A STANDARD TIMING BENCHMARK FOR EGS4 MONTE-CARLO CALCULATIONS

被引:29
|
作者
BIELAJEW, AF
ROGERS, DWO
机构
关键词
MONTE-CARLO; EGS (ELECTRON GAMMA-SHOWER); TIMING BENCHMARK;
D O I
10.1118/1.596860
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A Fortran 77 Monte Carlo source code built from the EGS4 Monte Carlo code system has been used for timing benchmark purposes on 29 different computers. This code simulates the deposition of energy from an incident electron beam in a 3-D rectilinear geometry such as one would employ to model electron and photon transport through a series of CT slices. The benchmark forms a standalone system and does not require that the EGS4 system be installed. The Fortran source code may be ported to different architectures by modifying a few lines and only a moderate amount of CPU time is required ranging from about 5 h on PC/386/387 to a few seconds on a massively parallel supercomputer (a BBN TC2000 with 512 processors).
引用
收藏
页码:303 / 304
页数:2
相关论文
共 50 条
  • [21] Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses
    Love, PA
    Lewis, DG
    Al-Affan, IAM
    Smith, CW
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05): : 1351 - 1357
  • [22] Anisotropy functions for low energy interstitial brachytherapy sources:: an EGS4 Monte Carlo study
    Capote, R
    Mainegra, E
    López, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01): : 135 - 150
  • [23] A NEW ELECTRON-TRANSPORT ALGORITHM FOR EGS MONTE-CARLO CALCULATIONS IN MEDICAL PHYSICS
    BIELAJEW, AF
    ROGERS, DWO
    MEDICAL PHYSICS, 1985, 12 (04) : 515 - 515
  • [24] Comparison of synchrotron radiation calculations between analytical codes (STAC8, PHOTON) and Monte Carlo codes (FLUKA, EGS4)
    Liu, JC
    Fasso, A
    Prinz, A
    Rokni, S
    Asano, Y
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 658 - 661
  • [25] The relative impact of scatter on absolute myocardial perfusion quantitation: An EGS4 Monte Carlo study
    Tang, HR
    Da Silva, AJ
    Hasegawa, BH
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1224 - 1228
  • [26] USE OF THE EGS4 MONTE-CARLO CODE TO EVALUATE THE RESPONSE OF HGI2 AND CDTE DETECTORS FOR PHOTONS IN THE DIAGNOSTIC ENERGY-RANGE
    CONTI, M
    DELGUERRA, A
    MAZZEI, D
    RUSSO, P
    BENCIVELLI, W
    BERTOLUCCI, E
    MESSINEO, A
    ROSSO, V
    STEFANINI, A
    BOTTIGLI, U
    RANDACCIO, P
    NELSON, WR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 591 - 595
  • [27] EGS4 Monte Carlo simulation of a 90° geometry polarized X-ray fluorescence system
    Fayez, HHA
    RADIATION PHYSICS AND CHEMISTRY, 1999, 55 (04) : 377 - 384
  • [28] MONTE-CARLO FIELD CALCULATIONS
    PICKLES, JH
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1977, 124 (12): : 1271 - 1276
  • [29] SYNCHROTRON-RADIATION CALCULATIONS USING THE EGS4 CODE
    LIU, JC
    NELSON, WR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (03): : 626 - 633
  • [30] Quantum Monte-Carlo calculations
    Lüchow, A
    NACHRICHTEN AUS DER CHEMIE, 2000, 48 (03) : 309 - 312