RELIABILITY OF INTRAOCULAR-PRESSURE MEASUREMENT WITH THE GOLDMANN APPLANATION TONOMETER IN EPIDEMIOLOGIC STUDIES

被引:153
|
作者
DIELEMANS, I
VINGERLING, JR
HOFMAN, A
GROBBEE, DE
DEJONG, PTVM
机构
[1] ERASMUS UNIV ROTTERDAM,SCH MED,DEPT OPHTALMOL,3000 DR ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV ROTTERDAM,SCH MED,DEPT EPIDEMIOL & BIOSTAT,3000 DR ROTTERDAM,NETHERLANDS
关键词
D O I
10.1007/BF00176782
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The reproducibility of intraocular pressure (IOP) measurement with the Goldmann applanation tonometer was investigated as part of a population-based epidemiological study. Sixty-two subjects were examined in a first measurement session. The IOP was measured three times consecutively in both eyes according to a fixed protocol. The mean standard deviation (SD) of these measurements was 0.8 mmHg. The mean intra-observer variation for the first measurement was 1.64 (SD 2.07) mmHg. For the median of the three measurements the intra-observer variation was 1.50 (SD 1.96) mmHg. The mean inter-observer values were 1.79 (SD 2.41) mmHg for the first measurement and 1.60 (SD 2.15) mmHg for the median measurement. The correlation coefficient between the median values of the three measurements of both observers was 0.81. No systematic differences were found between the two observers. Using the median value of three consecutive measurements reduced the inter-observer variation by 11% and the intra-observer variation by 9% compared with a single measurement.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 50 条
  • [21] Red-free light for measurement of intraocular pressure using Goldmann applanation tonometer without fluorescein
    Ghoneim, Ehab M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (01) : 84 - 87
  • [22] Comparison of intraocular pressure measurements with the digital tonometer TGDc-01 'PRA' and the Goldmann applanation tonometer
    Meyer, MW
    Gockeln, R
    Hoy, L
    Meyer, A
    Erb, C
    OPHTHALMIC RESEARCH, 2004, 36 (05) : 250 - 254
  • [23] Comparison of intraocular pressure obtained by Goldmann applanation tonometer, Corvis ST and an airpuff tonometer in healthy adults
    Karmiris, Efthymios
    Tsiripidis, Konstantinos
    Gartaganis, Panos S.
    Totou, Styliani
    Vasilopoulou, Maria-Giannoula
    Patelis, Andreas
    Giannakis, Ioannis
    Chalkiadaki, Evangelia
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (02) : 951 - 959
  • [24] A comparison of intraocular pressure values obtained using a Goldmann applanation tonometer and a handheld version of applanation resonance tonometer: A preliminary report
    Mulak, Malgorzata
    Czak, Wojciech A.
    Mimier, Malgorzata
    Kaczmarek, Radoslaw
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 27 (04): : 481 - 485
  • [25] Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    Lösch, A
    Scheuerle, A
    Rupp, V
    Auffarth, G
    Becker, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (04) : 313 - 316
  • [26] Comparison of Disposable Goldmann Applanation Tonometer, ICare ic100, and Tonopen XL to Standards of Care Goldmann Nondisposable Applanation Tonometer for Measuring Intraocular Pressure
    Wong, Benny
    Parikh, Deep
    Rosen, Lisa
    Gorski, Matthew
    Angelilli, Allison
    Shih, Carolyn
    JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1119 - 1124
  • [27] The effect of corneal pathology on intraocular pressure measurement using the OBF pneumotonometer, Tonopen and Goldmann applanation tonometer.
    Browning, AC
    Bhan, A
    Shah, S
    Dua, HS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S282 - S282
  • [28] Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    Annette Lösch
    Alexander Scheuerle
    Volker Rupp
    Gerd Auffarth
    Matthias Becker
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 313 - 316
  • [29] THE COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT BY GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR PUFF TONOMETER: A CROSS-SECTIONAL RESEARCH
    Arooj, Bushra
    Nadeem, Asmarah
    Ali, Sobia
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (12): : 16875 - 16879
  • [30] Goldmann applanation tonometer error relative to true intracameral Intraocular pressure in vitro and in vivo
    McCafferty, Sean Joesph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)