Optimizing Monthly Quality Assurance Setup of Planar Ion Chamber Array Using Surface Guidance

被引:0
|
作者
McIlrath, D. R. [1 ]
Martinez, S. K. [1 ]
DeCampos, K. R. [2 ]
Sullivan, M. P. [1 ]
Ahmad, S. [1 ]
Ritrosky, T. M. [3 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK USA
[2] Intermt Hlth, Salt Lake City, UT USA
[3] OUHSC, Oklahoma City, OK USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO- GPV-T
引用
收藏
页码:7969 / 7969
页数:1
相关论文
共 50 条
  • [1] Monthly Quality Assurance For Rotational Delivery Using An Ion Chamber Array
    Danzer, J.
    Ramsey, C.
    Neeley, M.
    Harris, C.
    Charara, Y.
    Sharp, M.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [2] VMAT Monthly Quality Assurance Using a 2D Ionization Chamber Array
    Myers, P.
    Buckey, C.
    Mihailidis, D.
    Mavroidis, P.
    Esquivel, C.
    Gutierrez, A.
    Papanikolaou, N.
    Stathakis, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Factor 10 Expedience of Monthly Linac Quality Assurance via an Ion Chamber Array and Automation Scripts
    Skinner, Lawrie B.
    Yang, Yong
    Hsu, Annie
    Xing, Lei
    Yu, Amy S.
    Niedermayr, Thomas
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [4] Leaves position accuracy and quality assurance of MLC with an ion chamber array
    Das, I
    Szeglin, S
    Bieda, M
    Cheng, C
    MEDICAL PHYSICS, 2002, 29 (06) : 1320 - 1320
  • [5] The use of an ion chamber array for routine dynamic MLC quality assurance
    Norrlinger, B
    Islam, M
    Ramaseshan, R
    Heaton, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1273 - 1273
  • [6] Streamlined Quality Assurance on Positioning Guidance Systems with Single Phantom Setup
    Du, Y.
    Zhou, S.
    Li, J.
    Yu, S.
    Yue, H.
    Wang, M.
    Wu, H.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1454 - S1455
  • [7] Volumetric Modulated Arc Therapy Treatment Quality Assurance Using An Ion Chamber Array and a Software-Modified Phantom
    Han, B.
    Phillips, T.
    Luxton, G.
    MEDICAL PHYSICS, 2012, 39 (06) : 3785 - 3786
  • [8] High resolution ion chamber array delivery quality assurance for robotic radiosurgery: Commissioning and validation
    Blanck, Oliver
    Masi, Laura
    Chan, Mark K. H.
    Adamczyk, Sebastian
    Albrecht, Christian
    Damme, Marie-Christin
    Loutfi-Krauss, Britta
    Alraun, Manfred
    Fehr, Roman
    Ramm, Ulla
    Siebert, Frank-Andre
    Stelljes, Tenzin Sonam
    Poppinga, Daniela
    Poppe, Bjoern
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (06): : 838 - 846
  • [9] Clinical Experience Implementing An Ion Chamber Array for Monthly Beam Constancy Versus Ion Chamber in Water
    Barbee, D.
    Taneja, S.
    Rea, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E718 - E719
  • [10] IMRT quality assurance using Thebes II, linear ton-chamber array
    Goddu, S
    Pereira, G
    Low, D
    Drzymala, R
    Klein, E
    MEDICAL PHYSICS, 2004, 31 (06) : 1726 - 1726