Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

被引:3
|
作者
Costa, Tatiana Dias [1 ]
da Fonseca e Silva, Elison [2 ]
Caetano, Paula Liparini [3 ]
da Silva Campos, Marcio Jose [3 ]
Resende, Leandro Marques [4 ]
Machado, Andre Guimaraes [1 ]
Resende do Carmo, Antonio Marcio [4 ]
机构
[1] Juiz de Fora Estacio Univ Ctr, Dept Endodont, Juiz De Fora, MG, Brazil
[2] Fed Inst Juiz de Fora, Dept Met Engn, Juiz De Fora, MG, Brazil
[3] Fed Inst Juiz de Fora, Dept Orthodont, Ivon Jose Cury 2, BR-36037467 Juiz De Fora, MG, Brazil
[4] Univ Fed Juiz de Fora, Dept Endodont, Juiz De Fora, MG, Brazil
来源
RESTORATIVE DENTISTRY AND ENDODONTICS | 2021年 / 46卷 / 01期
关键词
Corrosion; Endodontics; Root Canal; STAINLESS-STEEL; SODIUM-HYPOCHLORITE; ETHYLENEDIAMINETETRAACETIC ACID; TORSIONAL PROPERTIES; ROTARY INSTRUMENTS; SUSCEPTIBILITY; FATIGUE; ALLOYS;
D O I
10.5395/rde.2021.46.e6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickeltitanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (E-corr). The pitting potential (E-pit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for E-corr) and the Student t-test for independent samples (for E-pit). Results: The mean E-corr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with E-pit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Assessment of the Mechanical Properties of ProTaper Next Nickel-Titanium Rotary Files
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    JOURNAL OF ENDODONTICS, 2014, 40 (11) : 1830 - 1834
  • [42] The Impact of Multiple Autoclave Cycles on the Surface Roughness of Thermally Treated Nickel-Titanium Endodontic Files
    Ba-Hattab, Raidan
    Almohareb, Rahaf A.
    Alkhalaf, Rana
    Binnjefan, Shikhah
    Sulayem, Meral
    Barakat, Reem M.
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [43] Effect of autoclaving cycles on the surface topography of endodontic nickel-Titanium rotary files: A systematic review
    Nighot, Nikhil B.
    Borkar, Anamika C.
    Shetty, Soumya S.
    Tiwari, Nitika
    Maral, Sayali A.
    Kamath, Shruti
    JOURNAL OF THE INTERNATIONAL CLINICAL DENTAL RESEARCH ORGANIZATION, 2019, 11 (02) : 61 - 70
  • [44] Corrosion of nickel-titanium instruments
    Sonntag, David
    Heithecker, Karolin
    ENDO-ENDODONTIC PRACTICE TODAY, 2008, 2 (03): : 185 - 191
  • [45] THE FUNDAMENTAL PROPERTIES OF THE NICKEL-TITANIUM ENDODONTIC INSTRUMENTS
    KUBOTA, M
    TERATA, R
    MINAMI, K
    KUDOU, Y
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 560 - 560
  • [46] Effect of Autoclaving Cycles on the Cyclic Fatigue Resistance of Race and Race Evo Nickel-Titanium Endodontic Rotary Files: An In Vitro Study
    Almohareb, Rahaf A.
    Barakat, Reem
    Albakri, Aroob
    Altamimi, Manal
    METALS, 2021, 11 (12)
  • [47] A method to assess rotary nickel-titanium files
    Svec, TA
    Powers, JM
    JOURNAL OF ENDODONTICS, 2000, 26 (09) : 517 - 518
  • [48] Cleaning of rotary nickel-titanium endodontic instruments
    Linsuwanont, P
    Parashos, P
    Messer, HH
    INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (01) : 19 - 28
  • [49] Influence of heat treatment on torsional resistance and surface roughness of nickel-titanium instruments
    Silva, E. J. N. L.
    Giraldes, J. F. N.
    de Lima, C. O.
    Vieira, V. T. L.
    Elias, C. N.
    Antunes, H. S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (11) : 1645 - 1651
  • [50] Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
    Kim, H
    Johnson, JW
    ANGLE ORTHODONTIST, 1999, 69 (01) : 39 - 44