SYNCHROTRON RADIATION CORONARY ANGIOGRAPHY WITH A DUAL-BEAM, DUAL-DETECTOR IMAGING-SYSTEM

被引:24
|
作者
RUBENSTEIN, E
GIACOMINI, JC
GORDON, HJ
THOMPSON, AC
BROWN, G
HOFSTADTER, R
THOMLINSON, W
ZEMAN, HD
机构
[1] UNIV CALIF BERKELEY LAWRENCE BERKELEY LAB,BERKELEY,CA 94720
[2] STANFORD UNIV,STANFORD SYNCHROTRON RADIAT LAB,STANFORD,CA 94305
[3] STANFORD UNIV,DEPT PHYS,STANFORD,CA 94305
[4] BROOKHAVEN NATL LAB,NATL SYNCHROTRON LIGHT SOURCE,UPTON,NY 11973
基金
美国国家卫生研究院;
关键词
D O I
10.1016/0168-9002(90)90037-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This is a study of the use of a dual-beam, dual-detector synchrotron radiation system for transvenous coronary angiography in a human subject. This system eliminates the need for rapid beam switching, increases X-ray fluence by a factor of about 2.5, and makes it possible to record high- and low-energy images simultaneously, thus excluding artifacts arising from time subtraction. Besides coronary angiography, it may be possible to image the vertebral-basilar arterial circulation with this system. © 1990.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 50 条
  • [31] Choroidal imaging by one-micrometer dual-beam Doppler optical coherence angiography with adjustable velocity range
    Jaillon, Franck
    Makita, Shuichi
    Yasuno, Yoshiaki
    OPHTHALMIC TECHNOLOGIES XXII, 2012, 8209
  • [32] Assessment of knee cartilage in cadavers with dual-detector spiral CT arthrography and MR imaging
    Vande Berg, BC
    Lecouvet, FE
    Poilvache, P
    Jamart, J
    Materne, R
    Lengele, B
    Maldague, B
    Malghem, J
    RADIOLOGY, 2002, 222 (02) : 430 - 436
  • [33] Investigation of 90° dual-detector half-fanbeam collimation for myocardial SPECT imaging
    LaCroix, Karen J.
    Tsui, Benjamin M.W.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1189 - 1193
  • [34] Improvement of the metrological performance stability of a dual-beam optical system
    Jokhovets, LV
    Domanevskii, DS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (05) : 711 - 712
  • [35] Smart modular lighting control system with dual-beam luminaires
    Caicedo, D.
    Pandharipande, A.
    Vissenberg, M. C. J. M.
    LIGHTING RESEARCH & TECHNOLOGY, 2015, 47 (04) : 389 - 404
  • [36] Improvement of the Metrological Performance Stability of a Dual-Beam Optical System
    L. V. Jokhovets
    D. S. Domanevskii
    Instruments and Experimental Techniques, 2002, 45 : 711 - 712
  • [37] Nondestructive Characterization of Thin Film System with Dual-Beam Interferometer
    Park, Hae-Sung
    Didie, David
    Didie, Daniel
    Yoshida, Sanichiro
    Park, Ik-Keun
    Cho, Seung Bum
    Sasaki, Tomohiro
    RESIDUAL STRESS, THERMOMECHANICS & INFRARED IMAGING, HYBRID TECHNIQUES AND INVERSE PROBLEMS, VOL 9, 2016, : 129 - 137
  • [38] SURFACE PROFILE MEASUREMENT WITH A DUAL-BEAM OPTICAL-SYSTEM
    LOU, DY
    MARTINEZ, A
    STANTON, D
    APPLIED OPTICS, 1984, 23 (05): : 746 - 751
  • [39] LOW-NOISE AMPLIFYING SYSTEM FOR DUAL-BEAM SPECTROPHOTOMETERS
    LARKINS, PL
    MELDRUM, JR
    AUSTRALIAN JOURNAL OF INSTRUMENTATION & CONTROL, 1974, 30 (05): : 12 - 16
  • [40] Dual-beam laser autofocusing system based on liquid lens
    Zhang, Fumin
    Yao, Yannan
    Qu, Xinghua
    Zhang, Tong
    Pei, Bing
    OPTICS AND LASER TECHNOLOGY, 2017, 88 : 198 - 204