (TG) 302, which provides recommendations on acceptance, commissioning, and ongoing routine quality assurance (QA) for surface-guided radiation therapy (SGRT) systems. One of the recommended monthly QA tests is a dynamic localization accuracy test. This work aimed to develop an automated procedure for monthly SGRT dynamic localization QA. An anthropomorphic head phantom was rigidly attached to the 6-dof couch of a TrueBeam linac. TrueBeam Developer Mode was used to take an MV image of the phantom at the starting position, then automatically drive the couch through a series of translations and rotations, taking an MV image after each translation. The Identify SGRT system monitored the motion of the phantom surface from the starting position. Translations assessed on MV images were compared to translations reported in trajectory log files and Identify log files. Rotations were compared between trajectory log files and Identify log files. Three experiments were conducted. None of the translations or rotations from any experiment exceeded the tolerance values for stereotactic ablative body radiation therapy (SABR) recommended by AAPM TG-142. Maximum deviations from the expected translation values from MV imaging, trajectory log files, and Identify log files were -0.94mm, -0.11mm, and -0.78mm, respectively. Maximum deviations from the expected rotation values from trajectory log files and Identify log files were 0.01 and -0.2 degrees, respectively. The proposed method is a simple automated way to complete monthly dynamic localization QA of SGRT systems.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] OPTICAL METHOD TO TEST SURFACE QUALITY
    VERBUNT, J
    NON-DESTRUCTIVE TESTING, 1972, 5 (05): : 261 - &
  • [22] Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation
    Hirashima, Hideaki
    Miyabe, Yuki
    Nakamura, Mitsuhiro
    Mukumoto, Nobutaka
    Mizowaki, Takashi
    Hiraoka, Masahiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 234 - 242
  • [23] Automated Analysis of Leaf Position Accuracy for Multi-Leaf Collimator Quality Assurance
    Du, W.
    Casey, K.
    Kudchadker, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Integrating quality assurance in autoimmunity: the changing face of the automated ANA IIF test
    Van Hoovels, Lieve
    Bossuyt, Xavier
    Manfredi, Mariangela
    Grossi, Valentina
    Benucci, Maurizio
    Van den Bremt, Stefanie
    De Baere, Heidi
    Franceschi, Daria
    Tosi, Emiliano
    Meoni, Marco
    Bizzaro, Nicola
    Infantino, Maria
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (07) : 1247 - 1255
  • [25] Fully automated quality assurance and localization of volumetric MEG for single-subject mapping
    Stevens, Tynan
    Bardouille, Tim
    Stroink, Gerhard
    Boe, Shaun
    Patterson, Steve
    Beyea, Steven
    JOURNAL OF NEUROSCIENCE METHODS, 2016, 266 : 21 - 31
  • [26] Further development of the online analysis of dynamic test gases for quality assurance
    Kaus, C.
    Nuernberger, F.
    Rupp, J.
    Breuer, D.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2019, 79 (05): : 159 - 163
  • [27] Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators
    Johnstone, Chris
    Bazalova-Carter, Magdalena
    MEDICAL PHYSICS, 2016, 43 (08) : 4930 - 4930
  • [28] A quality assurance test phantom for the Varian PortalVision(TM) imaging system
    Jones, CH
    Mubata, CD
    Bidmead, AM
    QUANTITATIVE IMAGING IN ONCOLOGY: 19TH L H GRAY CONFERENCE, 1996, : 119 - 122
  • [29] Optimizing Monthly Quality Assurance Setup of Planar Ion Chamber Array Using Surface Guidance
    McIlrath, D. R.
    Martinez, S. K.
    DeCampos, K. R.
    Sullivan, M. P.
    Ahmad, S.
    Ritrosky, T. M.
    MEDICAL PHYSICS, 2024, 51 (10) : 7969 - 7969
  • [30] Sophisticated test objects for the quality assurance of optical computed tomography scanners
    Rahman, A. T. Abdul
    Braeuer-Krisch, Elke
    Brochard, Thierry
    Adamovics, John
    Clowes, S. K.
    Bradley, David
    Doran, Simon J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14): : 4177 - 4199