Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

被引:3
|
作者
Costa, Tatiana Dias [1 ]
da Fonseca e Silva, Elison [2 ]
Caetano, Paula Liparini [3 ]
da Silva Campos, Marcio Jose [3 ]
Resende, Leandro Marques [4 ]
Machado, Andre Guimaraes [1 ]
Resende do Carmo, Antonio Marcio [4 ]
机构
[1] Juiz de Fora Estacio Univ Ctr, Dept Endodont, Juiz De Fora, MG, Brazil
[2] Fed Inst Juiz de Fora, Dept Met Engn, Juiz De Fora, MG, Brazil
[3] Fed Inst Juiz de Fora, Dept Orthodont, Ivon Jose Cury 2, BR-36037467 Juiz De Fora, MG, Brazil
[4] Univ Fed Juiz de Fora, Dept Endodont, Juiz De Fora, MG, Brazil
来源
RESTORATIVE DENTISTRY AND ENDODONTICS | 2021年 / 46卷 / 01期
关键词
Corrosion; Endodontics; Root Canal; STAINLESS-STEEL; SODIUM-HYPOCHLORITE; ETHYLENEDIAMINETETRAACETIC ACID; TORSIONAL PROPERTIES; ROTARY INSTRUMENTS; SUSCEPTIBILITY; FATIGUE; ALLOYS;
D O I
10.5395/rde.2021.46.e6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickeltitanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (E-corr). The pitting potential (E-pit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for E-corr) and the Student t-test for independent samples (for E-pit). Results: The mean E-corr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with E-pit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Effect of phytic acid on chemical, structural, and mechanical characteristics of nickel-titanium endodontic files
    Samara, Mai
    Nassar, Mohannad
    Alqedairi, Abdullah
    Alfawaz, Hussam
    Jamleh, Ahmed
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [32] Laboratory Rational of Changes in the Crystal Lattice of Nickel-Titanium Endodontic Rotary Files in Autoclaving
    Khabadze, Zurab
    Mordanov, Oleg
    Balashova, Mariya
    Stolov, Leonid
    Pangratyan, Amaliya
    Bokova, Roza
    Nazhmudinov, Shamil
    Solimanov, Shamil
    Kuznetsova, Anastasiya
    Adzhieva, Anzhela
    Magomedov, Omargadzhi
    INTERNATIONAL JOURNAL OF DENTISTRY, 2020, 2020
  • [33] Electrochemical Dissolution of Nickel-Titanium Endodontic Files Induces Periodontal Ligament Cell Death
    Mitchell, Quinn
    Jeansonne, Billie Gail
    Stoute, Diana
    Lallier, Thomas E.
    JOURNAL OF ENDODONTICS, 2013, 39 (05) : 679 - 684
  • [34] Surface and cross-sectional characterization of titanium-nitride coated nickel-titanium endodontic files
    Al Jabbari, Youssef S.
    Koutsoukis, Theodoros
    Al Hadlaq, Suliman
    Berzins, David W.
    Zinelis, Spiros
    JOURNAL OF DENTAL SCIENCES, 2016, 11 (01) : 48 - 53
  • [35] Evaluation of success rate of endodontic treatment performed by students with stainless-steel K-files and nickel-titanium hand files
    Pettiette, MT
    Delano, EO
    Trope, M
    JOURNAL OF ENDODONTICS, 2001, 27 (02) : 124 - 127
  • [36] Low Environmental Temperature Influences the Fatigue Resistance of Nickel-titanium Files
    Shen, Ya
    Huang, Xiangya
    Wang, Zhejun
    Wei, Xi
    Haapasalo, Markus
    JOURNAL OF ENDODONTICS, 2018, 44 (04) : 626 - 629
  • [37] Effect of sterilization on torsional fracture resistance of nickel-titanium rotary files
    Kiss, EP
    Murchison, DF
    Davis, BD
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 547 - 547
  • [38] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files
    Elnaghy, A. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (11) : 1034 - 1039
  • [39] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files
    Lee, S. W.
    Park, Y. G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (11) : 1100 - 1100
  • [40] Heat treatment of nickel-titanium rotary endodontic instruments: effects on bending properties and shaping abilities
    Ebihara, A.
    Yahata, Y.
    Miyara, K.
    Nakano, K.
    Hayashi, Y.
    Suda, H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (09) : 843 - 849