Dual-detector polarimetry for compensation of motion artifact in a glucose sensing system

被引:4
|
作者
Baba, JS [1 ]
Coté, GL [1 ]
机构
[1] Texas A&M Univ, Biomed Engn Program, College Stn, TX 77843 USA
关键词
diabetes mellitus; aqueous humor; birefringence; motion artifact; glucose measurement;
D O I
10.1117/12.468329
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Much work has been done to make the optical measurement of glucose concentrations in the aqueous humor a feasible, non-invasive, alternative for the blood finger stick method currently used by people with diabetes mellitus. Recent work has demonstrated that the time lag between blood and aqueous humor glucose levels is within five minutes but there is still work to be done in overcoming the confounding effects of changing birefringence, due to motion artifact, on the detected glucose signal during in-vivo measurements. To address this issue, we designed and implemented a dual orthogonal polarization detection system. We present promising preliminary results that indicate that this method, with some slight modifications and optimization of our system, has the potential to extract glucose concentration information from a birefringent sample in the presence of motion artifact.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [1] Molecular Breast Imaging Biopsy with a Dual-Detector System
    Hunt, Katie N.
    Conners, Amy Lynn
    Gray, Lacey
    Hruska, Carrie B.
    O'Connor, Michael K.
    RADIOLOGY-IMAGING CANCER, 2024, 6 (04): : e230186
  • [2] A dual-detector based optical fluorescence imaging system
    Chen, JY
    Li, YH
    Liu, H
    Complex Dynamics and Fluctuations in Biomedical Photonics II, 2005, 5696 : 110 - 116
  • [3] ESTIMATION OF OPIATE RECEPTOR OCCUPANCY USING A DUAL-DETECTOR SYSTEM
    LEE, MC
    BICE, AN
    WAGNER, HN
    FROST, JJ
    NATARAJAN, TK
    DANNALS, RF
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 945 - 945
  • [4] Motion compensation for detecting glucose through dual wavelength polarimetric system
    Dixon, JB
    Wan, QJ
    Coté, GL
    Optical Diagnostics and Sensing V, 2005, 5702 : 15 - 22
  • [5] Synchrotron radiation coronary angiography with a dual-beam dual-detector imaging system
    1600, Publ by Elsevier Science Publ BV (North-Holland), Amsterdam, Neth (291): : 1 - 2
  • [6] Real-time Dual Wavelength Polarimetry for Glucose Sensing
    Malik, Bilal H.
    Cote, Gerard L.
    OPTICAL DIAGNOSTICS AND SENSING IX, 2009, 7186
  • [7] Noise Power Properties of a Dual-Detector Cone-Beam CT System
    Li, H.
    Giles, W.
    Roper, J.
    Bowsher, J.
    Yin, F.
    MEDICAL PHYSICS, 2011, 38 (06) : 3373 - +
  • [8] SYNCHROTRON RADIATION CORONARY ANGIOGRAPHY WITH A DUAL-BEAM, DUAL-DETECTOR IMAGING-SYSTEM
    RUBENSTEIN, E
    GIACOMINI, JC
    GORDON, HJ
    THOMPSON, AC
    BROWN, G
    HOFSTADTER, R
    THOMLINSON, W
    ZEMAN, HD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2): : 80 - 85
  • [9] Stokes-Mueller matrix polarimetry system for glucose sensing
    Quoc-Hung Phan
    Lo, Yu-Lung
    OPTICS AND LASERS IN ENGINEERING, 2017, 92 : 120 - 128
  • [10] Development of a dual-detector X-ray imaging system for phase retrieval study
    Meng, Fanbo
    Yan, Aimin
    Zhou, Ge
    Wu, Xizeng
    Liu, Hong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 254 (02): : 300 - 306