RELIABILITY OF INTRAOCULAR-PRESSURE MEASUREMENT WITH THE GOLDMANN APPLANATION TONOMETER IN EPIDEMIOLOGIC STUDIES

被引:153
|
作者
DIELEMANS, I
VINGERLING, JR
HOFMAN, A
GROBBEE, DE
DEJONG, PTVM
机构
[1] ERASMUS UNIV ROTTERDAM,SCH MED,DEPT OPHTALMOL,3000 DR ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV ROTTERDAM,SCH MED,DEPT EPIDEMIOL & BIOSTAT,3000 DR ROTTERDAM,NETHERLANDS
关键词
D O I
10.1007/BF00176782
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The reproducibility of intraocular pressure (IOP) measurement with the Goldmann applanation tonometer was investigated as part of a population-based epidemiological study. Sixty-two subjects were examined in a first measurement session. The IOP was measured three times consecutively in both eyes according to a fixed protocol. The mean standard deviation (SD) of these measurements was 0.8 mmHg. The mean intra-observer variation for the first measurement was 1.64 (SD 2.07) mmHg. For the median of the three measurements the intra-observer variation was 1.50 (SD 1.96) mmHg. The mean inter-observer values were 1.79 (SD 2.41) mmHg for the first measurement and 1.60 (SD 2.15) mmHg for the median measurement. The correlation coefficient between the median values of the three measurements of both observers was 0.81. No systematic differences were found between the two observers. Using the median value of three consecutive measurements reduced the inter-observer variation by 11% and the intra-observer variation by 9% compared with a single measurement.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 50 条
  • [41] Comparative study of recording intraocular pressure in adults by three different tonometers Goldmann applanation tonometer, noncontact tonometer, and tonopen
    Manade, Varsha V.
    Kotecha, Megha R.
    Chodvadiya, Surbhi A.
    Ta, Jhimli
    Paranjpe, Radhika R.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (01) : 39 - 42
  • [42] Comparison of intraocular pressure measurements obtained by icare pro tonometer, non-contact tonometer and Goldmann applanation tonometer in healthy individuals
    Duran, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (10): : 1195 - 1203
  • [43] Study of Accuracy of Intraocular Pressure measured by non-contact (air puff) Tonometer confirmed by Goldmann Applanation Tonometer
    Dibaji, Mohammad
    Shaikh, Rehan Moinuddin
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (03): : 972 - 974
  • [44] Influence of Corneal Biomechanical Properties on Intraocular Pressure Differences Between an Air-Puff Tonometer and the Goldmann Applanation Tonometer
    Tranchina, Laura
    Lombardo, Marco
    Oddone, Francesco
    Serrao, Sebastiano
    Lomoriello, Domenico Schiano
    Ducoli, Pietro
    JOURNAL OF GLAUCOMA, 2013, 22 (05) : 416 - 421
  • [45] Clinical comparison of ocular blood flow tonometer, tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes
    Rao, VJ
    Gnanaraj, L
    Mitchell, KW
    Figueiredo, FC
    CORNEA, 2001, 20 (08) : 834 - 838
  • [46] Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review [Response To Letter]
    De Bernardo, Maddalena
    Cembalo, Giovanni
    Rosa, Nicola
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2981 - 2982
  • [47] AUTOMATIC-MEASUREMENT OF INTRAOCULAR-PRESSURE WITH AN ELECTRONIC SENSOR TONOMETER
    DRAEGER, J
    HECHLER, B
    LEVEDAG, S
    WIRT, H
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1987, 190 (06) : 539 - 541
  • [48] INTRAOCULAR-PRESSURE MEASUREMENT IN CHILDREN USING THE KEELER PULSAIR TONOMETER
    EVANS, K
    WISHART, PK
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1992, 12 (03) : 287 - 290
  • [49] Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer
    Saleh, Tarek A.
    Adams, Morag
    McDermott, Bill
    Claridge, Kate G.
    Ewings, Paul
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (06): : 516 - 520
  • [50] LACK OF EFFECTS OF ANESTHETIC ON MEASUREMENT OF INTRAOCULAR-PRESSURE BY GOLDMANN TONOMETRY
    JOSE, JG
    BASTA, M
    CRAMER, KJ
    FAIN, M
    TURETSKY, D
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1983, 60 (04): : 308 - 310