Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

被引:10
|
作者
Khatri, Kavin [1 ]
Sharma, Vijay [2 ]
Farooque, Kamran [2 ]
Tiwari, Vivek [2 ]
机构
[1] Baba Farid Univ Hlth Sci, GGS Med Coll Faridkot, Dept Orthopaed, Faridkot, India
[2] All India Inst Med Sci, Dept Orthopaed, Jai Prakash Narayan Apex Trauma Ctr, Delhi, India
关键词
Bone Plates; Radius; Volar Plate; Fracture Fixation; Internal; Injury; Wrist;
D O I
10.5812/atr.25174
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. Objectives: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. Patients and Methods: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 +/- 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 +/- 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley's demerit scoring system was used to assess the final outcome. Results: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. Conclusions: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures
    Usta, Emirhan
    Akpolat, Ahmet O.
    Kahraman, Ahmet N.
    Kara, Adnan
    Oc, Yunus
    Kilinc, Bekir E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [22] Breakage of volar locking plate system for distal radius fractures
    Kawanishi, Syohei
    Gato, Uasushi
    Nakai, Tsuyoshi
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 1): : 71 - 77
  • [23] Locked volar plating for unstable distal radial fractures: Clinical and radiological outcomes
    Knight, Dominique
    Hajducka, Carol
    Will, Elizabeth
    McQueen, Margaret
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 184 - 189
  • [24] Biomechanical Analysis of a Volar Variable-Angle Locking Plate: The Effect of Capturing a Distal Radial Styloid Fragment
    Stanbury, Spencer J.
    Salo, Art
    Elfar, John C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (12): : 2488 - 2494
  • [25] Role of Pronator Quadratus Repair in Volar Locking Plate Treatment of Distal Radius Fractures
    Zhang, Dafang
    Meyer, Maximilian A.
    Earp, Brandon E.
    Blazar, Philip
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (15) : 696 - 702
  • [26] Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient
    Orbay, JL
    Fernandez, DL
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (01): : 96 - 102
  • [27] Complications after volar locking plate fixation of distal radius fractures
    Johnson, N. A.
    Cutler, L.
    Dias, J. J.
    Ullah, A. S.
    Wildin, C. J.
    Bhowal, B.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (03): : 528 - 533
  • [28] Volar locking compression T-plate for distal radius fractures
    Lattmann, T
    Dietrich, M
    Meier, C
    Kilgus, M
    Platz, A
    BRITISH JOURNAL OF SURGERY, 2005, 92 (07) : 905 - 905
  • [29] Complications of Distal Radius Fractures Treated by Volar Locking Plate Fixation
    Satake, Hiroshi
    Hanaka, Naomi
    Honma, Ryusuke
    Watanabe, Tadayoshi
    Inoue, Shigeru
    Kanauchi, Yumiko
    Kato, Yoshihiro
    Nakajima, Taku
    Sato, Daisuke
    Eto, Jun
    Maruyama, Masahiro
    Naganuma, Yasushi
    Sasaki, Junya
    Toyono, Shuji
    Harada, Mikio
    Ishigaki, Daisuke
    Takahara, Masatoshi
    Takagi, Michiaki
    ORTHOPEDICS, 2016, 39 (05) : E893 - E896
  • [30] Complication Rate Comparing Variable Angle Distal Locking Plate to Fixed Angle Plate Fixation of Distal Radius Fractures
    Mehrzad, Raman
    Kim, David C.
    ANNALS OF PLASTIC SURGERY, 2016, 77 (06) : 623 - 625