Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses

被引:32
|
作者
Love, PA [1 ]
Lewis, DG [1 ]
Al-Affan, IAM [1 ]
Smith, CW [1 ]
机构
[1] Velindre Hosp, Dept Med Phys, Cardiff CF4 7XL, S Glam, Wales
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 05期
关键词
D O I
10.1088/0031-9155/43/5/024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Monte Carlo codes EGS4 and MCNP have been compared when calculating radiotherapy depth doses in water. The aims of the work were to study (i) the differences between calculated depth doses in water for a range of monoenergetic photon energies and (ii) the relative efficiency of the two codes for different electron transport energy cut-offs. The depth doses from the two codes agree with each other within the statistical uncertainties of the calculations (1-2%). The relative depth doses also agree with data tabulated in the British Journal of Radiology Supplement 25. A discrepancy in the dose build-up region may by attributed to the different electron transport algorithms used by EGS4 and MCNP. This discrepancy is considerably reduced when the improved electron transport routines are used in the latest (4B) version of MCNP. Timing calculations show that EGS4 is at least 50% faster than MCNP for the geometries used in the simulations.
引用
收藏
页码:1351 / 1357
页数:7
相关论文
共 50 条
  • [21] CALCULATION OF BETA DOSIMETRY IN RADIATION SYNOVECTOMY USING MONTE-CARLO SIMULATION (EGS4)
    JOHNSON, LS
    YANCH, JC
    MEDICAL PHYSICS, 1993, 20 (03) : 747 - 754
  • [22] Response calculation for standard ionization chambers in the APMP using EGS4 Monte Carlo code
    Sato, Yasushi
    Yunoki, Akira
    Hino, Yoshio
    Yamada, Takahiro
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1211 - 1214
  • [23] The relative impact of scatter on absolute myocardial perfusion quantitation: An EGS4 Monte Carlo study
    Tang, HR
    Da Silva, AJ
    Hasegawa, BH
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1224 - 1228
  • [24] The dose distribution close to an Ir-192 wire source: EGS4 Monte Carlo calculations
    Cheung, YC
    Yu, PKN
    Young, ECM
    Chan, CL
    Ng, MF
    Tang, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02): : 401 - 406
  • [25] EGS4 Monte Carlo simulation of a 90° geometry polarized X-ray fluorescence system
    Fayez, HHA
    RADIATION PHYSICS AND CHEMISTRY, 1999, 55 (04) : 377 - 384
  • [26] Dose distributions at extreme irradiation depths of gamma knife radiosurgery: EGS4 Monte Carlo calculations
    Cheung, JYC
    Yu, KN
    Yu, CP
    Ho, RTK
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (03) : 461 - 465
  • [27] Comparison of MCNP4C and EGSnrc Monte Carlo codes in depth-dose calculation of low energy clinical electron beams
    Jabbari, N.
    Hashemi-Malayeri, B.
    Farajollahi, A. R.
    Kazemnejad, A.
    Shafaei, A.
    Jabbari, S.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (15) : 4519 - 4524
  • [28] AN EVALUATION OF THE EGS4 AND CYLTRAN MONTE-CARLO CODES WITH REGARD TO BOUNDARY BETA-RAY DOSIMETRY BY COMPARISON WITH EXPERIMENTAL BETA-RAY DOSE BACKSCATTER FACTORS
    NUNES, J
    PRESTWICH, WV
    KWOK, CS
    MEDICAL PHYSICS, 1993, 20 (04) : 1243 - 1250
  • [29] Calculation of energy response of cylindrical G-M tubes with EGS4 Monte Carlo code
    Liu, BX
    Wang, YC
    Xie, B
    Zhang, H
    PROCEEDINGS OF CHEP 2001, 2001, : 354 - 356
  • [30] Monte Carlo simulation of mammography X-ray units:: A comparison between different electron extensions of the EGS4 code system
    Marziani, M
    Gambaccini, M
    Távora, LMN
    Taibi, A
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 351 - 356