DIAGNOSTIC PERFORMANCE - A COMPARATIVE-STUDY OF THE LEUKOCYTE DIFFERENTIAL COUNT ON 4 AUTOMATED HEMATOLOGY ANALYZERS

被引:0
|
作者
BUTTARELLO, M
LORENZ, C
GADOTTI, M
TOFFALORI, E
VALENTINI, A
RIZZOTTI, P
机构
[1] OSPED GERIATR,ANAL CHIMICOCLIN & MICROBIOL LAB,VIA VENDRAMINI 7,I-35100 PADUA,ITALY
[2] OSPED SANTA CHIARA,BIOCHIM & EMATOL LAB,TRENT,ITALY
[3] OSPED SANTA CHIARA,SERV FIS SANIT,TRENT,ITALY
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The diagnostic performance of the haematology analysers, Technicon H1, Sysmex NE 8000, Coulter STKS and Sequoia Cell Dyn 3000 was determined by comparing their results for automated differential counting with the result obtained for 400 cells by the manual microscopic method. These comparative studies were performed on a group of adults, containing both normal individuals (n = 150) and those affected by various pathologies (n = 113). The number of morphologically false negatives is low for all the systems (from 1.8% for the Cell Dyn 3000 to 6.2% for the NE 8000), while the number of distributionally false negatives was slightly higher (from 4.4% for the Cell Dyn 3000 to 7% for the H1 and NE 8000). The morphological flags, though useful for improving the diagnostic performance of the instruments, show a rather modest sensitivity when taken individually: immature granulocytes/bands from 71% for the STKS to 43% for the NE 8000; blasts from 66.6% for the H1 to 53.3% for the STKS, atypical lymphocytes from 59% for the H1 to 13.6% for the NE 8000; erythroblasts from 42.8% for the STKS to 7% for the NE 8000.
引用
收藏
页码:251 / 258
页数:8
相关论文
共 50 条
  • [31] Counting platelets in platelet concentrates on hematology analyzers: a multicenter comparative study
    van der Meer, Pieter F.
    Dijkstra-Tiekstra, Margriet J.
    Mahon, Anne
    de Wildt-Eggen, Janny
    TRANSFUSION, 2009, 49 (01) : 81 - 90
  • [32] Effective and Practical Complete Blood Count Delta Check Method and Criteria for the Quality Control of Automated Hematology Analyzers
    Kim, Min-Sun
    Park, Chan-Jeoung
    Namgoong, Seung
    Kim, Seung-Il
    Cho, Young-Uk
    Jang, Seongsoo
    ANNALS OF LABORATORY MEDICINE, 2023, 43 (05) : 418 - 424
  • [33] COMPARATIVE-STUDY OF 4 DIAGNOSTIC METHODS OF ENZOOTIC BOVINE LEUKOSIS
    MAMMERICKX, M
    BURNY, A
    DEKEGEL, D
    GHYSDAEL, J
    KETTMANN, R
    PORTETELLE, D
    ZENTRALBLATT FUR VETERINARMEDIZIN REIHE B-JOURNAL OF VETERINARY MEDICINE SERIES B-INFECTIOUS DISEASES IMMUNOLOGY FOOD HYGIENE VETERINARY PUBLIC HEALTH, 1977, 24 (09): : 733 - 740
  • [34] AUTOMATED HEMATOLOGY - A COMPARATIVE-STUDY OF CELL COUNTING AND SIZING USING APERTURE IMPEDANCE AND FLOW CYTOMETRIC SYSTEMS
    REARDON, DM
    HUTCHINSON, D
    BRADEY, L
    TROWBRIDGE, EA
    MEDICAL LABORATORY SCIENCES, 1987, 44 (04): : 320 - 325
  • [35] COMPARATIVE-STUDY OF AUTOMATED AND MANUAL PERIMETRY
    AULHORN, E
    DURST, W
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1988, 193 (04) : 431 - 432
  • [36] COMPARISON OF LEUKOCYTE DIFFERENTIATION CHANNELS OF AUTOMATED HEMATOLOGY ANALYZERS, XN-SERIES WDF AND XE-SERIES DIFF
    Wada, Atsushi
    Kawauchi, Sawako
    Takagi, Yuri
    Kono, Mari
    Morikawa, Takashi
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 137 - 137
  • [37] A COMPARATIVE-STUDY OF DIAGNOSTIC MODELING IN ELECTRODIAGNOSIS
    CAMPBELL, MG
    RUDOLFER, SM
    JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1982, 31 (01) : 97 - 106
  • [38] COMPARATIVE-STUDY OF HEMATOLOGY OF 3 AIR-BREATHING FISHES
    RAMASWAMY, M
    REDDY, TG
    PROCEEDINGS OF THE INDIAN ACADEMY OF SCIENCES SECTION B, 1978, 87 (12): : 381 - 385
  • [39] HEMATOLOGY ESTIMATION OF CD4 (T-HELPER) CELL COUNT USING AN AUTOMATED HEMATOLOGY ANALYZER
    IRANI, MS
    BANEZ, EI
    LABORATORY MEDICINE, 1990, 21 (11) : 746 - 748
  • [40] Comparative clinical study of canine and feline total blood cell count results with seven in-clinic and two commercial laboratory hematology analyzers
    Becker, Martina
    Moritz, Andreas
    Giger, Urs
    VETERINARY CLINICAL PATHOLOGY, 2008, 37 (04) : 373 - 384