A STANDARD TIMING BENCHMARK FOR EGS4 MONTE-CARLO CALCULATIONS

被引:29
|
作者
BIELAJEW, AF
ROGERS, DWO
机构
关键词
MONTE-CARLO; EGS (ELECTRON GAMMA-SHOWER); TIMING BENCHMARK;
D O I
10.1118/1.596860
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A Fortran 77 Monte Carlo source code built from the EGS4 Monte Carlo code system has been used for timing benchmark purposes on 29 different computers. This code simulates the deposition of energy from an incident electron beam in a 3-D rectilinear geometry such as one would employ to model electron and photon transport through a series of CT slices. The benchmark forms a standalone system and does not require that the EGS4 system be installed. The Fortran source code may be ported to different architectures by modifying a few lines and only a moderate amount of CPU time is required ranging from about 5 h on PC/386/387 to a few seconds on a massively parallel supercomputer (a BBN TC2000 with 512 processors).
引用
收藏
页码:303 / 304
页数:2
相关论文
共 50 条
  • [31] EGS4 dosimetry calculations for cylindrically symmetric brachytherapy sources
    Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alta. T6G 1Z2, Canada
    MED. PHYS., 8 (1459-1465):
  • [32] Benchmark quantum Monte Carlo calculations
    Grossman, JC
    JOURNAL OF CHEMICAL PHYSICS, 2002, 117 (04): : 1434 - 1440
  • [33] Calculation of energy response of cylindrical G-M tubes with EGS4 Monte Carlo code
    Liu, BX
    Wang, YC
    Xie, B
    Zhang, H
    PROCEEDINGS OF CHEP 2001, 2001, : 354 - 356
  • [34] EGS4 dosimetry calculations for cylindrically symmetric brachytherapy sources
    Wang, RQ
    Sloboda, RS
    MEDICAL PHYSICS, 1996, 23 (08) : 1459 - 1465
  • [35] An EGS4 based Monte Carlo code for the calculation of organ equivalent dose to a modified Yale voxel phantom
    Kramer, R
    Vieira, JW
    Lima, FRA
    Fuelle, D
    CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (05) : 465 - 473
  • [36] Application of unfolding technique to HPGe detector using response functions calculated with the EGS4 Monte Carlo code
    Chun, KJ
    Hah, SH
    Kim, HM
    Yoo, GH
    JOURNAL OF RADIATION RESEARCH, 2006, 47 (01) : 27 - 40
  • [37] Monte Carlo dose calculations in homogeneous and heterogeneous media: A comparison between the PMCEPT code and the MCNP5, EGS4, DPM codes and measurements
    Kum, O.
    MEDICAL PHYSICS, 2006, 33 (06) : 2122 - 2122
  • [38] DOSIMETRIC MEASUREMENTS BEHIND INHOMOGENEITIES EXPOSED TO ELECTRON-BEAMS AND COMPARISONS TO EGS MONTE-CARLO CALCULATIONS
    SHORTT, KR
    ROSS, CK
    BIELAJEW, AF
    ROGERS, DWO
    MEDICAL PHYSICS, 1985, 12 (04) : 508 - 508
  • [39] Monte Carlo Dose Calculations in Homogeneous and Heterogeneous Media: A Comparison between the PMCEPT code and the MCNP5, EGS4, DPM codes, and Experiments
    Kum, Oyeon
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1859 - 1862
  • [40] A Monte-Carlo Benchmark of TRIPOLI-4® and MCNP on ITER neutronics
    Blanchet, David
    Peneliau, Yannick
    Eschbach, Romain
    Fontaine, Bruno
    Cantone, Bruno
    Ferlet, Marc
    Gauthier, Eric
    Guillon, Christophe
    Letellier, Laurent
    Proust, Maxime
    Mota, Fernando
    Palermo, Iole
    Rios, Luis
    Le Guern, Frederic
    Kocan, Martin
    Reichle, Roger
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153