Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

被引:3
|
作者
Costa, Tatiana Dias [1 ]
da Fonseca e Silva, Elison [2 ]
Caetano, Paula Liparini [3 ]
da Silva Campos, Marcio Jose [3 ]
Resende, Leandro Marques [4 ]
Machado, Andre Guimaraes [1 ]
Resende do Carmo, Antonio Marcio [4 ]
机构
[1] Juiz de Fora Estacio Univ Ctr, Dept Endodont, Juiz De Fora, MG, Brazil
[2] Fed Inst Juiz de Fora, Dept Met Engn, Juiz De Fora, MG, Brazil
[3] Fed Inst Juiz de Fora, Dept Orthodont, Ivon Jose Cury 2, BR-36037467 Juiz De Fora, MG, Brazil
[4] Univ Fed Juiz de Fora, Dept Endodont, Juiz De Fora, MG, Brazil
来源
RESTORATIVE DENTISTRY AND ENDODONTICS | 2021年 / 46卷 / 01期
关键词
Corrosion; Endodontics; Root Canal; STAINLESS-STEEL; SODIUM-HYPOCHLORITE; ETHYLENEDIAMINETETRAACETIC ACID; TORSIONAL PROPERTIES; ROTARY INSTRUMENTS; SUSCEPTIBILITY; FATIGUE; ALLOYS;
D O I
10.5395/rde.2021.46.e6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickeltitanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (E-corr). The pitting potential (E-pit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for E-corr) and the Student t-test for independent samples (for E-pit). Results: The mean E-corr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with E-pit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effect of cryogenic treatment on nickel-titanium endodontic instruments
    Kim, JW
    Griggs, JA
    Regan, JD
    Ellis, RA
    Cai, Z
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (06) : 364 - 371
  • [22] Electropolishing Enhances the Resistance of Nickel-Titanium Rotary Files to Corrosion Fatigue-Failure in Hypochlorite
    Praisarnti, Chonrada
    Chang, Jeffrey W. W.
    Cheung, Gary S. P.
    JOURNAL OF ENDODONTICS, 2010, 36 (08) : 1354 - 1357
  • [23] Fracture resistance of electropolished rotary nickel-titanium endodontic instruments
    Anderson, Margot E.
    Price, John W. H.
    Parashos, Peter
    JOURNAL OF ENDODONTICS, 2007, 33 (10) : 1212 - 1216
  • [24] Machining efficiency and wear resistance of nickel-titanium endodontic flies
    Kazemi, RB
    Stenman, E
    Spangberg, LSW
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (05): : 596 - 602
  • [25] Effect of Cross-sectional Designs on Torsional Resistance of Endodontic Nickel-Titanium Files: A Finite Element Study
    Nanthaprathip, Natchaphon
    Morakul, Sarita
    Hiran-us, Sirawut
    Singhatanadgid, Pairod
    EUROPEAN JOURNAL OF DENTISTRY, 2024,
  • [26] Effect of heat treatment on transformation temperatures and bending properties of nickel-titanium endodontic instruments
    Yahata, Y.
    Yoneyama, T.
    Hayashi, Y.
    Ebihara, A.
    Doi, H.
    Hanawa, T.
    Suda, H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (07) : 621 - 626
  • [27] Blue Treatment Enhances Cyclic Fatigue Resistance of Vortex Nickel-Titanium Rotary Files
    Plotino, Gianluca
    Grande, Nicola M.
    Cotti, Elisabetta
    Testarelli, Luca
    Gambarini, Gianluca
    JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1451 - 1453
  • [28] Single File Reciprocating Technique Using Conventional Nickel-Titanium Rotary Endodontic Files
    Jin, So-Youn
    Lee, WooCheol
    Kang, Mo K.
    Hur, Bock
    Kim, Hyeon-Cheol
    SCANNING, 2013, 35 (06) : 349 - 354
  • [29] Effect of Different Heat-treated Nickel-Titanium Files on Vertical Root Fracture Resistance
    Furuncuoglu, Fatma
    Kalyoncuoglu, Elif
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2021, 22 (02): : 157 - 163
  • [30] Nickel-titanium files in endodontics: development, improvement, and modifications of nickel-titanium alloy
    Zivkovic, Slavoljub
    Jovanovic-Medojevic, Milica
    Neskovic, Jelena
    Popovic-Bajic, Marijana
    VOJNOSANITETSKI PREGLED, 2023, 80 (03) : 262 - 269