ACTIVE CURRENT ELECTRODES FOR IN-VIVO ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:20
|
作者
JOSSINET, J
TOURTEL, C
JARRY, R
机构
[1] Inst. Nat. de la Sante et de la Recherche Medicale, Lyon
关键词
D O I
10.1088/0967-3334/15/2A/012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The characterization of tissue by means of electrical impedance tomography requires accurate impedance measurements at relatively high frequencies. The present study describes the design and fabrication of broad-band, active, current electrodes for in vivo measurements. This approach eliminates the lead capacitances of the sourcing electrodes. The value of the resistors used were computed according to a protocol taking into account the constraints of a given application and the values and tolerances of the available components. Additional selection of the components further reduced the variability in circuit performance. The current sources designed according to the method described are usable at frequencies higher than 1 MHz, for differential load impedances up to 2000 OMEGA. The parallel output conductance for each active electrode is 0.85 muS+/-2%. The design method is valid for either adjacent or diametric drive, and can be applied to various applications by modifying the shape of the electrode.
引用
收藏
页码:A83 / A90
页数:8
相关论文
共 50 条
  • [41] CONDUCTIVITY AND PERMITTIVITY IMAGES FROM AN INDUCED CURRENT ELECTRICAL-IMPEDANCE TOMOGRAPHY SYSTEM
    SCAIFE, JM
    TOZER, RC
    FREESTON, IL
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1994, 141 (05) : 356 - 362
  • [42] WALSH-FUNCTION CURRENT PATTERNS AND DATA SYNTHESIS FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    WOO, EJ
    HUA, P
    WEBSTER, JG
    TOMPKINS, WJ
    PALLASARENY, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (04) : 554 - 559
  • [43] RECOMBINATION IN SEMICONDUCTOR ELECTRODES - INVESTIGATION BY THE ELECTRICAL-IMPEDANCE METHOD
    VANMAEKELBERGH, D
    CARDON, F
    ELECTROCHIMICA ACTA, 1992, 37 (05) : 837 - 846
  • [44] COMMON-MODE FEEDBACK IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    ROSELL, J
    RIU, P
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 11 - 14
  • [45] IMAGE-RECONSTRUCTION PROBLEMS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BARBER, DC
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (02): : 181 - 182
  • [46] ITERATIVE RECONSTRUCTION METHODS USING REGULARIZATION AND OPTIMAL CURRENT PATTERNS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    HUA, P
    WOO, EJ
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) : 621 - 628
  • [47] A WIDE-BAND AC-COUPLED CURRENT SOURCE FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BRAGOS, R
    ROSELL, J
    RIU, P
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : A91 - A99
  • [48] THE SPECTRAL EXPANSION OF A HEAD MODEL IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    ZADEHKOOCHAK, M
    BLOTT, BH
    HAMES, TK
    GEORGE, RF
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 : 101 - 105
  • [49] NEURAL NETWORKS FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY IMAGE CHARACTERIZATION
    MILLER, AS
    BLOTT, BH
    HAMES, TK
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 119 - 123
  • [50] ELECTRICAL-IMPEDANCE TOMOGRAPHY SYSTEMS BASED ON VOLTAGE DRIVE
    SANSEN, W
    GEERAERTS, B
    VANPETEGEM, W
    STEYAERT, M
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 39 - 42