Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

被引:10
|
作者
Khatri, Kavin [1 ]
Sharma, Vijay [2 ]
Farooque, Kamran [2 ]
Tiwari, Vivek [2 ]
机构
[1] Baba Farid Univ Hlth Sci, GGS Med Coll Faridkot, Dept Orthopaed, Faridkot, India
[2] All India Inst Med Sci, Dept Orthopaed, Jai Prakash Narayan Apex Trauma Ctr, Delhi, India
关键词
Bone Plates; Radius; Volar Plate; Fracture Fixation; Internal; Injury; Wrist;
D O I
10.5812/atr.25174
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. Objectives: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. Patients and Methods: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 +/- 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 +/- 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley's demerit scoring system was used to assess the final outcome. Results: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. Conclusions: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate
    Stefan Quadlbauer
    Ch. Pezzei
    J. Jurkowitsch
    R. Rosenauer
    A. Pichler
    S. Schättin
    T. Hausner
    M. Leixnering
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 1773 - 1782
  • [42] Volar locking plate vs epibloc system for distal radius fractures in the elderly
    Solarino, Giuseppe
    Vicenti, Giovanni
    Abate, Antonella
    Carrozzo, Massimiliano
    Picca, Girolamo
    Colella, Antonio
    Moretti, Biagio
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S84 - S90
  • [43] Intraarticular Distal End Radius Fractures Treated with Volar Locking Plate Variations
    Gaonkar, Nishant
    Patil, Nitin
    Kolekar, Anupam
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1030 - S1032
  • [44] Prospective study of distal radius fractures treated with a volar locking plate system
    Osada, Denju
    Kamei, Shuzo
    Masuzaki, Koichiro
    Takai, Morimitsu
    Kameda, Masahiro
    Tamai, Kazuya
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (05): : 691 - 700
  • [45] Treatment of distal clavicle fracture with distal radius volar locking compression plate
    Yu Chao
    Sun Yue-hua
    Zhao Chang-qing
    Shi Ding-wei
    Wang You
    CHINESE JOURNAL OF TRAUMATOLOGY, 2009, 12 (05) : 299 - 301
  • [46] Volar Locking Plate Fixation for Distal Radius Fractures Distal to the Watershed Line with an Intact Lunate Volar Rim
    Cha, Soo Min
    Shin, Hyun Dae
    Kim, Seung Won
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (06): : 708 - 716
  • [47] Clinical Results of Volar Locking Plate for Distal Radius Fractures: Conventional versus Minimally Invasive Plate Osteosynthesis
    Zenke, Yukichi
    Sakai, Akinori
    Oshige, Toshihisa
    Moritani, Shiro
    Fuse, Yoshifumi
    Maehara, Takashi
    Nakamura, Toshitaka
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (07) : 425 - 431
  • [48] Treatment of distal clavicle fracture with distal radius volar locking compression plate
    俞超
    孙月华
    赵长清
    史定伟
    王友
    中华创伤杂志(英文版), 2009, (05) : 299 - 301
  • [49] Clinical and Radiological Results after Distal Radius Fracture: Intramedullary Locking Nail versus Volar Locking Plate Osteosynthesis
    Lerch, S.
    Sextro, H. -G.
    Wilken, F.
    Wittenberg, C. E.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2009, 147 (05): : 547 - 552
  • [50] Outcomes of minimally invasive plate osteosynthesis (MIPO) with volar locking plates in distal radius fractures: A review
    Liverneaux, P.
    Ichihara, S.
    Facca, S.
    Diaz, J. J. Hidalgo
    HAND SURGERY & REHABILITATION, 2016, 35 : S80 - S85