Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

被引:3
|
作者
Costa, Tatiana Dias [1 ]
da Fonseca e Silva, Elison [2 ]
Caetano, Paula Liparini [3 ]
da Silva Campos, Marcio Jose [3 ]
Resende, Leandro Marques [4 ]
Machado, Andre Guimaraes [1 ]
Resende do Carmo, Antonio Marcio [4 ]
机构
[1] Juiz de Fora Estacio Univ Ctr, Dept Endodont, Juiz De Fora, MG, Brazil
[2] Fed Inst Juiz de Fora, Dept Met Engn, Juiz De Fora, MG, Brazil
[3] Fed Inst Juiz de Fora, Dept Orthodont, Ivon Jose Cury 2, BR-36037467 Juiz De Fora, MG, Brazil
[4] Univ Fed Juiz de Fora, Dept Endodont, Juiz De Fora, MG, Brazil
来源
RESTORATIVE DENTISTRY AND ENDODONTICS | 2021年 / 46卷 / 01期
关键词
Corrosion; Endodontics; Root Canal; STAINLESS-STEEL; SODIUM-HYPOCHLORITE; ETHYLENEDIAMINETETRAACETIC ACID; TORSIONAL PROPERTIES; ROTARY INSTRUMENTS; SUSCEPTIBILITY; FATIGUE; ALLOYS;
D O I
10.5395/rde.2021.46.e6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickeltitanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (E-corr). The pitting potential (E-pit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for E-corr) and the Student t-test for independent samples (for E-pit). Results: The mean E-corr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with E-pit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Wear resistance of nickel-titanium endodontic files after surface treatment
    Alves-Claro, A. P. R.
    Claro, F. A. E.
    Uzumaki, E. T.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (10) : 3273 - 3277
  • [2] Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    Silvaggio, J
    Hicks, ML
    JOURNAL OF ENDODONTICS, 1997, 23 (12) : 731 - 734
  • [3] Heat Treatment and Surface Treatment of Nickel-Titanium Endodontic Instruments
    Kwak, Sang Won
    Shen, Ya
    Liu, He
    Wang, Zhejun
    Kim, Hyeon-Cheol
    Haapasalo, Markus
    FRONTIERS IN DENTAL MEDICINE, 2021, 2
  • [4] Torsional properties of stainless steel and nickel-titanium endodontic files
    Rowan, MB
    Nicholls, JI
    Steiner, J
    JOURNAL OF ENDODONTICS, 1996, 22 (07) : 341 - 345
  • [5] Cutting efficiency of different nickel-titanium endodontic files.
    Beer, R. F.
    Stelzner, R. S.
    Gaengler, P.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B131 - B131
  • [6] Multiscale characterization of nickel-titanium alloy used for endodontic files
    Serres, N.
    Bahlouli, N.
    Hemmerle, J.
    Wagner-Kocher, C.
    Correia, P. de Magalhaes
    Fabre, R.
    Jordan, L.
    Haikel, Y.
    Feugeas, F.
    JA 2013 - JOURNEES ANNUELLES DE LA SF2M 2013 / SF2M ANNUAL MEETING 2013, 2013, 7
  • [7] Influence of heat-treatment on torsional resistance to fracture of nickel-titanium endodontic instruments.
    Lo Savio, F.
    Pedulla, E.
    Rapisarda, E.
    La Rosa, G.
    21ST EUROPEAN CONFERENCE ON FRACTURE, (ECF21), 2016, 2 : 1311 - 1318
  • [8] Corrosion in stainless-steel and nickel-titanium files
    Stokes, OW
    Di Fiore, PM
    Barss, JT
    Koerber, A
    Gilbert, JL
    Lautenschlager, EP
    JOURNAL OF ENDODONTICS, 1999, 25 (01) : 17 - 20
  • [9] Wear resistance of nickel–titanium endodontic files after surface treatment
    A. P. R. Alves-Claro
    F. A. E. Claro
    E. T. Uzumaki
    Journal of Materials Science: Materials in Medicine, 2008, 19
  • [10] Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files
    Rapisarda, E
    Bonaccorso, A
    Tripi, TR
    Condorelli, GG
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (03): : 343 - 347