Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

被引:10
|
作者
Khatri, Kavin [1 ]
Sharma, Vijay [2 ]
Farooque, Kamran [2 ]
Tiwari, Vivek [2 ]
机构
[1] Baba Farid Univ Hlth Sci, GGS Med Coll Faridkot, Dept Orthopaed, Faridkot, India
[2] All India Inst Med Sci, Dept Orthopaed, Jai Prakash Narayan Apex Trauma Ctr, Delhi, India
关键词
Bone Plates; Radius; Volar Plate; Fracture Fixation; Internal; Injury; Wrist;
D O I
10.5812/atr.25174
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. Objectives: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. Patients and Methods: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 +/- 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 +/- 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley's demerit scoring system was used to assess the final outcome. Results: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. Conclusions: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Distal radius volar locking plates: Does a variable angle locking system confer a clinical advantage ?
    Marlow, William J.
    Singhal, Rohit
    Dheerendra, Sujay
    Ralte, Peter
    Fischer, Jochen
    Waseem, Mohammad
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (03): : 309 - 316
  • [32] Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures
    Arora, R
    Lutz, M
    Fritz, D
    Zimmermann, R
    Oberladstätter, J
    Gabl, M
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (06) : 399 - 404
  • [33] Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures
    R. Arora
    M. Lutz
    D. Fritz
    R. Zimmermann
    J. Oberladstätter
    M. Gabl
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 399 - 404
  • [34] A comparative study of clinical and radiological outcomes of dorsally angulated, unstable distal radius fractures in elderly patients: Intrafocal pinning versus volar locking plating
    Oshige, Toshihisa
    Sakai, Akinori
    Zenke, Yukichi
    Moritani, Shiro
    Nakamura, Toshitaka
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (09): : 1385 - 1392
  • [35] Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
    Kumbaraci M.
    Kucuk L.
    Karapinar L.
    Kurt C.
    Coskunol E.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 173 - 178
  • [36] Comparison of the Orientation Angles of Volar Locking Plate Distal Ulnar Locking Screw for Distal Radius Fractures
    Abe, Shingo
    Shimada, Toshiki
    Murase, Tsuyoshi
    Kuriyama, Kohji
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 389.e1 - 389.e13
  • [37] Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results
    Markus Figl
    Patrick Weninger
    Michael Liska
    Marcus Hofbauer
    Martin Leixnering
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 661 - 669
  • [38] Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results
    Figl, Markus
    Weninger, Patrick
    Liska, Michael
    Hofbauer, Marcus
    Leixnering, Martin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (05) : 661 - 669
  • [39] Ten years of volar locking plate fixation in the treatment of distal radius fractures: who benefits?
    Loegters, Tim
    Schaedel-Hoepfner, Michael
    Windolf, Joachim
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2012, 7 (04): : 200 - 208
  • [40] Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate
    Quadlbauer, Stefan
    Pezzei, Ch.
    Jurkowitsch, J.
    Rosenauer, R.
    Pichler, A.
    Schaettin, S.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (12) : 1773 - 1782