Dual-detector polarimetry for compensation of motion artifact in a glucose sensing system

被引:4
|
作者
Baba, JS [1 ]
Coté, GL [1 ]
机构
[1] Texas A&M Univ, Biomed Engn Program, College Stn, TX 77843 USA
关键词
diabetes mellitus; aqueous humor; birefringence; motion artifact; glucose measurement;
D O I
10.1117/12.468329
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Much work has been done to make the optical measurement of glucose concentrations in the aqueous humor a feasible, non-invasive, alternative for the blood finger stick method currently used by people with diabetes mellitus. Recent work has demonstrated that the time lag between blood and aqueous humor glucose levels is within five minutes but there is still work to be done in overcoming the confounding effects of changing birefringence, due to motion artifact, on the detected glucose signal during in-vivo measurements. To address this issue, we designed and implemented a dual orthogonal polarization detection system. We present promising preliminary results that indicate that this method, with some slight modifications and optimization of our system, has the potential to extract glucose concentration information from a birefringent sample in the presence of motion artifact.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [31] Development of a dual-detector system based on a-Si:H Arrays and multi-element silicon detectors for diffraction-enhanced breast imaging
    Darambara, DG
    Speller, RD
    Sellin, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1012 - 1016
  • [32] Humidity compensation of bad-smell sensing system using a detector tube and a built-in camera
    Hirano, Hiroyuki
    Nakamoto, Takamichi
    OLFACTION AND ELECTRONIC NOSE: PROCEEDINGS OF THE 14TH INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE, 2011, 1362 : 79 - 80
  • [33] Subjective and objective comparison of advanced motion compensation methods for blocking artifact reduction in a 3-D wavelet coding system
    Cheng, Cho-Chun
    Hwang, Wen-Liang
    Shen, Zuowei
    Xia, Tao
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2006, 16 (09) : 1134 - 1141
  • [34] DUAL-DETECTOR POST-COLUMN REACTOR SYSTEM FOR THE DETECTION OF ISOENZYMES SEPARATED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. DESCRIPTION AND THEORY
    FULTON, JA
    SCHLABACH, TD
    KERL, JE
    TOREN, EC
    MILLER, AR
    JOURNAL OF CHROMATOGRAPHY, 1979, 175 (02): : 269 - 281
  • [35] First Implementation of High-Resolution Dual-Detector RegionOf- Interest Cone-Beam Computed Tomography (ROI-CBCT) for a Rotating CArm Gantry System
    Patel, V.
    Ionita, C.
    Keleshis, C.
    Sherman, J.
    Hoffmann, K.
    Bednarek, D.
    Rudin, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [36] Humidity Compensation by Neural Network for Bad-Smell Sensing System Using Gas Detector Tube and Built-in Camera
    Nakamoto, T.
    Ikeda, T.
    Hirano, H.
    Arimoto, T.
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 281 - +
  • [37] Humidity Compensation by Neural Network for Bad-Smell Sensing System Using Gas Detector Tube and Built-in Camera
    Nakamoto, Takamichi
    Ikeda, Tomohiro
    Hirano, Hiroyuki
    Arimoto, Takemi
    SENSORS AND MATERIALS, 2011, 23 (01) : 71 - 85
  • [38] Reconstruction of truncated projection data from an L-shaped dual detector system for attenuation compensation in myocardial SPECT.
    Tsui, BMW
    Lewis, DP
    Lalush, DS
    Lonn, AHR
    Maniam, S
    Culp, R
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 954 - 954
  • [39] A double-layered liquid metal-based electrochemical sensing system on fabric as a wearable detector for glucose in sweat
    Xuanqi Chen
    Hao Wan
    Rui Guo
    Xinpeng Wang
    Yang Wang
    Caicai Jiao
    Kang Sun
    Liang Hu
    Microsystems & Nanoengineering, 8
  • [40] A double-layered liquid metal-based electrochemical sensing system on fabric as a wearable detector for glucose in sweat
    Chen, Xuanqi
    Wan, Hao
    Guo, Rui
    Wang, Xinpeng
    Wang, Yang
    Jiao, Caicai
    Sun, Kang
    Hu, Liang
    MICROSYSTEMS & NANOENGINEERING, 2022, 8 (01)