Influence of lubricating oil circulation characteristics on the performance of electric vehicle heat pump system under low temperature conditions

被引:8
|
作者
Li, Kang [1 ,2 ]
Kong, Fanyue [1 ]
Luo, Shuxian [3 ]
Liu, Ni [1 ]
Zhang, Hua [1 ]
Dou, Binlin [1 ]
Zhao, Yugang [1 ]
Zhou, Xuejin [5 ]
Tu, Ran [5 ]
Su, Lin [1 ]
He, Qize [4 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Key Lab Multiphase Flow & Heat Transfer Shanghai P, Shanghai 200093, Peoples R China
[3] Pan Asia Tech Automot Ctr Co Ltd, Shanghai 201201, Peoples R China
[4] Shanghai Fire Res Inst MEM, Shanghai 200093, Peoples R China
[5] Huaqiao Univ, Coll Mech Engn & Automat, Xiamen 361021, Fujian, Peoples R China
关键词
Electric vehicle; Oil retention; Heat pump system; Oil circulation rate; Heat pump performance; FROST GROWTH; SURFACE; FIN;
D O I
10.1016/j.applthermaleng.2023.121601
中图分类号
O414.1 [热力学];
学科分类号
摘要
Electric vehicles frequently employ heat pump systems for winter heating. In winter low-temperature environments, the viscosity of lubricating oil increases, forming an oil film as the refrigerant enters the heat exchanger, consequently impacting the heat transfer efficiency and overall performance of the heat pump system. This paper presents the design and implementation of an experimental heat pump system tailored for electric vehicles. The experimental setup incorporates a specialized device for lubricating oil sampling and an assessment methodology for evaluating heat pump functionality. Under a range of low-temperature conditions, the system underwent comprehensive testing, enabling a detailed analysis and synthesis of the flow characteristics and the influence of lubricating oil within both the heat pump system and the heat exchanger. The results reveal that the oil circulation rate is directly affected by the compressor oil charge, and maintaining the oil circulation rate within the range of 3 %-4 % results in a peak COP of the system. When the ambient temperature is 0 degree celsius and the oil filling volume is 200 g, the oil circulation rate is 3.87 %, and the COP can reach 1.93. In addition, as the oil retention in the evaporator increases by 15.67 g, the COP value decreases by 21 %. Similarly, the increase in oil retention in the condenser from 2.43 g to 6.25 g resulted in a corresponding decrease in heat transfer capacity of 0.07 kW/K, leading to an overall deterioration of the system's performance.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Research on Control Strategy of Electric Vehicle Heat Pump Air Conditioning System in Low Temperature Environment
    Cheng, Anyu
    Xu, Chenchen
    Long, Tianci
    PROCEEDINGS OF THE 33RD CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2021), 2021, : 7433 - 7437
  • [12] Use of a Thermal Battery with a Heat Pump for Low Temperature Electric Vehicle Operation
    Jeffs, James
    McGordon, Andrew
    Widanage, W. Dhammika
    Robinson, Simon
    Picarelli, Alessandro
    2017 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2017,
  • [13] Heating Performance Characteristics of an Electric Vehicle Heat Pump Air Conditioning System Based on Exergy Analysis
    Tang, Xingwang
    Guo, Qin
    Li, Ming
    Jiang, Mingzhe
    ENERGIES, 2020, 13 (11)
  • [14] Enhance the heating performance of an electric vehicle AC/HP system under low temperature
    Wang, Zhixing
    Wei, Mingshan
    Guo, Chong
    Zhao, Meng
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 2384 - 2389
  • [15] Performance evaluation of propane heat pump system for electric vehicle in cold climate
    Liu, Cichong
    Zhang, Yun
    Gao, Tianyuan
    Shi, Junye
    Chen, Jiangping
    Wang, Tianying
    Pan, Leyan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 95 : 51 - 60
  • [16] Hybrid Electric vehicle Performance Analysis under Various Temperature Conditions
    Panday, Aishwarya
    Bansal, Hari Om
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1962 - 1967
  • [17] Study on the performance of heat pump drying system under the synergistic effect of humidity enthalpy enhancement and solar heat storage under low temperature working conditions
    Zhang, Zude
    Li, Ming
    Wang, Yunfeng
    Li, Guoliang
    Xing, Tianyu
    Yao, Muchi
    Hassanien, Emam
    APPLIED THERMAL ENGINEERING, 2024, 244
  • [18] Influence of Heat Exchanger Tube Layout on Performance of Heat Pump System for Electric Cars
    Zhang, Xiaoqiang
    Xue, Qingfeng
    Zou, Huiming
    Liu, Jixuan
    Tian, Changqing
    Zhang, Xuelai
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 5085 - 5090
  • [19] An experimental investigation of oil circulation ratio influence on heating performance in an air condition heat pump system for electrical vehicles
    Li, Kang
    Luo, Shuxian
    Wang, Zhenzhen
    Zhang, Hua
    Su, Lin
    Fang, Yidong
    Zhou, Xuejin
    Zhang, Huiqi
    Tu, Ran
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 122 : 220 - 231
  • [20] INFLUENCE OF ELECTRONIC EXPANSION VALVE ON HEATING PERFORMANCE OF VEHICLE HEAT PUMP SYSTEM
    Su, Zhiyong
    Li, Haijun
    Liu, Lei
    Qin, Xingduo
    An, Tong
    Zhao, Chaoyue
    THERMAL SCIENCE, 2023, 27 (3A): : 1819 - 1826