Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses

被引:32
|
作者
Love, PA [1 ]
Lewis, DG [1 ]
Al-Affan, IAM [1 ]
Smith, CW [1 ]
机构
[1] Velindre Hosp, Dept Med Phys, Cardiff CF4 7XL, S Glam, Wales
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 05期
关键词
D O I
10.1088/0031-9155/43/5/024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Monte Carlo codes EGS4 and MCNP have been compared when calculating radiotherapy depth doses in water. The aims of the work were to study (i) the differences between calculated depth doses in water for a range of monoenergetic photon energies and (ii) the relative efficiency of the two codes for different electron transport energy cut-offs. The depth doses from the two codes agree with each other within the statistical uncertainties of the calculations (1-2%). The relative depth doses also agree with data tabulated in the British Journal of Radiology Supplement 25. A discrepancy in the dose build-up region may by attributed to the different electron transport algorithms used by EGS4 and MCNP. This discrepancy is considerably reduced when the improved electron transport routines are used in the latest (4B) version of MCNP. Timing calculations show that EGS4 is at least 50% faster than MCNP for the geometries used in the simulations.
引用
收藏
页码:1351 / 1357
页数:7
相关论文
共 50 条
  • [1] Monte Carlo simulation of electron beams for radiotherapy - EGS4, MCNP4b and GEANT3 intercomparison
    Trindade, A
    Rodrigues, P
    Alves, C
    Chaves, A
    Lopes, MC
    Oliveira, C
    Peralta, L
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 311 - 316
  • [2] Comparison of EGS4 and MCNP4b Monte Carlo codes for generation of photon phase space distributions for a Varian 2100C
    Siebers, JV
    Keall, PJ
    Libby, B
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : 3009 - 3026
  • [3] Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources
    Chiavassa, S
    Lemosquet, A
    Aubineau-Lanièce, I
    de Carlan, L
    Clairand, I
    Ferrer, L
    Bardiès, M
    Franck, D
    Zankl, M
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 631 - 635
  • [4] Choosing $FUDGEMS in EGS4 Monte Carlo
    Werner, BL
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (04): : 735 - 743
  • [5] Monte Carlo Dose Calculations in Homogeneous and Heterogeneous Media: A Comparison between the PMCEPT code and the MCNP5, EGS4, DPM codes, and Experiments
    Kum, Oyeon
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1859 - 1862
  • [6] Monte Carlo dose calculations in homogeneous and heterogeneous media: A comparison between the PMCEPT code and the MCNP5, EGS4, DPM codes and measurements
    Kum, O.
    MEDICAL PHYSICS, 2006, 33 (06) : 2122 - 2122
  • [7] Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: A comparison between EGS4, EGSnrc, and MCNP
    Wang, RQ
    Li, XA
    MEDICAL PHYSICS, 2001, 28 (02) : 134 - 141
  • [8] Comparison of synchrotron radiation calculations between analytical codes (STAC8, PHOTON) and Monte Carlo codes (FLUKA, EGS4)
    Liu, JC
    Fasso, A
    Prinz, A
    Rokni, S
    Asano, Y
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 658 - 661
  • [9] An EGS4 Monte Carlo examination of general cavity theory
    Mobit, PN
    Nahum, AE
    Mayles, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (07): : 1319 - 1334
  • [10] A STANDARD TIMING BENCHMARK FOR EGS4 MONTE-CARLO CALCULATIONS
    BIELAJEW, AF
    ROGERS, DWO
    MEDICAL PHYSICS, 1992, 19 (02) : 303 - 304