Influence of lubricating oil circulation characteristics on the performance of electric vehicle heat pump system under low temperature conditions

被引:8
|
作者
Li, Kang [1 ,2 ]
Kong, Fanyue [1 ]
Luo, Shuxian [3 ]
Liu, Ni [1 ]
Zhang, Hua [1 ]
Dou, Binlin [1 ]
Zhao, Yugang [1 ]
Zhou, Xuejin [5 ]
Tu, Ran [5 ]
Su, Lin [1 ]
He, Qize [4 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Key Lab Multiphase Flow & Heat Transfer Shanghai P, Shanghai 200093, Peoples R China
[3] Pan Asia Tech Automot Ctr Co Ltd, Shanghai 201201, Peoples R China
[4] Shanghai Fire Res Inst MEM, Shanghai 200093, Peoples R China
[5] Huaqiao Univ, Coll Mech Engn & Automat, Xiamen 361021, Fujian, Peoples R China
关键词
Electric vehicle; Oil retention; Heat pump system; Oil circulation rate; Heat pump performance; FROST GROWTH; SURFACE; FIN;
D O I
10.1016/j.applthermaleng.2023.121601
中图分类号
O414.1 [热力学];
学科分类号
摘要
Electric vehicles frequently employ heat pump systems for winter heating. In winter low-temperature environments, the viscosity of lubricating oil increases, forming an oil film as the refrigerant enters the heat exchanger, consequently impacting the heat transfer efficiency and overall performance of the heat pump system. This paper presents the design and implementation of an experimental heat pump system tailored for electric vehicles. The experimental setup incorporates a specialized device for lubricating oil sampling and an assessment methodology for evaluating heat pump functionality. Under a range of low-temperature conditions, the system underwent comprehensive testing, enabling a detailed analysis and synthesis of the flow characteristics and the influence of lubricating oil within both the heat pump system and the heat exchanger. The results reveal that the oil circulation rate is directly affected by the compressor oil charge, and maintaining the oil circulation rate within the range of 3 %-4 % results in a peak COP of the system. When the ambient temperature is 0 degree celsius and the oil filling volume is 200 g, the oil circulation rate is 3.87 %, and the COP can reach 1.93. In addition, as the oil retention in the evaporator increases by 15.67 g, the COP value decreases by 21 %. Similarly, the increase in oil retention in the condenser from 2.43 g to 6.25 g resulted in a corresponding decrease in heat transfer capacity of 0.07 kW/K, leading to an overall deterioration of the system's performance.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Performance characteristics of the direct spray oil cooling system for a driving motor of an electric vehicle
    Garud, Kunal Sandip
    Hwang, Seong-Guk
    Han, Jeong-Woo
    Lee, Moo-Yeon
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 196
  • [32] Study on dynamic characteristics of centrifugal pump with the development of cavitation under low temperature conditions
    Zhang, Linhua
    Ge, Bingxin
    Meng, Fanguang
    Song, Yongxing
    Liu, Jingting
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (06)
  • [33] LOW-TEMPERATURE CHARACTERISTICS OF INSULATING OIL UNDER EXTREMELY COLD CONDITIONS
    HOLMBERG, N
    JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1980, 25 (11): : 721 - 724
  • [34] Low temperature pyrolysis characteristics of oil sludge under various heating conditions
    Wang, Zhiqi
    Guo, Qingjie
    Liu, Xinmin
    Cao, Changqing
    ENERGY & FUELS, 2007, 21 (02) : 957 - 962
  • [35] Experimental Investigation on Heating Performance of Heat Pump for Electric Vehicles in Low Ambient Temperature.
    Qin, Fei
    Shao, Shuangquan
    Tian, Changqing
    Yang, Hongxing
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 726 - 729
  • [36] Performance evaluation of R1234yf heat pump system for an electric vehicle in cold climate
    Li, Wanyong
    Liu, Rui
    Liu, Yusheng
    Wang, Dandong
    Shi, Junye
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 : 117 - 125
  • [37] Performance research on a CO2 heat pump system with novel control strategy in electric vehicle
    Teng, Haixu
    Wang, Jun
    Wang, Yuncong
    Song, Zhanzhuo
    Liu, Dong
    Liu, Zhikun
    Xue, Xiaoye
    Chang, Wei
    Li, Ming
    APPLIED THERMAL ENGINEERING, 2025, 259
  • [38] Study on drying characteristics of sludge under different conditions based on the low-temperature sludge heat pump drying model
    Hu, Anjie
    Ma, Lina
    Liu, Dong
    Jiang, Li
    Wang, Zhenyu
    Wang, Ling
    JOURNAL OF CLEANER PRODUCTION, 2024, 450
  • [39] Heat Transfer Characteristics of an Electric Motor with Oil-Dripping Cooling under Overload Conditions
    Kang, Eun-Hyeok
    Garud, Kunal Sandip
    Park, Su Cheong
    Lee, Moo-Yeon
    SYMMETRY-BASEL, 2024, 16 (03):
  • [40] Experimental study on low temperature heating performance of different vapor injection heat pump systems equipped with a flash tank and economizers for electric vehicle
    Li, Kang
    Ma, Jingru
    Zhang, Bin
    Su, Lin
    Liu, Ni
    Zhang, Hua
    Dou, Binlin
    He, Qize
    Zhou, Xuejin
    Tu, Ran
    APPLIED THERMAL ENGINEERING, 2023, 227