SYNCHROTRON RADIATION CORONARY ANGIOGRAPHY WITH A DUAL-BEAM, DUAL-DETECTOR IMAGING-SYSTEM

被引:24
|
作者
RUBENSTEIN, E
GIACOMINI, JC
GORDON, HJ
THOMPSON, AC
BROWN, G
HOFSTADTER, R
THOMLINSON, W
ZEMAN, HD
机构
[1] UNIV CALIF BERKELEY LAWRENCE BERKELEY LAB,BERKELEY,CA 94720
[2] STANFORD UNIV,STANFORD SYNCHROTRON RADIAT LAB,STANFORD,CA 94305
[3] STANFORD UNIV,DEPT PHYS,STANFORD,CA 94305
[4] BROOKHAVEN NATL LAB,NATL SYNCHROTRON LIGHT SOURCE,UPTON,NY 11973
基金
美国国家卫生研究院;
关键词
D O I
10.1016/0168-9002(90)90037-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This is a study of the use of a dual-beam, dual-detector synchrotron radiation system for transvenous coronary angiography in a human subject. This system eliminates the need for rapid beam switching, increases X-ray fluence by a factor of about 2.5, and makes it possible to record high- and low-energy images simultaneously, thus excluding artifacts arising from time subtraction. Besides coronary angiography, it may be possible to image the vertebral-basilar arterial circulation with this system. © 1990.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 50 条
  • [21] Extended Commissioning and Calibration of the Dual-Beam Imaging Polarimeter
    Masiero, J.
    Hodapp, K.
    Harrington, D.
    Lin, H.
    ASTRONOMICAL POLARIMETRY 2008: SCIENCE FROM SMALL TO LARGE TELESCOPES, 2011, 449 : 39 - 43
  • [22] SOME LIMITATIONS OF DUAL-BEAM SELECTIVE IODINE IMAGING
    RIEDERER, SJ
    KRUGER, RA
    MISTRETTA, CA
    MEDICAL PHYSICS, 1980, 7 (04) : 434 - 434
  • [23] Dual-detector polarimetry for compensation of motion artifact in a glucose sensing system
    Baba, JS
    Coté, GL
    OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING II, 2002, 4624 : 76 - 80
  • [24] Dual-Beam Periodic Leaky Wave Antenna with Broadside Radiation
    Shaw, Ravi
    Mandal, Mrinal Kanti
    2016 ASIA-PACIFIC MICROWAVE CONFERENCE (APMC2016), 2016,
  • [25] A DUAL LINE MULTICELL IONIZATION-CHAMBER FOR TRANSVENOUS CORONARY ANGIOGRAPHY WITH SYNCHROTRON-RADIATION
    MENK, RH
    DIX, WR
    GRAEFF, W
    ILLING, G
    REIME, B
    SCHILDWACHTER, L
    TAFELMEIER, U
    BESCH, HJ
    GROSSMANN, U
    LANGER, R
    LOHMANN, M
    SCHENK, HW
    WAGENER, M
    WALENTA, AH
    KUPPER, W
    HAMM, C
    RUST, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2327 - 2329
  • [26] VERSATILE ECHO SOUNDING SYSTEM USING DUAL-BEAM
    FURUSAWA, M
    TAKAO, Y
    SAWADA, K
    OKUBO, T
    YAMATANI, K
    NIPPON SUISAN GAKKAISHI, 1993, 59 (06) : 967 - 980
  • [27] Dual-beam potassium Voigt filter for atomic line imaging
    Kudenov, Michael W.
    Pantalone, Brett
    Yang, Ruonan
    APPLIED OPTICS, 2020, 59 (17) : 5282 - 5289
  • [28] IODINE K-EDGE DUAL-ENERGY IMAGING FOR SUBTRACTION ANGIOGRAPHY USING SYNCHROTRON RADIATION AND A 2-DIMENSIONAL DETECTOR
    UMETANI, K
    UEDA, K
    TAKEDA, T
    AKISADA, M
    NAKAJIMA, T
    ANNO, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 301 (03): : 579 - 588
  • [29] Dual-beam imaging for online verification of radiotherapy field placement
    Jaffray, DA
    Chawla, K
    Yu, C
    Wong, JW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1273 - 1280
  • [30] Dual-detector X-ray fluorescence imaging of ancient artifacts with surface relief
    Smilgies, Detlef-M.
    Powers, Judson A.
    Bilderback, Donald H.
    Thorne, Robert E.
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 547 - 550