ACTIVE CURRENT ELECTRODES FOR IN-VIVO ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:20
|
作者
JOSSINET, J
TOURTEL, C
JARRY, R
机构
[1] Inst. Nat. de la Sante et de la Recherche Medicale, Lyon
关键词
D O I
10.1088/0967-3334/15/2A/012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The characterization of tissue by means of electrical impedance tomography requires accurate impedance measurements at relatively high frequencies. The present study describes the design and fabrication of broad-band, active, current electrodes for in vivo measurements. This approach eliminates the lead capacitances of the sourcing electrodes. The value of the resistors used were computed according to a protocol taking into account the constraints of a given application and the values and tolerances of the available components. Additional selection of the components further reduced the variability in circuit performance. The current sources designed according to the method described are usable at frequencies higher than 1 MHz, for differential load impedances up to 2000 OMEGA. The parallel output conductance for each active electrode is 0.85 muS+/-2%. The design method is valid for either adjacent or diametric drive, and can be applied to various applications by modifying the shape of the electrode.
引用
收藏
页码:A83 / A90
页数:8
相关论文
共 50 条
  • [21] A SENSITIVITY METHOD FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BARBER, DC
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (04): : 368 - 370
  • [22] OPTIMAL ELECTROLYTIC CHLORIDING OF SILVER INK ELECTRODES FOR USE IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    MCADAMS, ET
    HENRY, P
    MCCANDERSON, J
    JOSSINET, J
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 19 - 23
  • [23] A ONE OP-AMP CURRENT SOURCE FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    NOWICKI, DJ
    WEBSTER, JG
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 457 - 458
  • [24] Electrical impedance tomography system based on active electrodes
    Gaggero, Pascal Olivier
    Adler, Andy
    Brunner, Josef
    Seitz, Peter
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (05) : 831 - 847
  • [25] AN ELECTRICAL-IMPEDANCE TOMOGRAPH USING COMPOUND ELECTRODES
    HUA, P
    WOO, EJ
    WEBSTER, JG
    TOMPKINS, WJ
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 472 - 473
  • [26] ON THE SENSITIVITY METHOD OF RECONSTRUCTION FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    GADD, R
    RECORD, PM
    ROLFE, P
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (02): : 180 - 181
  • [27] SPECTRAL EXPANSION ANALYSIS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    ZADEHKOOCHAK, M
    BLOTT, BH
    HAMES, TK
    GEORGE, RF
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1991, 24 (11) : 1911 - 1916
  • [28] OPTIMIZING THE TIME TO SOLUTION IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    FULTON, WS
    LIPCZYNSKI, RT
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1995, 142 (06) : 433 - 441
  • [29] DETECTION OF GASTROESOPHAGEAL REFLUX BY ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RAVELLI, AM
    MILLA, PJ
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1994, 18 (02): : 205 - 213
  • [30] ELECTRICAL-IMPEDANCE TOMOGRAPHY USING INDUCED CURRENTS
    GENCER, NG
    KUZUOGLU, M
    IDER, YZ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) : 338 - 350