Influence of lubricating oil circulation characteristics on the performance of electric vehicle heat pump system under low temperature conditions

被引:8
|
作者
Li, Kang [1 ,2 ]
Kong, Fanyue [1 ]
Luo, Shuxian [3 ]
Liu, Ni [1 ]
Zhang, Hua [1 ]
Dou, Binlin [1 ]
Zhao, Yugang [1 ]
Zhou, Xuejin [5 ]
Tu, Ran [5 ]
Su, Lin [1 ]
He, Qize [4 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Key Lab Multiphase Flow & Heat Transfer Shanghai P, Shanghai 200093, Peoples R China
[3] Pan Asia Tech Automot Ctr Co Ltd, Shanghai 201201, Peoples R China
[4] Shanghai Fire Res Inst MEM, Shanghai 200093, Peoples R China
[5] Huaqiao Univ, Coll Mech Engn & Automat, Xiamen 361021, Fujian, Peoples R China
关键词
Electric vehicle; Oil retention; Heat pump system; Oil circulation rate; Heat pump performance; FROST GROWTH; SURFACE; FIN;
D O I
10.1016/j.applthermaleng.2023.121601
中图分类号
O414.1 [热力学];
学科分类号
摘要
Electric vehicles frequently employ heat pump systems for winter heating. In winter low-temperature environments, the viscosity of lubricating oil increases, forming an oil film as the refrigerant enters the heat exchanger, consequently impacting the heat transfer efficiency and overall performance of the heat pump system. This paper presents the design and implementation of an experimental heat pump system tailored for electric vehicles. The experimental setup incorporates a specialized device for lubricating oil sampling and an assessment methodology for evaluating heat pump functionality. Under a range of low-temperature conditions, the system underwent comprehensive testing, enabling a detailed analysis and synthesis of the flow characteristics and the influence of lubricating oil within both the heat pump system and the heat exchanger. The results reveal that the oil circulation rate is directly affected by the compressor oil charge, and maintaining the oil circulation rate within the range of 3 %-4 % results in a peak COP of the system. When the ambient temperature is 0 degree celsius and the oil filling volume is 200 g, the oil circulation rate is 3.87 %, and the COP can reach 1.93. In addition, as the oil retention in the evaporator increases by 15.67 g, the COP value decreases by 21 %. Similarly, the increase in oil retention in the condenser from 2.43 g to 6.25 g resulted in a corresponding decrease in heat transfer capacity of 0.07 kW/K, leading to an overall deterioration of the system's performance.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] The Performance Test of Heat Exchanger Under Low-temperature Frosting Conditions
    Wang Zhiyuan
    Tong Zhiwen
    2013 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS), 2013, : 286 - 289
  • [42] Experimeatal analysis on application of heat source tower heat pump system under low temperature condition
    Huang Y.
    Ge F.
    Hu Z.
    Qin H.
    Yang Y.
    Zheng H.
    Ge, Fenghua (gfhgq@126.com), 1600, Science Press (42): : 260 - 266
  • [43] Battery thermal management strategy utilizing a secondary heat pump in electric vehicle under cold-start conditions
    Lee, Sangwook
    Chung, Yoong
    Lee, Yoo Il
    Jeong, Yeonwoo
    Kim, Min Soo
    ENERGY, 2023, 269
  • [44] Study on electric vehicle thermal management system using phase change materials and CO2 heat pump waste heat recovery under cold conditions
    Li, Kexin
    Shi, Lingfeng
    Zhang, Yonghao
    Yao, Yu
    Zhang, Chong
    Tian, Hua
    Shu, Gequn
    APPLIED THERMAL ENGINEERING, 2024, 252
  • [45] Thermo-hydraulic behavior and flow boiling characteristics of R290 in plate heat exchangers for electric vehicle heat pump applications under cold climatic conditions
    Dhamodharan, Palanisamy
    Salman, Mohammad
    Prabakaran, Rajendran
    Kim, Sung Chul
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 235
  • [46] Switched control strategy and performance test of electric vehicle electric power steering system under different conditions
    Zhao, Jing-Bo
    Zhou, Bing
    Li, Xiu-Lian
    Bei, Shao-Yi
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2013, 17 (11): : 105 - 109
  • [47] Investigation on the performance enhancement of electric vehicle heat pump system with air-to-air regenerative heat exchanger in cold condition
    Sangwook, Lee
    Yoong, Chung
    Yeonwoo, Jeong
    Soo, Kim Min
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 50
  • [48] Heating performance characteristics of CO2 heat pump system for electrical vehicle in a cold climate
    Wang, Dandong
    Yu, Bingbing
    Hu, Jichao
    Chen, Liang
    Shi, Junye
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 85 : 27 - 41
  • [49] The Influence of Hydraulic Characteristics on Structural Performance in a Pump-Turbine under No-Load Conditions
    Ren, Shenming
    Zheng, Yuan
    Yuan, Cong
    Liu, Bin
    Fernandez-Rodriguez, Emmanuel
    Zhang, Yuquan
    PROCESSES, 2023, 11 (12)
  • [50] Analysis on the performance of low-load feed water heating system with jet heat pump under variable working conditions
    Li B.
    Zhang G.
    Chen W.
    Liu J.
    Liu, Jiping, 1600, Xi'an Jiaotong University (51): : 65 - 71